Updated: May 10, 2025
Location and Projects
Address
602 POMONA HILL DR, West Chester, PA, 19382
Use our bidding system to
request a quote
Petyk Electric LLC
Petyk Electric LLC, 602 Pomona Hill Dr, WEST CHESTER, PA (Employee: Stephen Petyk) holds a Electrical Contractor license and 2 other licenses according to the Philadelphia license board.
Their BuildZoom score of 92 ranks in the top 32% of 125,106 Pennsylvania licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Petyk Electric LLC, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Petyk Electric LLC Contact Information
Phone Number: (610) 574-2025
Edit
Address: 602 POMONA HILL DR, WEST CHESTER, PA 19382
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Install 9pendant fixtures, 15ft of track lighting with 12track heads, install 9recessed fixtures, 4exit signs, 3emergency packs, 9single pole switches, provide and install 36recepts and provide and install cat5e wiring for 4camera locations and 5pos terminals, partially rewire space to control new lighting and new recepts as per 2008 nec
Valuation:
N/A
Permit #:
600390
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace existing 100amp service cable, meter socket and panel, replace existing devices in basement and 1st floor to include 20recepts, 15switches and 4gfci's, rewire 2nd floor, install 17recepts, 3ceiling fans, 8switches and 1gfci, install 7-120v with battery backup smoke and co detectors as per 2008 nec
Valuation:
N/A
Permit #:
600388
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install fire alarm install 3000 amp service & complete fit out of apartment (1st floor commerical space excluded) as per nec 2008 & nfpa 72 (mixed use)
Valuation:
N/A
Permit #:
539783
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Iunstall 200 amp service - 63 receptacles - 9 recessed lights - 7 smoke detectors - 42 switches - 3 exhaust fans - 2 weatherproof gfis - 6 gfci receptacles - 19 surface fixtured - as per 2008 nec
Valuation:
N/A
Permit #:
472571
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 36 striplights, 18 ecessed fixtures, 6 wall lights and 4 pole lights. remove 6 existing pole lights and 4 column lights.provide power for motorized doors as per 2008 nec (hotel)
Valuation:
N/A
Permit #:
425038
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Rewire throughout & upgrade service to 200amp install hardwired w/battery smoke & co detectors as per nec 2008 (sfd) north district
Valuation:
N/A
Permit #:
574384
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install replace 4 recessed fixture replace air conditioning compressor disconnect replace 3 surface mounted fixtures replace 4 recessed trims replace smoke detector and replace gfci and weatherproff cover per 2008 nec
Valuation:
N/A
Permit #:
417126
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove 364 vanity fixtures & reinstall remove 364 wall fixtures in room & reinstall remove 105 wall fixtures in hall & reinstall as per nec 2008 (hotel)
Valuation:
N/A
Permit #:
490290
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
24 switches 35 receptacles 8 smokes detectors 2 smoke/co2 detectors 10 recess lights 7 surface fixtures 2 exhaust fans 8 gfci arc fault breakers where required as per 2008 nec 1 family dwelling
Valuation:
N/A
Permit #:
379260
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Rewire 28 apts, new 800 amp svc, new panelsin all units, afci breakers, tamper proof receptacles, smoke & c/o detectors in units, common area & emergency lighting. *no fire alarm work on this permit*
Valuation:
N/A
Permit #:
356890
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace breaker box and (20)breakers. install (36)recessed lights (42)receptacles (25) switches (5)ceiling fans and re-wire residence. install (8)interconnected smoke detectors with battery back-up. in accordance with 2005 nec
Valuation:
N/A
Permit #:
234219
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 15 fixtures 19 switches 35 tamper receptacles 8 gfci receptacles 6 smokes detectors 2 co/smoke detectors and 200amp aerial service per 2008 nec (sfd)
Valuation:
N/A
Permit #:
439993
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove existing hall lighting fixtures and replace with new fixtures as per 2008 nec (cc district)
Valuation:
N/A
Permit #:
577329
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 17 fixtures 19 sws 26 tamper proof receptacles 8 gfci receptacles 4 smoke detectors 2 co2/smoke combination detectors 200 amp service as per 2008 nec (north dist)
Valuation:
N/A
Permit #:
354467
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 17 fixtures 19 sws 26 tamper proof receptacles 8 gfci receptacles 4 smoke detectors 2 co2/smoke combination detectors 200 amp service as per 2008 nec (north dist)
Valuation:
N/A
Permit #:
354471
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 706 fixtures, 58 receptacles, rewire 6 hvac compressor and 364 ptac units per 2008 nec (hotel)
Valuation:
N/A
Permit #:
504189
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install new service cable, 3 gang meter socket and two disconnects per 2008 nec (three family)
Valuation:
N/A
Permit #:
504188
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire alarm installation: 1-silent knight 5208 3-horn strobes, 4-horn sounders, 5-system sensor ul268 smoke detectors, 1-system sensor heat detector 6 pull stations as per nfpa-72 (north dist)
Valuation:
N/A
Permit #:
253349
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 1 facp 1 annunicator 5 pull stations 1 smoke detectors 9 horm strobes and 6 strobe only per nfpa 72
Valuation:
N/A
Permit #:
417128
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 17 fixtures, 19 switches, 26 receptacles, 8 gfci, 4 smoke detectors, 2 co/smoke detectors, 200 amp service, 100amp temp service as per 2008 nec
Valuation:
N/A
Permit #:
318310
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
HIC # 053629
Philadelphia, PA
131
BZ Score
$8.5K
Avg Project
-
Projects
130
BZ Score
$2.2K
Avg Project
-
Projects
149
BZ Score
$10K
Avg Project
-
Projects
Petyk Electric LLC Reviews
BuildZoom hasn't received any reviews for Petyk Electric LLC. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Verified License
BuildZoom confirmed this contractor's license
Petyk Electric LLC License info
Verified License
| HIC # | 17736 |
| Status | Active |
| City | Philadelphia |
| Type | Electrical Contractor |
- BuildZoom has not verified this license since August, 2015.
Verify this license's status for Petyk Electric LLC at the City of Philadelphia Licensed Contractors.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| HIC # | PA071528 |
| Status | Active |
| State | Pennsylvania |
| Type | Commercial And Residential Electrical Contractor. Fire Alarm Contractor. Complete Rewire And Services, Life Safety, Specialty Lighting, Computer Networking, And Maintenance Services. |
- When BuildZoom last verified this license, it had an expiration date of December, 2016. Check the current license status of Petyk Electric LLC with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | PA071528 |
| Status | Inactive |
| State | Pennsylvania |
- According to the Pennsylvania Office of the Attorney General, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Petyk Electric LLC at the Pennsylvania Office of the Attorney General.
This is a sample of licensing data; click here to access a complete history.
92
BuildZoom Score
Insured
| Insurer | Selective Insurance Of North America |
| Insured up to | $1,000,000 |
34
Permits
- Building permit records show that Petyk Electric LLC has worked on 34 permitted projects.
Petyk Electric LLC Employees
SP
Stephen Petyk
Owner/President