Updated: Jun 10, 2026
Location and Projects
Address
7623 ST CROIX TR LN S, Hastings, MN, 55033
Use our bidding system to
request a quote
M and T Electric Inc
M and T Electric Inc, 7623 St Croix Tr Ln S, Hastings, MN (Employees: David J. Chapeau and Timothy Chapeau) holds a Electrical license and 3 other licenses according to the Minnesota license board.
Their BuildZoom score of 108 ranks in the top 5% of 77,973 Minnesota licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring M and T Electric Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
M and T Electric Inc Contact Information
Phone Number: (651) 967-0280
Edit
Address: 7623 ST CROIX TR LN S, Hastings, MN 55033
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
M and T Electric Inc Hastings
Quality
108
95th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
M and T Electric Inc has a BuildZoom score of 108, which places them above 95% of 77,973 contractors in Minnesota.
Activity
|
27 projects
|
2025 |
|
12 projects
|
2024 |
|
45 projects
|
2023 |
Our building permit records indicate that M and T Electric Inc has worked on at least
84.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
16 projects
|
New Constructions |
|
81 projects
|
Electrical projects |
Analyzing permits over the last 4 years shows that M and T Electric Inc mostly works on
electrical project
and new construction
projects.
Pricing
|
20 projects
|
< $5k |
|
3 projects
|
$5k-$20k |
|
1 project
|
$100k-$250k |
The typical size of their permits is approximately $1,893. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
We will remove and replace the 8(eight) receptacles near the sinks in the following rooms. the first examination room has 1 receptacle the second examination room has 1 receptacle the treatment area has 2 receptacles the surgery room has 1 receptacle the lab/pharmacy area has 2 receptacles. one is a gfci and one is not the guest bathroom has 1 receptacle. while looking at the images o... see more
Valuation:
N/A
Permit #:
ELE2503-01914
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Scope for installing new service: - the new service will be a 3-phase 480v 600a system with a mechanical transfer switch - installation will include 2 fused disconnects 1 for the north flare and 1 for refeeding the pump house - all work will be carried out in compliance with local electrical codes and regulations - the installation will be performed by qualified and certified electric... see more
Valuation:
N/A
Permit #:
ELE2408-12260
Status:
final
Fee:
$88
Permit Type:
Non-dwelling
Building Type:
N/A
Remove and leave the existing distribution panel and circuit breakers on site. the wires between the meter socket and distribution panel will be upgraded to 200-amp wire. the new meter socket distribution panel wiring and circuit breakers will be installed and the wiring will be terminated
Valuation:
N/A
Permit #:
ELE2506-03186
Status:
final
Fee:
$87
Permit Type:
One-family dwelling
Building Type:
N/A
Concrete work is being done at university flats and there are two pedestal lights that need the determination of wiring so that it is safe for the crew working in the area
Valuation:
N/A
Permit #:
ELE2410-07696
Status:
final
Fee:
$36
Permit Type:
Multi-family dwel...
Building Type:
N/A
We will mount two (2) wall-mount junction boxes at each of the nine (9) door locations per allied solutions mounting instructions we will run a 1/2 emt conduit from the vehicle restraint control box up the wall to the wall-mounted j-box on the same side of the door as the vehicle restraint control box. we will connect the two (2) wall-mounted j-boxes with 1/2 emt conduit once the cond... see more
Valuation:
N/A
Permit #:
ELE2311-03784
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Change all the upstream receptacles to gfci in the garage.the switch for the heater cant to on the load side of a gfci and use mc to the heater
Valuation:
N/A
Permit #:
ELE2501-00676
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Install #2 aluminum mc cable from the panel to a junction box that will be wall-mounted in the area of the two ev chargers. from the junction box to the charger we will run #6 awg copper. conduits running from the junction box to the charger will be 3/4 emt. breakers will be 60a and dedicated circuits. total wire length will be under 160
Valuation:
N/A
Permit #:
ELE2311-02283
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
We will install the generator interlock kit on the service panel dead front install the 50 amp circuit breaker in the panel and run #6 awg copper wire from the breaker panel to the exterior wall in the area where the electrical service enters the house where the inlet box will be mounted. the generator you intend to use has a bonded neutral. we will need to un-bond the neutral wire on... see more
Valuation:
N/A
Permit #:
ELE2310-09823
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Tap the existing 70 amp ev feeder and extend it to the new evse mounted near spaces 2 and 3. we will match the existing feed wire size. code requires at least a 4 gauge copper on a 70 amp breaker. this will be installed in a 1-inch conduit and the run is aproxamently 70 feet in length we are not adding any additional loads to the existing feeder/infrastructure due to the power-sharing... see more
Valuation:
N/A
Permit #:
ELE2302-06764
Status:
final
Fee:
$36
Permit Type:
Multi-family dwel...
Building Type:
N/A
Expose underground service laterals install handhole and connect to the transformer addition new wire
Valuation:
$12,000
Permit #:
MI292611
Status:
final
Fee:
$362
Permit Type:
Commercial/ind
Building Type:
N/A
Replace the house panel and its breakers change the incoming lugs to match the conductors clean the remaining gear change the backboard to non-combustible and close open knockouts
Valuation:
N/A
Permit #:
ELE2411-02281
Status:
final
Fee:
$60
Permit Type:
Multi-family dwel...
Building Type:
N/A
2 wall-mounted chargers: install #6 awg copper to each wall-mounted charger. the longest wire run will be 45 with the second run being 35. the conduit will be 1 emt. breakers are to be 60a each and a dedicated circuit
Valuation:
$11,000
Permit #:
R23-1807CE
Status:
complete
Fee:
$141
Permit Type:
N/A
Building Type:
N/A
Provide and install an evercharge ev charger in stall g3 in the parking garage
Valuation:
N/A
Permit #:
ELE2409-03442
Status:
final
Fee:
$36
Permit Type:
Multi-family dwel...
Building Type:
N/A
Trench new underground service laterals from transformer to meter socket
Valuation:
$12,000
Permit #:
MI292612
Status:
final
Fee:
$362
Permit Type:
Commercial/ind
Building Type:
N/A
Install 1 50 amp ev charging receptacle wall plate and circuit breaker
Valuation:
N/A
Permit #:
ELE2503-04121
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Single circuit reconnect for a fire control panel replacement
Valuation:
$1,000
Permit #:
MG405487
Status:
final
Fee:
$76
Permit Type:
Alarm communication
Building Type:
N/A
Fire control panel: replacing the power portion of this only
Valuation:
N/A
Permit #:
ELE2504-05855
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Trench from the house to the outbuilding with new conduit and wire sized for a 100a sub panel and current loads. we will coordinate the crossing of other utilities and locates. we will provide the electrical permit and coordinate inspections. we will install a new qo panel with 20 spaces in the barn. we will also extend the existing circuits to the new panel and terminate
Valuation:
N/A
Permit #:
ELE2103-10463
Status:
final
Fee:
$60
Permit Type:
One-family dwelling
Building Type:
N/A
-receptacle replacement per each: this line is a per-unit replacement cost from an ungrounded 3 prong or 2 prongs receptacle to a dual function receptacle. we had talked about 3 in the upstairs bedroom 3 in the basement 3 in the kitchen serving the countertop one in the bathroom one in the living room in the tv location. for a total of 11. -ac breaker: change the breaker for the air c... see more
Valuation:
N/A
Permit #:
ELE2105-08389
Status:
final
Fee:
$172
Permit Type:
One-family dwelling
Building Type:
N/A
Install power from the panel located in the garage to the new mini-split system. emt conduit shall run just under the siding on the wall to the corner of the garage where the mini-split will be located. a service disconnect with a gfci receptacle will be supplied adjacent to the mini-split. all low voltage wiring thermostats and connections between the indoor and outdoor unit are by o... see more
Valuation:
N/A
Permit #:
ELE2106-10007
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Similar Contractors See more
128
BZ Score
$600
Avg Project
-
Projects
156
BZ Score
$5K
Avg Project
-
Projects
133
BZ Score
$9.3K
Avg Project
-
Projects
M and T Electric Inc Reviews
BuildZoom hasn't received any reviews for M and T Electric Inc. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Verified License
BuildZoom confirmed this contractor's license
M and T Electric Inc License info
Verified License
| License # | EA005071 |
| Status | Active |
| State | Minnesota |
| Type | Electrical |
| Business Type | Corporation |
- BuildZoom verified this license was active as of March 2026.
Verify this license's status for M and T Electric Inc at the Minnesota Department of Labor & Industry.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | BV001778 |
| Status | Active |
| City | Burnsville |
| Type | Contractor, Electrical |
| Business Type | Corporation |
- When BuildZoom last verified this license, it had an expiration date of February, 2016. Check the current license status of M and T Electric Inc with the The City of Burnsville, MN
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | 1271165 |
| Status | Inactive |
| City | Milwaukee |
| Type | Electrical |
| Business Type | Corporation |
- According to the City of Milwaukee License Search, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for M and T Electric Inc at the City of Milwaukee License Search.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | CA05071 |
| Status | Inactive |
| State | Minnesota |
| Type | Class A Electrical Contractor |
| Business Type | Corporation |
- According to the Minnesota Department of Labor & Industry, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for M and T Electric Inc at the Minnesota Department of Labor & Industry.
This is a sample of licensing data; click here to access a complete history.
108
BuildZoom Score
315
Permits
- Building permit records show that M and T Electric Inc has worked on 315 permitted projects.
M and T Electric Inc Employees
DC
David J. Chapeau
TC
Timothy Chapeau