Updated: May 10, 2025
Location and Projects
Address
301 Blair Ave, Reading, PA, 19601
Use our bidding system to
request a quote
Orlando Electric Service, Inc
When you need electrical repair or installation, have it done safely and affordably by the Master Electricians of Orlando Electric Service, Inc. of Reading. Workmanship you can trust.
From BuildZoom:
Their BuildZoom score of 0 does not rank in the top 50% of Pennsylvania contractors.
If you are thinking of hiring Orlando Electric Service, Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Orlando Electric Service, Inc Services
Start a project today:
Orlando Electric Service, Inc Contact Information
Phone Number: (610) 373-5856
Address: 301 Blair Ave, Reading, PA 19601
Building Permits by Orlando Electric Service, Inc
This is a sample of this contractor's permits. Click here to access their complete permit history.
2nd fl hall & 2 bedrms - addition hardwired inter connected smoke alarms replace all existing devices with new replace 100 amp service cable to existing panel box. address 1053 pershing blvd - parcel # under 1001 scott st. same prop per notes on written app. approved by tw/jm
Valuation:
$2,000
Permit #:
42108
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
2nd floor hall (2) bedrooms hardwire inter converted smoke alarms replace all existing devices with new replace 100 amp service cable to existing panel box. property address 1055 pershing blvd-parcel under 1001 scott st per notes on permit app. approved by tw/jm
Valuation:
$2,000
Permit #:
42107
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
10-electrical hardwire smoke detectors replace existing 100 amp panelbox with new 100 amp panel box grounding of earth and water service install dedicated circuits to 5 bedrooms isa afci 1-bathroom 20amp 120 volt all mounted in a junction box in drop ceiling area cmk
Valuation:
$2,800
Permit #:
25722
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
1st floor apartment - added a wall switch and ceiling light fixtures. replace electric 5 baseboard heater that was damaged. 1st floor rear apartment - kitchen replaced existing outlet with a gfci outlet. added (1) outlet in rear room. approved by tw jm
Valuation:
$500
Permit #:
48985
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Replace (5) existing electric interconnected smoke alarm dgtgctcas. (3) hallway + (2) basement. 1st floor rear apartment installed a gfci outlet at kitchen sink (existing) 2nd floor apartment installed a gfci outlet at bathroom (existing). approved by tw jm
Valuation:
$500
Permit #:
48110
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Basement-electric water heater circuit electric dryer circuit washer circuit grouding of earth & water system. kitchen - (2) 20 amp circuits & (2) outlets dining room - (1) 20 amp circuit & (2) outlets. 2nd floor rear bedroom - 15 amp afci circuit and (3) outlets. 2nd floor bathroom - 20 amp circuit and gfci outlet. approved by tw jm
Valuation:
$3,000
Permit #:
47488
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Basement- added a 8 space sub panelbox. insalled existing 2nd floor kitchen circuit wires into sub panelbox & terminate under circuit breakers. 2nd floor kitchen- intalled switches outlets & gfci outlets to existing electrical wires at countertop area. installed (1) ceiling fixture and (1) wall fixture to existing electrical wires. all wiring was existing. approved by tw jm
Valuation:
$750
Permit #:
46882
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Replaced (2) 100 fuse panel boxes with (2) 100 circuit breaker panel boxes. replaced (2) 100 fuse disconnects with (2) 100 main breaker disconnects. hallway - added (2) combo energ. lights & exits & (4)emerg light packs. lis approved by tmwald
Valuation:
$2,000
Permit #:
35601
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Dinging area - new 100a 10 mg feeder from man electric panel box to dining room new 100a 20 space panelbox (40) now 20 amp 120 volt circuits & surface mounted outlet - (1) wall switch and ceiling fan. approved by tw jm
Valuation:
$2,500
Permit #:
55626
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial
100-amp service & 100 amp panelbox. house - replace all existing outlets switches and fixtures with new (existing wires) kitchen 20a circuit and (2) gfci's 1st & 2nd floor bathroom - 20 a circuit and (2) gfci's outlets. approved tfw dao
Valuation:
$3,000
Permit #:
38192
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Addition 1-100 amp overhead service and 100 amp panelbox 1st 2nd & 3rd fl- addition electric circuits for water heater and electric stoves basement- move owners circuit into new owners panelbox cmk approved by tim w
Valuation:
$2,500
Permit #:
32740
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
2nd fl hall & 2 bedrooms - hanrd wired interconnect smoke alarms. replace all existing devices with new. replace 150 amp service cable to existing panel box. approved tfw/dao this is for 1045 pershing blvd
Valuation:
$2,000
Permit #:
41582
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial
2nd floor floor hall & 2 bedrooms-hardwired interconnect smoke alarms replace all existing devices with new replace 150 a service cable to existing perelbex. approved by tfw/ss.this is for 1047 pershing blvd
Valuation:
$2,000
Permit #:
41074
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
200 amp overhead electric service + 200 amp main breaker panel box. grounding of water & earth met-ed dr #341-203-046 (work is complete). approved by tw jm
Valuation:
$2,000
Permit #:
56440
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Grounding of earth & water service to existing electrical service panel box. electrical inspection needed for met-ed utility re-connect. (permit originally submitted in mobile-eyes) approved by tw jm
Valuation:
$400
Permit #:
47178
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial
Basement-add 60 amp 6-13 space sub panelbox 2nd fl frt 2nd fl middle 2nd rear 3rd front & rear bedrooms- addition new surface mounted outlets as needed with arc fault breakers cmk approved by tim w
Valuation:
$2,000
Permit #:
34713
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
100 amp overhead electric service & 100 amp panelbox 2nd floor bathroom - 20 amp 120v circuit and gfci outlet at vanity kitchen - replace 2 existing outletw with gfci outlets cmk approved by tim w
Valuation:
$1,500
Permit #:
34156
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Existing 100 amp panelbox for 2nd fl wiring replace with a new 100 amp 20 space main breaker panelbox grounding of water service basement install 7 new lights with a switch at top of stairs cmk
Valuation:
$1,000
Permit #:
26234
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
200a u.g. main breaker diconnect with a 3 gang meterbase. 1st floor 337-680-439 2nd floor 337-679-524 owner (now) 337-679-580. lockbox @rear bilco door #7696 manted on wall. approved by tw jm
Valuation:
$2,000
Permit #:
51893
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Floor #1 bathroom - secured wiring at switch box floor #1 - room #5 bed - installed existing exposed wiring at doorway into a surface mounted junction box w/switch. approved by tw jm
Valuation:
$150
Permit #:
44349
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Residential
Orlando Electric Service, Inc Reviews
BuildZoom hasn't received any reviews for Orlando Electric Service, Inc. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Orlando Electric Service, Inc License info
License Not Verified
| HIC # | PA012782 |
| Status | Active |
| State | Pennsylvania |
| Type | Installing Electrical Wiring And Equipment For New And Old Work, Residential And Commercial Electrical Contractor. |
- When BuildZoom last verified this license, it had an expiration date of July, 2017. Check the current license status of Orlando Electric Service, Inc with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | PA012782 |
| Status | Inactive |
| State | Pennsylvania |
- According to the Pennsylvania Office of the Attorney General, the status of this license was at one point cancelled. However, this information may have changed.
Check this license's status for Orlando Electric Service, Inc at the Pennsylvania Office of the Attorney General.
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are Orlando Electric Service, Inc, log in and update your license info in the “Edit Profile” tab.
Insured
| Insurer | Mgs Insurance Agency, Llp |
| Insured up to | $1,000,000 |
84
Permits
- Building permit records show that Orlando Electric Service, Inc has worked on 84 permitted projects.
Orlando Electric Service, Inc Employees
DD
Donald Dietrich
Owner
DJ
Donald L. Dietrich Jr
Owner/President 100