Oil to gas conversion. new gas furnace and replace existing split air conditioning system. new steel gas mains from meter to appliance. new heil furnace model # g96vtn1002120 rated at 100 000 btu's and new heil air conditioning unit model # h4a7t48 rated at 48 000 btu's. system will have pvc flue and chimney will no longer be used. oil tank removal by other (tank works)
New construction home. new 2 zone gas fired warm air heating system with split air conditioning. gas piping by others. heil model g96vtn0601716 60, 000 btu 2 stage furnace with a heil h4as36 3 ton condesning unit 36, 000 btu's. system will include a air cycler fresh air control to meet ashrae 62.2
Remove existing carrier 40, 000btu(in) 92% afue direct vent natural gas furnace with plugged secondary heat exchanger and install the following heil furnace in its place: (1) md# g96vtn0401410a1 40, 000btu (in) 38, 400btu (out) 96% afue two stage natural gas direct vent condensing furnace with an ecm variable speed blower assembly
Installing a new mitsubishi h2i hyper heat mini-split heat pump system to provide air conditioning and heating to the 1st 2nd and 3rd floors of a single family residential home using the following equipment: (1)md# svz-kp30na 13 400-27, 000btu (cooling) 13, 000-34, 000btu (heating) multi-position air handler located in attic area above 3rd floor (1)md# msz-fs09na-u1 9, 000btu wall eva... see more
Replacement of plastic refrigeration linesets above bonus room over garage. new copper linesets to be installed on a perfect aire 2:1 ductless heat pump. emergency pan switches to be added to each indoor wall evaporator. existing outdoor heat pump perfect aire m# 3pams18 18, 000 btu's
Emergency gas boiler replacement. resident has no heat. existing 90+ % high efficiency gas boiler replacement with a new utica mahf-165 95% condensing gas boiler heat only. rated at 165 000 btu input and net 153 000 btu's modulating boiler
Replace and relocate (3) gas boilers from under sidewalk and into basement. boilers to be changed from 80% chimney vent to high efficiency condensing gas and flue pipe to be routed out south side of building through old duct chase. 40 gallon gas water heater to be eliminated and replaced with 40 gallon high efficiency electric water heater. new fire rated boiler room mechanical room t... see more
Ducted mini-split replacement. existing lg system to be removed and replaced with a new mitsubishi suz-ka36 heat pump and mitsubishi svz-kp36 air handler rated at 36 000 btu's
Install a complete new mitsubishi mini split heat pump system to condition various rooms and areas in a ranch style home using the following equipment: (1) md# msz-fs12na 12, 000btu wall evaporator which will be located on the upper wall of the rear family room (1) md# svz-kp24na 24, 000btu 2.0 ton air handler which will be located in the attic area above the 1st floor of the home (1)... see more
Install a new mitsubishi ductless heat pump system to condition various areas inside the home using the following equipment: (1) md# msz-fs12na-u1 12, 000btu 1.0 ton wall mounted indoor evaporator with factory supplied remote controller which will be located in one of the bed rooms (1) md# msz-fs18na-u1 18, 000btu 1.5 ton wall mounted indoor evaporator with factory supplied remote con... see more
Install new hvac system and associated duct work for a single family two story home. 95% gas furnace located in basement with pvc flue pipe out the side of home. gas piping and wiring by others. heil model #n95esn0601714 rated at 60 000 btu input
Remove (1) weil mclain oil fired boiler with tankless coil and (1) 30 gallon buffer hot water storage tank from home and install the following utica high efficiency gas fired combi boiler in their place: (1) md# macf-150 125, 000-153, 000btu (in) 113, 000-136, 000btu (doe out) 98, 000btu (net ibr) 95% afue natural gas modulating floor mounted boiler. we will complete all new gas pipin... see more
Roughing a one full bathroom laundry and kitchen with pvc piping and pex. then on the finish i will be installing the fixtures that the customer is providing
Replacement of (2) existing water to air geothermal heat pumps. new units water furnace model # w5av024bd rated at 30 000 btu's with 10kw back up electric heat
Installation of a mitsubishi ductless mini split heat pump to supplement heating and cooling in a bonus room over the garage. mitsubishi model #muzfs12 12, 000 btu's
Installation of a new propane fired hvac split system. two zones. pvc flue pipe. gas piping by others. heil two stage gas furnace g9vtn060 60, 000 btu's and a heil air conditioning condenser hsa636 36, 000 btu's