Updated: Dec 30, 2025
Location and Projects
Address
110 E 30th St, Manhattan, NY, 10016
Use our bidding system to
request a quote
Ncsplus Incorporated Electrician
Ncsplus Incorporated, 110 E 30th St, Manhattan, NY (Employees: Chandrapaul Bharratt, Chandrapaul Bharratt, and Sookdeo Ramjag) holds a Electrician license and 2 other licenses according to the New York license board.
Their BuildZoom score of 111 ranks in the top 4% of 77,888 New York licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Ncsplus Incorporated, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Ncsplus Incorporated Contact Information
Phone Number: (212) 213-3000
Address: 110 E 30th St, Manhattan, NY 10016
This is a sample of this contractor's permits. Click here to access their complete permit history.
Installation of new service feeders panels branch circuit wiring for all power lighting & receptacles for new 39 apartments 11 story building. this app supersedes app # x01112854-i1-el and x00898717-i1-el to be closed upon inspection. includes power to line side of elevator disconnect only. this app is based on the 2011 nyc code
Valuation:
N/A
Permit #:
X01198176-I1-EL
Status:
issued
Fee:
$4,707
Permit Type:
N/A
Building Type:
L five or more fa...
Install conduit and cat # 6 wiring for new camera system throughout building. install. install (1) 20amp and (1) 30amp receptacle with branch circuit for camera equipment
Valuation:
N/A
Permit #:
B01014132-I1-EL
Status:
issued
Fee:
$40
Permit Type:
N/A
Building Type:
W school
Install conduit and cat #6 wiring for new digital camera system throughout building. replace (5) existing quad receptacles on existing branch circuits for camera equipment
Valuation:
N/A
Permit #:
B01014105-I1-EL
Status:
issued
Fee:
$40
Permit Type:
N/A
Building Type:
W school
Install new 400amp meter disconnect feeder (3) new panelboards lighting and power for medical space on 5th floor. also electrical plan review job # mn02478a1
Valuation:
N/A
Permit #:
M01016465-P2
Status:
approved
Fee:
$543
Permit Type:
N/A
Building Type:
I hospital or hea...
Install new 400amp meter disconnect feeder (3) new panelboards lighting and power for medical space on 5th floor. also electrical plan review job # mn02478a1
Valuation:
N/A
Permit #:
M01016465-I1-EL
Status:
issued
Fee:
$514
Permit Type:
N/A
Building Type:
I hospital or hea...
Install 100amp disconnect with new feeder and panelboard with new branch circuits for new walk-in refrigerator and freezer work
Valuation:
N/A
Permit #:
B01194002-I1-EL
Status:
issued
Fee:
$120
Permit Type:
N/A
Building Type:
W school
Pickup app #: b311311 work started by others. service work risers panels and branch circuits in apartments and hallways. power to split air conditioning units etc
Valuation:
N/A
Permit #:
B00883852-I1-EL
Status:
issued
Fee:
$5,040
Permit Type:
N/A
Building Type:
L five or more fa...
Pickup app #: b311311 work started by others. service work risers panels and branch circuits in apartments and hallways. power to split air conditioning units etc
Valuation:
N/A
Permit #:
B00883852-P1
Status:
approved
Fee:
$5,000
Permit Type:
N/A
Building Type:
L five or more fa...
Install conduit and cat #6 wiring for new digital camera system throughout building. replace (5) existing quad receptacles on existing branch circuits for camera equipment
Valuation:
N/A
Permit #:
B01014105-P2
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
W school
Install new 2/0 feeder panelboard & receptacles for new camera system. install new conduit & cat# 6 for new cameras throughout per design drawings
Valuation:
N/A
Permit #:
M00935118-I1-EL
Status:
complete
Fee:
$135
Permit Type:
N/A
Building Type:
W school
Provide (10) powerpack with modules to control existing lights in auditorium ceiling and install power for new projector screen above stage
Valuation:
N/A
Permit #:
B00902005-I1-EL
Status:
complete
Fee:
$40
Permit Type:
N/A
Building Type:
W school
Disconnect power to existing boilers. install new branch circuits from existing panel for circulator pumps and draft inducer in boiler room
Valuation:
N/A
Permit #:
Q00919593-I1-EL
Status:
issued
Fee:
$40
Permit Type:
N/A
Building Type:
W school
Install new panel with new feeder and new branch circuits with disconnect switches for new split air conditioning systems in auditorium
Valuation:
N/A
Permit #:
B00816217-I1-EL
Status:
complete
Fee:
$217
Permit Type:
N/A
Building Type:
W school
Replace existing panel install new branch circuit for new light fixtures and quad receptacle for new local sound system in auditorium
Valuation:
N/A
Permit #:
B00896061-I1-EL
Status:
issued
Fee:
$56
Permit Type:
N/A
Building Type:
W school
Install new branch circuits with receptacles from existing panelboard for new walk-in freezers
Valuation:
N/A
Permit #:
M01196249-I1-EL
Status:
issued
Fee:
$40
Permit Type:
N/A
Building Type:
W school
Install new disconnect feeder and panel with branch circuits for power multimedia room # 219/225
Valuation:
N/A
Permit #:
Q01163774-I1-EL
Status:
issued
Fee:
$215
Permit Type:
N/A
Building Type:
W school
Install (6) new panels with feeders and new branch circuits with new light fixtures and receptacles for medical office on 4th floor
Valuation:
N/A
Permit #:
M00744317-P1
Status:
approved
Fee:
$584
Permit Type:
N/A
Building Type:
I hospital or hea...
Install new branch circuit with receptacles and lights for new sunroom in rear. this app is in conjunction with job # q00887722-i1
Valuation:
N/A
Permit #:
Q01120295-I1-EL
Status:
complete
Fee:
$40
Permit Type:
N/A
Building Type:
A one family
Install new lights power receptacles and data to replace existing for renovation of library
Valuation:
N/A
Permit #:
B01068075-P1
Status:
approved
Fee:
$87
Permit Type:
N/A
Building Type:
W school
Install new receptacles with branch circuits from existing panelboard for scoreboard in gym
Valuation:
N/A
Permit #:
X01199878-I1-EL
Status:
issued
Fee:
$40
Permit Type:
N/A
Building Type:
W school
Ncsplus Incorporated Reviews
BuildZoom hasn't received any reviews for Ncsplus Incorporated. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Hiring a contractor?
Verified License
BuildZoom confirmed this contractor's license
Ncsplus Incorporated License info
Verified License
| License # | 013288 |
| Status | Active |
| State | New York |
| Type | Electrician |
- BuildZoom verified this license was active as of December 2025.
Verify this license's status for Ncsplus Incorporated at the New York City Department of Buildings.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | 004545 |
| Status | Active |
| State | New York |
| Type | Electrical Firm |
- When BuildZoom last verified this license, it had an expiration date of December, 2023. Check the current license status of Ncsplus Incorporated with the New York City Department of Buildings
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | 012708 |
| Status | Active |
| State | New York |
| Type | Electrician |
- When BuildZoom last verified this license, it had an expiration date of August, 2023. Check the current license status of Ncsplus Incorporated with the New York City Department of Buildings
This is a sample of licensing data; click here to access a complete history.
111
BuildZoom Score
Insured
| Insurer | Nationwide Ins Company |
Insured
| Workers Comp Provider | Norguard Insurance Compan |
126
Permits
- Building permit records show that Ncsplus Incorporated has worked on 126 permitted projects.
Ncsplus Incorporated Employees
CB
Chandrapaul Bharratt
Responsible Rep
CB
Chandrapaul Bharratt
Responsible Rep
SR
Sookdeo Ramjag
None