Location and Projects
Address
Cheyenne, WY, 82003
Use our bidding system to
request a quote
Phoenix Fire Protection
Phoenix Fire Protection at Cheyenne, WY 82003, has a BuildZoom score of 90 and ranks in the top 53% of 1,897 Wyoming contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Phoenix Fire Protection Contact Information
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Building Permits by Phoenix Fire Protection
This is a sample of this contractor's permits. Click here to access their complete permit history.
Will be putting the system back in the hood that was pulled from the old jacksons sports bar and put in at ikes. the system will have 4.5 gallons of chemical remote pull station 1 1/2 mechanical gas valve and 5 detection brackets with fusible links. plumbing and electrical work to be completed by others
Valuation:
$3,000
Permit #:
BP-21-01155
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove fire sprinkler system from the kitchen hood and install an ansul r-102 ul-300 compliant system. system will include 6 gallons of chemical remote pull station and gas valve. electrical hookups will be completed by signature electric
Valuation:
$10,886
Permit #:
BP-21-01154
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Re pipe nozzle drops and pipe in second hood to fire system addition 1-3 gal tank to system change cartridge to proper size far new system configuration this work is being conducted on an existing ansol r102 system in pre existing hoods
Valuation:
$3,470
Permit #:
BP-20-02216
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Hook up and commission an ansul r102 ul300 compliant system in a prepiped hood.system will include a remote pull station gas valve and 5 detectors. gas valve and electrical will
Valuation:
$1,849
Permit #:
BP-21-00883
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install an ansul r102 ul300 compliant system into a food trailer. system will include a 3/4 mechanical gas valve remote pull station and 3 gallons of chemical
Valuation:
$3,927
Permit #:
BP-21-01674
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install an ansul r102 ul300 compliant system in hood system. this will be a 6 gallon system. using 18 flow points. 1 mechanical. gas valve 1 dpdt micro switch and 1 remote pull station
Valuation:
$4,000
Permit #:
BP-18-02372
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Hook up an ansul r102 ut300 compliant kitchen hood supression system in a pre-piped hood
Valuation:
$1,546
Permit #:
BP-19-02154
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install a new amerex drypowder system in a new paint booth and paint mixing room
Valuation:
$12,811
Permit #:
BP-19-04382
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install an ansul r102 ul 300 listed pre-engineered system in a pre-piped hood. gas valve and electrical will be installed by other sub contractors
Valuation:
N/A
Permit #:
BP-17-00835
Status:
complete
Fee:
$100
Permit Type:
N/A
Building Type:
N/A
Addition fire sprinkler system system to provide coverage in space above entry ways (3)
Valuation:
$74,500
Permit #:
BP-15-03341
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Re-pipe appliance drops for new appliance lay out. addition additional links per protection. install new system bottle & cover new flow points
Valuation:
$1,761
Permit #:
BP-17-00882
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Service system and test for proper function
Valuation:
$204
Permit #:
BP-16-01226
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install an ansul r102 ul300 compliant system in a pre-piped hood. in kitchen in new addition
Valuation:
N/A
Permit #:
BP-17-00710
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Complete a tenant finish to the sprinkler system
Valuation:
$6,000
Permit #:
BP-15-03559
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 2 ansul r102 systems in pre-piped hoods. protection is for duct and plenum only no appliances need protection. we will install micro switches for connection to control box and alarm. gas valve will be installed and connected to the system. remote pull station will be installed
Valuation:
$5,687
Permit #:
BP-20-01010
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install a new amerex industrial system in a new paint booth and paint mixing room. this is a dry powder system with 4 tanks and 7 links. 1 45# tank with cover the main area with 2 nozzles. 2 18# tanks will cover the 2 duct and plenums and 1 18# tank will cover the mixing room. the system will have an alarm bell on it and a mechanical time delay in the actuation line. system is ul1254 ... see more
Valuation:
$8,368
Permit #:
BP-19-00349
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install a new amerex industrial system in a new paint booth and paint mixing room. this is a dry powder system with 4 tanks and 7 links. 1 45# tank with cover the main area with 2 nozzles. 2 18# tanks will cover the 2 duct and plenums and 1 18# tank will cover the mixing room. the system will have an alarm bell on it and a mechanical time delay in the actuation line. system is ul1254 ... see more
Valuation:
$7,982
Permit #:
BP-19-00348
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove fire sprinkler system from the kitchen hood and install an ansul r-102 ul-300 compliant system. system will include 9 gallons of chemical remote pull station and gas valve. plumbing and electrical work to be completed by others
Valuation:
$10,139
Permit #:
BP-21-00516
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace pre ul-300 control head and bottle with ul-300 compliant parts
Valuation:
$883
Permit #:
BP-15-01797
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Put the hood system back in install tank and pull station. hookup gas valve to the control box. re-run the link line and redo the appliance line distribution piping for the new appliance layout. this hood has had a system installed in it prior but most was removed. re-installing it to ul300 and nfpa17a standards
Valuation:
$3,800
Permit #:
BP-20-00403
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors
License not required
Cheyenne, WY
90
BZ Score
-
Avg Project
-
Projects
License # CT-10-02742
Cheyenne, WY
104
BZ Score
$17K
Avg Project
-
Projects
License # CT-26-02853
Cheyenne, WY
90
BZ Score
-
Avg Project
-
Projects
Phoenix Fire Protection Reviews
BuildZoom hasn't received any reviews for Phoenix Fire Protection. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Phoenix Fire Protection License info
License Not Required
| Status | Not Required |
- BuildZoom verified in September, 2020 that this contractor does not need a license to be a specialist in Wyoming.
This is a sample of licensing data; click here to access a complete history.
90
BuildZoom Score
34
Permits
- Building permit records show that Phoenix Fire Protection has worked on 34 permitted projects.