- Home /
- Search /
- Mesa /
- Best Plumbers in Mesa
Updated: Feb 04, 2026
Location and Projects
Address
2622 N Ogden, Mesa, AZ, 85215
Use our bidding system to
request a quote
Kerns plumbing LLC
Kerns plumbing LLC, 2622 N Ogden, Mesa, AZ holds a Specialty Dual license according to the Arizona license board.
Their BuildZoom score of 0 does not rank in the top 50% of Arizona contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Kerns plumbing LLC, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Kerns plumbing LLC Mesa
Quality
Alert*
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
*No active license on file. If you are Kerns plumbing LLC, log in and update your license info in the “Edit Profile” tab.
Activity
|
361 projects
|
2025 |
|
508 projects
|
2024 |
|
1373 projects
|
2023 |
Our building permit records indicate that Kerns plumbing LLC has worked on at least
2242.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
43 projects
|
Commercial Renovations |
|
9 projects
|
Home Additions |
|
897 projects
|
Plumbing projects |
|
15 projects
|
Sewer laterals |
Analyzing permits over the last 4 years shows that Kerns plumbing LLC mostly works on
plumbing project
and commercial renovation
projects.
Pricing
|
542 projects
|
< $5k |
|
179 projects
|
$5k-$20k |
|
33 projects
|
$20k-$50k |
|
1 project
|
$50k-$100k |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Effective building codes: 2024 ibc 2024 irc 2024 imc 2024 iecc 2024 ipc 2024 upc 2024 ifgc 2024 iebc 2024 ispsc 2023 nec and 2018 phx fire code description of work: 131 l.f. of 1-1/4 pe line 18 deep w/tracer wire from meter to 100k btu fire pit and 75k btu bbq. no other appliances listed on line reviewer: res: mbail site: na - hillside is inv note: carbon monoxide alarms are required ... see more
Valuation:
$500
Permit #:
CTR-102508563
Status:
issued
Fee:
$270
Permit Type:
Repairs replacements
Building Type:
Single family
Gas line from meter to bbq and fire pits effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of total 152 l.f. of p.e. gas line buried to a 75k btu bbq 75k btu fire pit and 75k btu second fire pit using approved gas pipe per current plumbing code regulations note: carbon monoxide alar... see more
Valuation:
$500
Permit #:
CTR-102506197
Status:
issued
Fee:
$279
Permit Type:
Repairs replacements
Building Type:
Single family
Revision #1 to ctr-102412068 installation of 152 lf of 2 pe pipe from the gas meter to 400k btu pool heater using approved gas pipe per current plumbing code regulations effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code reviewer: sosor new description of work: installation of 152 lf of 2 pe pipe from the gas meter t... see more
Valuation:
$500
Permit #:
RVSN-102412068-01
Status:
approved
Fee:
$75
Permit Type:
Revision to appro...
Building Type:
Single family
1st revision - addition of bbq to increase total development length to 193 lf effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of 75 l.f. of 2 pe gas line 85 l.f. of 2 pe gas line buried to a 400k btu pool heater and 30 l.f. of 3/4 pe gas line buried to a 75k btu fire pit addition ... see more
Valuation:
$500
Permit #:
RVSN-102504596-01
Status:
approved
Fee:
$75
Permit Type:
Revision to appro...
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code reviewer: sosor description of work: installation of 13 lf of 1-1/2 33 lf of 3/4 and 10 lf of 3/4 bi pe pipe from the gas meter to 400k btu pool heater and 75k btu fire pit using approved gas pipe per current plumbing code regulations ********************************... see more
Valuation:
$500
Permit #:
CTR-102505505
Status:
final
Fee:
$243
Permit Type:
Repairs replacements
Building Type:
Single family
Gas line from meter to pool heater and bbq effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of approx 69 l.f. of 1 1/2 p.e. gas line buried to a 50k btu bbq and 400k btu pool heater using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are requi... see more
Valuation:
$500
Permit #:
CTR-102505460
Status:
final
Fee:
$168
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: gas line from meter to pool heater gas line 100 ft of 1 1/2 galv pipe buried to a 400k btu using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required for new/remodel construction when fuel fired applia... see more
Valuation:
$500
Permit #:
CTR-102504911
Status:
final
Fee:
$252
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of 144’ l.f. of 2 p.e. gas line 44’ of 1” p.e. gas line buried 18” with #18 gauge insulated tracer wire from meter to 400k btu pool heater 75k btu bbq and 50k btu firepit using approved gas pipe per current plumbing code regulations ... see more
Valuation:
$500
Permit #:
CTR-102504608
Status:
final
Fee:
$213
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of 50’ l.f. of 1 14 p.e. gas line buried 18” with #18 gauge insulated tracer wire from meter to 400k btu pool heater using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required for new/remo... see more
Valuation:
$500
Permit #:
CTR-102505090
Status:
final
Fee:
$159
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of 41 l.f. of p.e. gas line buried to a 400k btu pool heater using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required for new/remodel construction when fuel fired appliances are installe... see more
Valuation:
$500
Permit #:
CTR-102505002
Status:
final
Fee:
$234
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: 46 of 1.25 of pe gas line from meter to 65k btu bbq burried 18 with 18 ga tracer wire using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required for new/remodel construction when fuel fired appliances ... see more
Valuation:
$500
Permit #:
CTR-102502336
Status:
final
Fee:
$159
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code scope of work: reroute replace 30 lf of 4 abs sewer pipe out of pool footprint hillside: no flood plain: no historic: no zoning: r1-6 reviewer: fmont
Valuation:
$500
Permit #:
CTR-102504878
Status:
final
Fee:
$150
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: 30 lf of 2 pe gas line from meter to 250k btu pool heater burried 18 with 18 ga tracer wire using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required for new/remodel construction when fuel fired appli... see more
Valuation:
$500
Permit #:
CTR-102504551
Status:
final
Fee:
$159
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of 115 l.f. of 1-1/2 p.e. gas line buried to pool heater a 400k btu using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required for new/remodel construction when fuel fired appliances are i... see more
Valuation:
$500
Permit #:
CTR-102504710
Status:
issued
Fee:
$186
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of 34 l.f. of p.e. pipe from gas meter (fire permit#) to; a 400k btu pool heater. using approved gas pipe per current plumbing code regulations. reviewer: phid note: carbon monoxide alarms are required for new/remodel construction wh... see more
Valuation:
$500
Permit #:
CTR-102504647
Status:
final
Fee:
$159
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: 177 lf of 2 pe gas line from meter to 400k btu pool heater burried 18 below grade with 18 ga tracer wire using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required for new/remodel construction when fue... see more
Valuation:
$500
Permit #:
CTR-102504105
Status:
final
Fee:
$204
Permit Type:
Repairs replacements
Building Type:
Single family
1st revision - updated plan to show all appliances and increased new pe pipe size effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of gas lines with: 48l.f. of 1-1/2 p.e. gas line buried to a 400k btu using approved gas pipe per current plumbing code regulations note: carbon monoxi... see more
Valuation:
$500
Permit #:
RVSN-102503607-01
Status:
approved
Fee:
$75
Permit Type:
Revision to appro...
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: 100 of 2 pe gas line from meter to 400k btu pool heater and 40 of 1.25 pe to 75k btu fire pit. gas lines burried at 18 with 18 ga tracer wire using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are required ... see more
Valuation:
$500
Permit #:
CTR-102502340
Status:
final
Fee:
$195
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: 36 lf of 1.5 pe gas line from meter to 400k btu pool heater and 19 lf of 3/4 pe pipe to 65k btu bbq burried 18 below grade with 18 ga tracer wire using approved gas pipe per current plumbing code regulations note: carbon monoxide alarms are requi... see more
Valuation:
$500
Permit #:
CTR-102504106
Status:
final
Fee:
$168
Permit Type:
Repairs replacements
Building Type:
Single family
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: installation of 125 lf of 2 pe pipe & 10 lf of 3/4 pe pipe for a combined total of 134 lf from the gas meter to 65k btu bbq and 250k btu pool heater using approved gas pipe per current plumbing code regulations reviewer: sosor *******************... see more
Valuation:
$500
Permit #:
CTR-102500133
Status:
final
Fee:
$195
Permit Type:
Repairs replacements
Building Type:
Single family
Kerns plumbing LLC Reviews
BuildZoom hasn't received any reviews for Kerns plumbing LLC. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Verified License
BuildZoom confirmed this contractor's license
Kerns plumbing LLC License info
Verified License
| License # | 212887 |
| Status | Active |
| State | Arizona |
| Type | Specialty Dual |
| Business Type | Llc |
- BuildZoom verified this license was active as of February 2026.
Verify this license's status for Kerns plumbing LLC at the Arizona Registrar of Contractors.
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are Kerns plumbing LLC, log in and update your license info in the “Edit Profile” tab.
12.8K
Permits
- Building permit records show that Kerns plumbing LLC has worked on 12800 permitted projects.