Bolter Construction Electrician

Bolter Construction, 132 Lapham Way, San Francisco, CA (Owned by: James Allen Bolter) holds a General Building, Electrical, Plumbing license according to the California license board.

Their BuildZoom score of 108 ranks in the top 5% of 336,931 California licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Bolter Construction, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Bolter Construction Contact Information

Phone: (415) 377-0374
Address: 132 Lapham Way, San Francisco, CA 94112

Bolter Construction San Francisco

Quality

108
95th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Bolter Construction has a BuildZoom score of 108, which places them above 95% of 336,931 contractors in California.

Activity

1 project
2026
7 projects
2025
13 projects
2024
5 projects
2023
Our building permit records indicate that Bolter Construction has worked on at least 26.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

13 projects
Electrical projects
Analyzing permits over the last 4 years shows that Bolter Construction mostly works on electrical project projects.

Pricing

1 project
< $5k
2 projects
$5k-$20k
2 projects
$50k-$100k
Value Not Public: 20.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Bolter Construction

Sort by: Notable Notable | Date Date | Job Value Job Value
Finish the electrical work started in the common area (as per expired permit #e20190418690). rewire as per code the new residential space; one ex. bathroom one new kitchen one new bathroom one ex. office space and the converted lining area. install mini-split-air heat power. as per permit #202502039548
Valuation:
N/A
Permit #:
EW202502184232
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Work category: 3pa; complete work started under permit #pw20210823109. install new laundry (3 clothes washers and 3 gas dryers) and new bathroom (sink toilet and shower) in converted from commercial to residential space.(underground 9-02-2021) as per permit #202502039548
Valuation:
N/A
Permit #:
PW20250218163
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Work category: 3pa; remodel ex. bathroom (remove ex. shwr. install new sink and toilet fixtures) install one new kitchen (sink) one new bathroom (sink toilet shower stall and tub) and one new water heater with a new gas line from its’ gas meter. install mini-split-air heat unit. as per permit #202502039548
Valuation:
N/A
Permit #:
PW20250218162
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install electrical for new laundry area (three clothes washers & three gas dryers) and new bathroom (gfci recpt. & fan) 8 receptacles and 9 led lights and 6 switches as per code. per permit #202502039548
Valuation:
N/A
Permit #:
EW202502184234
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Apt#6 install a new sub-panel in an approved location to replace the fused panel (to be used as a junction box) in its unapproved closet location. replace the existing 40amp/220v 20amp/110v and the 15amp/110v fuses with a 40amp/220 breaker a 20/110vamp arc-fault breaker & a15amp/110v arc-fault breaker in the new sub-panel
Valuation:
N/A
Permit #:
EW202407220016
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Apt#5 install a new sub-panel in an approved location to replace the fused panel (to be used as a junction box) in its unapproved closet location. replace the existing 40amp/220v 20amp/110v and the 15amp/110v fuses with a 40amp/220 breaker a 20/110vamp arc-fault breaker & a15amp/110v arc-fault breaker in the new sub-panel
Valuation:
N/A
Permit #:
EW202407220015
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Apt#4 install a new sub-panel in an approved location to replace the fused panel (to be used as a junction box) in its unapproved closet location. replace the existing 40amp/220v 20amp/110v and the 15amp/110v fuses with a 40amp/220 breaker a 20/110vamp arc-fault breaker & a15amp/110v arc-fault breaker in the new sub-panel
Valuation:
N/A
Permit #:
EW202407220013
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Apt#3 install a new sub-panel in an approved location to replace the fused panel (to be used as a junction box) in its unapproved closet location. replace the existing 40amp/220v 20amp/110v and the 15amp/110v fuses with a 40amp/220 breaker a 20/110vamp arc-fault breaker & a15amp/110v arc-fault breaker in the new sub-panel
Valuation:
N/A
Permit #:
EW202407220012
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Apt#2 install a new sub-panel in an approved location to replace the fused panel (to be used as a junction box) in its unapproved closet location. replace the existing 40amp/220v 20amp/110v and the 15amp/110v fuses with a 40amp/220 breaker a 20/110vamp arc-fault breaker & a15amp/110v arc-fault breaker in the new sub-panel
Valuation:
N/A
Permit #:
EW202407220011
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Apt#1 install a new sub-panel in an approved location to replace the fused panel (to be used as a junction box) in its unapproved closet location. replace the existing 40amp/220v 20amp/110v and the 15amp/110v fuses with a 40amp/220 breaker a 20/110vamp arc-fault breaker & a15amp/110v arc-fault breaker in the new sub-panel
Valuation:
N/A
Permit #:
EW202407220010
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Work category: 1p; remodel existing upper bathroom half bathroom & kitchen on ground floor install new bath(shwr sink & toilet) new bar sink laundry area(washer drain and sink) and new water heater as per expired permit pw20221020893. final inspection needed
Valuation:
N/A
Permit #:
PW20240507616
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove the unsafe100amp/220v federal pacific main panel leave existing meter. install a new 100amp/220v siemens main panel with a 100amp main breaker new circuit breakers and new arc-fault breakers as needed for the existing panel circuits
Valuation:
N/A
Permit #:
EW202407059723
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Work category: 1p; install a new 120 k btu forced air 80% furnace in the same location where the old 120k btu was located and had been removed. install approx. 30’ of new insulated ducting that had been removed for the furnace change-out
Valuation:
N/A
Permit #:
PW20241107976
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Work category: 1p; replace existing gas gravity furnace with a new heat pump and addition a minisplit heat pump in the inlaw garage bedroom and living area. complete work done under expired permit #pmw20230604503
Valuation:
N/A
Permit #:
PW20240906393
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Kitchen & bathroom rmeodel. no layout changes to kitchen: new countertop backsplash and cibnet faces. 1 bathroom change tub shower to walkin shower. new tile in entire bathroom. addition overhead lighting & new vanity and fan. non-structural work
Valuation:
$50,000
Permit #:
202107124207
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
24 - apartments
Remove the existing 200amp/220v main disconnect and it's 5 apartment meters and house meter. replace with a 400amp/220v main disconnect with 6 apartment meters and 1test bypass house meter. install 6ea.100amp/220v apartment sub-panels and 1ea. 70amp/220v house sub-panel
Valuation:
N/A
Permit #:
EW202309254022
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace 2 allumionium windows on first level of 18th st side and w wood clad double hung glaze windows - replace two single glaze windows on parking pad wall not seen from street. with dual glaze vinyl windows tempered glass.total of 4 windows in same locations
Valuation:
$5,500
Permit #:
202206247079
Status:
expired
Fee:
N/A
Permit Type:
N/A
Building Type:
24 - apartments
4355 18th aka 109 eureka st: replace electric heaters.rev to pa# 202103045788. install a 24k tub oval zone mini split air flat heat system in 600 sq ft cover one bedroom apartment install a 12k btu mini split air/heat system in commercial 300 sq ft uint
Valuation:
$7,000
Permit #:
202112305191
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
24 - apartments
Work category: 1p; remove and replace the existing damaged shower valve. with a sfca. approved model
Valuation:
N/A
Permit #:
PW20250423766
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Work category: 1p; remove the existing old 100k btu gravity furnace and replace with a new 100k btu forced air 80% furnace. replace approx. 35’ of existing ducting for furnace change out
Valuation:
N/A
Permit #:
PW20241120279
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Bolter Construction Reviews

BuildZoom hasn't received any reviews for Bolter Construction. Click here to be alerted when reviews are posted about them.
Please write a review about Bolter Construction
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.