Share your project details and we'll reach out to
Metropolitan Fire Protection Co Inc
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Their BuildZoom score of 112 ranks in the top 3% of 125,106 Pennsylvania licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Metropolitan Fire Protection Co Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Metropolitan Fire Protection Co Inc Contact Information
For the erection of an atached structure for use as single-family household living. sheeting and shoring as prescribed in geotech report. (underpinning not a part of this permit). separate permits required for sprinkler (nfpa 13r) work. energy code compliance in accordance with 2018 iecc. prior to issuance of c/o submittal of air barrier checklist and envelope testing certificate is r... see more
Level ii alterations with partial change of occupancy to create a religious assembly use in suite 203 of an existing building as per approved plans. existing building sprinklered. *2018 iebc review* **separate permits required for mep & fire suppression work**
For the erection of a vertical addition on an existing attached structure with level iii alteration to create a vacant commercial space on the 1st floor with two-family household living above. only the residential portion to be sprinklered per nfpa 13r. separate permits required for mep & fp work. amendment#1 to addition mechanical closets to 2nd and 3rd floors within dwelling units. ... see more
For level ii alterations to include structural work ada lift new partitions fixtures doors furnishings finishes as per approved plans. separate permits required for mep and fire supression work. *2018 iebc* *separate use permit required for vacant commercial spaces prior to occupancy.*
For the installation of a new fire pump and extention of an existing fire suppression system per approved plans hydraulic calculations nfpa 13 and nfpa 20
Erection of an attached structure for use as single-family household living. sheeting and shoring as prescribed in geo tech report. separate permits required for electrical mechanical plumbing and sprinkler (13d) work. underpinning is part of this permit with continued inspections. energy code compliance in accordance with 2018 iecc. prior to issuance of c.o submittal of air barrier c... see more
Erection of an attached structure for use as single-family household living. sheeting and shoring as prescribed in geo tech report. separate permits required for electrical mechanical plumbing and sprinkler (13d) work. (no underpinning on this permit). energy code compliance in accordance with 2018 iecc. prior to issuance of c.o submittal of air barrier checklist and envelope testing ... see more
To install new fire suppression system complying with nfpa 13 throughout the basement and 1st floor to include four (4) inch main fire service line with a 4 ames colt 200 backflow prevention assembly and for the installation of a nfpa 13r automatic fire suppression system for the 2nd and 3rd floor. all work shall be done in accordance with approved plans hydraulic calculations
Install new fire suppression system complying with nfpa 13r throughout the building to include 2 main fire service line with a 2 wilkins 950xlt2bfss backflow prevention assembly as per approved plans. all work shall be performed by a fire suppression contractor licensed by the city of philadelphia
For the installation of a fire suppression system in accordance with nfpa 13r throughout the entire building with 1.5” fire service and 2 backflow prevention assembly. all work shall comply with the approved plans. all work shall be performed by a fire suppression contractor licensed by the city of philadelphia
For level ii alterations to include wet floodproofing (flood openings) new partitions fixtures furnishings finishes millwork as per approved plans. separate permits required for mep and fire suppression work. *2018 iebc*
Install new fire suppression system complying with nfpa 13r throughout an existing structure. installation to include 2"fire service line and 2 dc wilkins 950 xlt2 backflow prevention assembly as per approved plans. all work shall be performed by a fire suppression contractor licensed by the city of philadelphia
For the installation of an automatic fire suppression system in accordance with nfpa 13d throughout three story building to include 1-inch combined water service line as per approved plans. all work shall be done in accordance with approved plans/hydraulic calculations. if field conditions vary contact design engineer prior to the start of any work
For the installation of an automatic wet sprinkler system throughout a three (3) story single-family dwelling to include a one (1) inch combined domestic & fire service line. all work to be done per approved plans and in accordance with nfpa 13d by a fire suppression contractor licensed by the city of philadelphia. see rp-2024-006864 for associated building permit
For the installation of an automatic wet sprinkler system throughout a three (3) story single-family dwelling to include a one (1) inch combined domestic & fire service line. all work to be done per approved plans and in accordance with nfpa 13d by a fire suppression contractor licensed by the city of philadelphia. see rp-2024-006779 for associated building permit
Install new fire suppression system complying with nfpa 13r throughout the building to include 2 main fire service line with a 2 wilkins 950xlt2bfss backflow prevention assembly as per approved plans. all work shall be performed by a fire suppression contractor licensed by the city of philadelphia
For the installation of an automatic wet sprinkler system throughout the residential occupancy at the 2nd and 3rd floors to include a two (2) inch fire service line and a two (2) inch backflow preventer. 1st floor commercial space to remain non-sprinklered. all work to be done per approved plans and in accordance with nfpa 13r by a fire suppression contractor licensed by the city of p... see more
Ez permit sprinkler relocation (nfpa 13)- for the relocation of sprinkler heads as per attached standards. deviations from these standards require submission of construction and site plans. relocate 35 existing sprinkler heads on the automatic fire sprinkler system per nfpa 13
For the installation of an nfpa 13r system for a multi-family dwelling serviced by a two (2) inch fire service line with a 2-inch wilkins 950xlt2bfss backflow preventer and automatic fire suppression system. all work shall be done in accordance with approved plans/hydraulic calculations. if field conditions vary contact design engineer prior to the start of any work
For the installation of an nfpa 13r system for a multi-family dwelling serviced by a two (2) inch fire service line with a 2-inch wilkins 950xlt2bfss backflow preventer and automatic fire suppression system. all work shall be done in accordance with approved plans/hydraulic calculations. if field conditions vary contact design engineer prior to the start of any work
BuildZoom verified this license was active as of July 2026.
Verify this license's status for Metropolitan Fire Protection Co Inc at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
Verified License
HIC #
21104
Status
Active
City
Philadelphia
Type
Fire Suppression Contractor
BuildZoom verified this license was active as of July 2026.
Verify this license's status for Metropolitan Fire Protection Co Inc at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
Verified License
HIC #
36316
Status
Active
City
Philadelphia
Type
Fire Suppression Worker
BuildZoom verified this license was active as of July 2026.
Verify this license's status for Metropolitan Fire Protection Co Inc at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
HIC #
PA021892
Status
Active
State
Pennsylvania
When BuildZoom last verified this license, it had an expiration date of July, 2025. Check the current license status of Metropolitan Fire Protection Co Inc with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.