×

Don't wait to get an HVAC Pro

We make finding an HVAC/mechanical contractor fast, easy, and commitment-free.

Call now (623) 404-9188
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >
N

Location and Projects

Address
ENERGY TODAY 6143 CLARK CENTER AVE SARASOTA, FL 34238, Sarasota, FL, 34238
Use our bidding system to request a quote

N and M Heating and Cooling Serv

N and M Heating and Cooling Serv, Energy Today Ave, Sarasota, FL (Owned by: N&M Cooling And Heating Inc) holds a Contractor license and 14 other licenses according to the Clermont license board.

Their BuildZoom score of 111 ranks in the top 4% of 191,428 Florida licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring N and M Heating and Cooling Serv, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

N and M Heating and Cooling Serv Services

Start a project today:

N and M Heating and Cooling Serv Contact Information

Phone: (941) 256-9400 Edit
Address: ENERGY TODAY 6143 CLARK CENTER AVE SARASOTA, FL 34238, Sarasota, FL 34238 Edit

N and M Heating and Cooling Serv Sarasota

Quality

111
96th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
N and M Heating and Cooling Serv has a BuildZoom score of 111, which places them above 96% of 191,428 contractors in Florida.

Activity

580 projects
2025
595 projects
2024
523 projects
2023
Our building permit records indicate that N and M Heating and Cooling Serv has worked on at least 1698.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

8 projects
Home Additions
6 projects
New Constructions
4 projects
Commercial Renovations
1582 projects
HVAC projects
725 projects
Mechanical projects
Analyzing permits over the last 4 years shows that N and M Heating and Cooling Serv mostly works on hvac project and mechanical project projects.

Pricing

67 projects
< $5k
1011 projects
$5k-$20k
90 projects
$20k-$50k
5 projects
$50k-$100k
3 projects
$100k-$250k
Value Not Public: 502.0 projects
The typical size of their permits is approximately $10,437. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by N and M Heating and Cooling Serv

Sort by: Notable Notable | Date Date | Job Value Job Value
Alterations/repairs - commercial
2025-01-10
Air conditioning equal change out 20 ton 3 phase straight cool package unit on existing roof rack with new exterior metal duct work. this supplies the common hallways. also replacing exterior duct work for adjacent existing high pressure unit. rheem tonn: 20 k.w. : na seer: eer 95f pkg unit on roof on exist stand or curb change out
Valuation:
$86,775
Permit #:
2025-004116
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - commercial
2025-04-17
Air conditioning equal change outs. 5 ton straight cool split system 16.00 seer2 15 kw. ahu vert closet cond on existing roof stand. 3 ton straight cool split system 15.50 seer2 10 kw. ahu vert closet cond on existing roof stand
Valuation:
$22,503
Permit #:
2025-008661
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Air conditioning replacement
2025-03-22
Change out like for like split system hvac 16 seer 3.0 ton 8 k/w rev1- permit requested as 1 system replacement. job sold was for 2 hvac split systems. both systems were identical - 16.00 seer 3.o ton 8 k/w 8396 laurel lakes blvd naples
Valuation:
N/A
Permit #:
PRAR20240939134
Status:
inspections commenced
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
Residential one a...
Alterations/repairs - residential
2025-01-03
Hurricane helene air conditioning equal change outs 3 systems 3 ton 2.5 ton and 2 ton. all 14.30 seer2. all 5 kw. raising from on pads on ground to wall brackets 4 feet up. split systems in closet ***storm damage***
Valuation:
$27,820
Permit #:
2025-001713
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - commercial
2025-03-31
Air conditioning equal change out 2.5 ton straight cool split system ahu vert in closet cond on existing roof stand name brand: ruud tonnage: 2.5 k.w. 7 seer 15.20 split system - in closet - on roof on exist stand/curb
Valuation:
$9,535
Permit #:
2025-008085
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - residential
2025-07-24
Hurrican damage. air conditioning equal change out 2 systems. 4 ton straight cool split system 14.80 seer2 7 kw. 2 ton straight cool split system 14.30 seer2 5 kw. both condensers moved from front of house to roof racks back of house. both ahu hor in attic. this is storm damage - helene rudd new rood stand
Valuation:
$22,219
Permit #:
2025-010300
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - residential
2025-10-10
***storm damage**ac equal change out 5 ton heat pump split system ahu horizontal in garage condenser from existing pad raised onto roof rack on pad using existing wiring. complete duct replacement. storm damage kw 7 seer 15.20 new roof stand change out
Valuation:
$19,869
Permit #:
2025-008343
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Change out split system hvac with heat pump mini split 21.80 seer 3.0 ton no heat in an occupied mobile/manufactured home. using existing electricity from split system that is being replaced. 11 enchanting blvd
Valuation:
N/A
Permit #:
PRHV20240727522
Status:
final
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
Residential one a...
Alterations/repairs - commercial
2025-04-02
This is st armands towers south. 10 ton 11.20 seer ruud 3 ph straight cool package unit on roof on new aluminum system stand fabricated by presley metal no heater supplies common areas
Valuation:
$54,017
Permit #:
2025-008392
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - commercial
2024-12-18
5 systems. #1 and #2 both 3 ton straight cool split systems 8 kw vert in closet on pad on ground. #3 2 ton straight cool split system 8 kw vert in closet on pad on ground. #4 4 ton straight cool split system 8 kw horizontal in attic pad on ground. #5 5 ton straight cool split system 8 kw horizontal in attic pad on ground
Valuation:
$36,836
Permit #:
2025-003232
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - commercial
2025-05-15
Air conditioning equal change out 3.5 ton 3 ph straight cool split system 15.20 seer2 7 kw cond on existing roof rack labelled unit 105 ahu hor in attic name brand: american standard tonnage: 3.5 k.w. 7 seer 15.20 split system - on roof on existing stand - change out
Valuation:
$14,262
Permit #:
2025-010221
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - residential
2025-08-21
Install two new minisplit ductless heat pumps-one 1.5 ton (18 000 btu) condenser with dual heads (one 9 000 btu for son's room & one 6 000 btu for bathroom) 21.00 seer2. one 3/4 ton (9 000 btu) condenser with one 9 000 btu head for master br 24.00 seer2. no kw on pad on ground
Valuation:
$12,534
Permit #:
2024-012785
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Plumbing permit
2025-02-26
Replace sewer from house to city replacing approximately 50 ft of 4” thin pvc wall pipe original construction with 4” schedule 40 pvc due to a break in line from roots also installing two-way clean out
Valuation:
$6,153
Permit #:
A25-001508
Status:
final
Fee:
$137
Permit Type:
N/A
Building Type:
N/A
Alterations/repairs - commercial
2025-09-29
Air conditioning equal change out condenser only 40 ton straight cool 3 ph 12.5 eer on existing stand on roof. asset #2181. please see page 8 of attached tech guide provided by manufacturer for eer rating. unit controls second floor
Valuation:
$44,853
Permit #:
2025-011732
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Air conditioning replacement
2025-07-02
Air conditioning equal change out 2 systems. #1 - 5 ton straight cool split system 13.80 seer2 no heat strip. condenser on existing roof stand ahu on existing hanging kit. #23 - 3 ton heat pump split system 14 seer 10 kw. condenser on existing roof stand ahu on existing hanging kit
Valuation:
N/A
Permit #:
PRAR20250728623
Status:
filed
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
N/A
Mechanical
2025-06-26
Air conditioning equal change out 2 systems. #1- 5 ton straight cool split system 13.80 seer2 no heat strip. condenser on existing roof stand ahu on existing hanging kit. #23 - 3 ton heat pump split system 14 seer 10 kw. cond on existing roof stand ahu on existing hanging kit
Valuation:
N/A
Permit #:
PRHV20250627792
Status:
filed
Fee:
N/A
Permit Type:
Alteration/remodel
Building Type:
N/A
Alterations/repairs - residential
2024-10-15
Air conditioning change out upsize from 3 ton heat pump split system to 3.5 ton heat pump split system. addition new 6 supply to living room and move existing 6 supply 3 feet to the rightn ruud 5kw seer 15.20 split system in closet on pad on ground chnage out
Valuation:
$12,109
Permit #:
2025-000324
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Residential mechanical
2025-05-21
Air conditioning changeout--replacing 2 ton straight cool split system & ductwork with a 28 000 btu 23.5 seer2 heat pump ductless mini-split with three heads (two 9 000 btu and one 18 000 btu)
Valuation:
$10,022
Permit #:
20250517958
Status:
issued
Fee:
$94
Permit Type:
N/A
Building Type:
N/A
Plumbing
2024-08-15
Hurricane ian repairs - revision #1 -install 100 amp 4 space circuit sub panel - revision #2 - replace existing front door with new front door of same dimensions fl #17247.13 + - 35.0 is design pressure. rev #3 remove the replacement of the front door. the original door on the house will not be removed or replaced
Valuation:
N/A
Permit #:
PRAD2207291-PL1
Status:
final
Fee:
N/A
Permit Type:
Alteration
Building Type:
N/A
Electrical
2024-08-15
Hurricane ian repairs - revision #1 -install 100 amp 4 space circuit sub panel - revision #2 - replace existing front door with new front door of same dimensions fl #17247.13 + - 35.0 is design pressure. rev #3 remove the replacement of the front door. the original door on the house will not be removed or replaced
Valuation:
N/A
Permit #:
PRAD2207291-EL2
Status:
final
Fee:
N/A
Permit Type:
Alteration
Building Type:
N/A

Similar Contractors See more

License #
125
BZ Score
$7K
Avg Project
-
Projects
License # 1740-01
125
BZ Score
$9K
Avg Project
-
Projects
License # EC13003840
125
BZ Score
$1.8K
Avg Project
-
Projects

N and M Heating and Cooling Serv Reviews

BuildZoom hasn't received any reviews for N and M Heating and Cooling Serv. Click here to be alerted when reviews are posted about them.
Please write a review about N and M Heating and Cooling Serv
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.