Updated: Mar 12, 2026
Location and Projects
Address
4091 WILDWOOD DR NW, Williams, MN, 56686
Use our bidding system to
request a quote
Lake of the Woods Electric LLC
Lake of the Woods Electric LLC, 4091 Wildwood Dr NW, Williams, MN holds a Electrical license according to the Minnesota license board.
Their BuildZoom score of 96 ranks in the top 20% of 77,973 Minnesota licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Lake of the Woods Electric LLC, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Lake of the Woods Electric LLC Contact Information
Phone Number: (218) 783-7476
Edit
Address: 4091 WILDWOOD DR NW, Williams, MN 56686
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Building Permits by Lake of the Woods Electric LLC
This is a sample of this contractor's permits. Click here to access their complete permit history.
There is an existing electric off peak boiler that is going away. a propane boiler will be installed in replacement. there is an existing branch circuit for the riipple reciever that will be reused for the gas boiler and control circuit
Valuation:
N/A
Permit #:
ELE2411-07199
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Service call for power surges flickering lights and loud noise. found the existing feeder for the outdoor panel on the hill behind cabin 8 was shorted under the blacktop. trench a new feeder from the 200 amp exterior panel south side of cabin 7. spliced into the existing #2 urd with a 40 foot piece and landed on a 60 amp breaker
Valuation:
N/A
Permit #:
ELE2507-01075
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Install electrical panel and receptacles on the north exterior wall of cabin 11. install 1 90 amp feeder from the existing panel in the garage to the north exterior wall. install a 12 space panel surge protection and 3 branch circuits for outdoor receptacles
Valuation:
N/A
Permit #:
ELE2506-05581
Status:
final
Fee:
$60
Permit Type:
Non-dwelling
Building Type:
N/A
The existing 200 amp panel is damaged due to excessive heat. install a 200 amp disconnect on the outside of the house install a new 200 amp panel in the basement. reconnect the existing circuits
Valuation:
N/A
Permit #:
ELE2502-05902
Status:
final
Fee:
$92
Permit Type:
One-family dwelling
Building Type:
N/A
Install a new 20 amp 120 volt circuit for the cooler on the buffet line. install a 30 amp 120 volt circuit for the warming table on the buffet line. install a 20 amp 120 volt circuit for 3 new tv's
Valuation:
N/A
Permit #:
ELE2501-06033
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Carpenters install new bedroom window and damage the exiting receptacle circuit for the exterior wall. addition 2 boxes and extend the circuit to restore power. install code compliant circuit protection at the electrical panel
Valuation:
N/A
Permit #:
ELE2506-02824
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Install 6 120 volt 20 amp dedicated branch circuits for rapid charges for fishing boats. install a branch circuit for a future ceiling hung gas heater
Valuation:
N/A
Permit #:
ELE2505-04720
Status:
final
Fee:
$43
Permit Type:
One-family dwelling
Building Type:
N/A
The existing resort wells are running dry. a new well was drilled this fall on the far west side of the property. the resort has set a temporary wood framed insulated structure over the well casing to house the pressure tank and manifolds for distribution. install a new 100 amp service on a pedestal adjacent to the temporary well house. install branch circuits for the well electric he... see more
Valuation:
N/A
Permit #:
ELE2411-06097
Status:
final
Fee:
$60
Permit Type:
Non-dwelling
Building Type:
N/A
The existing branch circuit for the septic tank has failed. there is a 60 amp feeder 10 feet away that is feeder a rv pedestal. remove the old rv pedestal install a feeder panel. trench to the septic tank install 2 branch circuits for the septic alarm and pump
Valuation:
N/A
Permit #:
ELE2411-05988
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
The new ag lift station is located 3/4 of a mile south of 2934 62nd ave nw. it is located half of a mile south of the intersection of 62nd ave nw and 28 st nw. 100 amp electrical service 2 40 amp branch circuits for 2 lift pump controllers and a 20 amp circuit of a general purpose receptacle
Valuation:
N/A
Permit #:
ELE2411-02708
Status:
final
Fee:
$54
Permit Type:
Non-dwelling
Building Type:
N/A
The new ag lift station is located 1/3 of a mile straight south of 2934 62nd ave nw. it is located on. the corner of 62nd ave nw and 28th st. 100 amp electrical service 70 amp branch circuit for the lift station pump controller and a 20 amp circuit for a general purpose receptacle
Valuation:
N/A
Permit #:
ELE2411-02703
Status:
final
Fee:
$48
Permit Type:
Non-dwelling
Building Type:
N/A
New 50 amp feeder for a range. new 20 amp circuit for the microwave. new branch circuit for the garage sink area. extend the existing garage circuit for the new garage door opener. install a new receptacle using the existing branch circuit off the east side of the 3 season porch
Valuation:
N/A
Permit #:
ELE2408-05467
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
The walk in cooler and freezer condensers are overheating. they are currently installed in the back storage room. the existing wiring has the walk in cooler condenser lights and controls on a single circuit. i will seperate these loads and reuse the existing circuit to power the lights and controls. install a 3 new branch circuits. a 2 pole 20 amp for the walk in cooler condenser a 2 ... see more
Valuation:
N/A
Permit #:
ELE2408-04891
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
New circuit 15 a 120 volt circuit for a gas dryer #5. the dryers are hardwired with a local disconnect. clean up the existing wires for dryers 1-4. the existing wiring is exposed wires with wire nuts. replace the wire from the local disconnect to the dryer and replace with mc cable
Valuation:
N/A
Permit #:
ELE2406-07111
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
The service disconnects mounted on the pole in back have been bypassed and the breakers removed. this means there is no way to shut down the building without calling the city to pull the meter. replace the existing pole mounted service equipment with a new meter socket combination that provides a 200 amp and 100 amp main disconnects for the feeder panels. replace the damaged 200 amp e... see more
Valuation:
N/A
Permit #:
ELE2406-05350
Status:
final
Fee:
$92
Permit Type:
Non-dwelling
Building Type:
N/A
Install a 100 amp feeder between the old off peak electric panel to the existing 100 amp panel to restore power to the house. the utility company was contacted and verified that this old off peek panel has been removed from the off peak rate converted to straight rate many years ago
Valuation:
N/A
Permit #:
ELE2406-11134
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
A new garage is being built where the existing meter socket pedestal is located. the 200 amp meter socket is being moved by the utility. to a pole along the road. trench from the new meter socket location to the new garage. use the existing 100 amp feeder for the trailer and terminate in the new 200 amp service. install branch circuits for the new garage
Valuation:
N/A
Permit #:
ELE2405-10708
Status:
final
Fee:
$101
Permit Type:
One-family dwelling
Building Type:
N/A
A small addition was done and the washer/dryer stackable was added. the existing well and water heater branch circuit were cut by the remodeler. i extended the existing branch circuits to the new locations and installed lockable disconnects at the equipment. retro fit 4 garage 4 2 lamp strip lights to led
Valuation:
N/A
Permit #:
ELE2405-03778
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Sportsman's resort is moving the 200 amp feeder for the old shop to a new meter located on the same pole. this 200 amp feeder is currently on a meter that is feeding the ice fishing sleeper house business and they are separating the loads so they will have independent billing. the electric utility company has set a new 200 amp meter socket/disconnect combination on the same pole. hand... see more
Valuation:
N/A
Permit #:
ELE2404-03131
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Branch circuits for walk in freezer. replace the old power and controls for the existing walk in freezer. use the existing electrical panel to provide power for the new equipment and control. 1 circuit for the compressor 1 for the evaporator and controls 1 circuit for the lights heat tape and door heater and 1 for a general purpose outdoor receptacle
Valuation:
N/A
Permit #:
ELE2403-02242
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Similar Contractors See more
License # AM007597
Roseau, MN
106
BZ Score
-
Avg Project
-
Projects
License # EA777519
Baudette, MN
108
BZ Score
-
Avg Project
-
Projects
License # EA772914
Roseau, MN
106
BZ Score
-
Avg Project
-
Projects
Lake of the Woods Electric LLC Reviews
BuildZoom hasn't received any reviews for Lake of the Woods Electric LLC. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Hiring a contractor?
Verified License
BuildZoom confirmed this contractor's license
Lake of the Woods Electric LLC License info
Verified License
| License # | EA772240 |
| Status | Active |
| State | Minnesota |
| Type | Electrical |
- BuildZoom verified this license was active as of March 2026.
Verify this license's status for Lake of the Woods Electric LLC at the Minnesota Department of Labor & Industry.
This is a sample of licensing data; click here to access a complete history.
96
BuildZoom Score
192
Permits
- Building permit records show that Lake of the Woods Electric LLC has worked on 192 permitted projects.