Updated: May 06, 2026
Location and Projects
Address
1080 Co Rd 363, Granger, TX, 76530
Use our bidding system to
request a quote
plumbingOutfitters
plumbingOutfitters, 1080 Co Rd, Granger, TX (Owned by: John Stroud) holds a Plumber license and 1 other license according to the Texas license board.
Their BuildZoom score of 109 ranks in the top 5% of 222,249 Texas licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring plumbingOutfitters, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
plumbingOutfitters Contact Information
Phone Number: (512) 269-1382
Address: 1080 Co Rd 363, Granger, TX 76530
This is a sample of this contractor's permits. Click here to access their complete permit history.
Plumbing permit - commercial gas test/repairs (101-000-4210)
2025-06-25
Water line & sewer line repair - the trenches run southwest to northeast across the property. the trenching begins directly behind our office and extends through the parking lot to the northeast corner of the property.two trenches run parallel to each other approximately 6 feet apart.the water line includes a branching “arm” that connects to the main line about 100 feet into the run.t... see more
Valuation:
N/A
Permit #:
2025-41443
Status:
issued
Fee:
N/A
Permit Type:
Repair/replacement
Building Type:
Mechanical reside...
Tunnel repair on drain system excavate entry holes at the front-left and back-right of the house. from these access points we will tunnel approximately 85 feet beneath the foundation to reach and expose the identified diagnostic area the existing drains will be replaced with new dwv schedule 40 pvc pipe and fittings installed in full compliance with plumbing code. all piping will be p... see more
Valuation:
N/A
Permit #:
FY-25-350-PBRR
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Plumbing permit - water heater install/changeout permit (101-000-4210) (effective feb. 1 2024)
2025-08-11
Scope of work:tankless water heater installation & relocationremove the existing water heater.install a new tankless water heater relocate the water heater to the garage for easier access and improved functionality.run new water gas and vent connections as required to complete installation in the garage
Valuation:
N/A
Permit #:
2025-41719
Status:
issued
Fee:
N/A
Permit Type:
Repair/replacement
Building Type:
Mechanical reside...
Sewer yard line repair sewer yard line repair revealed clay piping with multiple breaks. work will begin by excavating from the house—cutting through the concrete pad—to the city tap in the alley (approx. 60 ft). damaged sections will be replaced with new schedule 40 dwv pvc pipe and fittings
Valuation:
N/A
Permit #:
FY-25-261-PBRR
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Drain spot repair tunnel from the front left corner of the home extending 10 ft to access the broken fitting. centex will expose a 3x2 wye beneath the garage floor including several feet in both the 3” and 2” directions of the main/kitchen drain line. we will replace the wye up to the cleanout—the cleanout itself will not be replaced
Valuation:
N/A
Permit #:
2025-396
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Tunnel spot repairdiscovered a break in the master bathroom tub drain and a break in the master bathroom shower vent. proceeded to tunnel approximately 5 feet beneath the home’s foundation to access and expose the identified issues for repair
Valuation:
N/A
Permit #:
2025-562
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Plumbing permit - commercial gas test/repairs (101-000-4210)
2025-05-01
Water reroute: the new line will be ran from the water heater all the way into that break room sink to get water back to the that sink and the other sink in the break room
Valuation:
N/A
Permit #:
2025-41081
Status:
issued
Fee:
N/A
Permit Type:
Repair/replacement
Building Type:
plumbing commercial
Plumbing permit - residential gas test/repairs (101-000-4210)
2024-06-27
Tunnel repair on drain system: diagnostic revealed a section of cast iron that has completely rusted out the bottom of the pipe. we will be excavating entry hole(s) at the back middle of the house near the steps of the back porch. then we will tunnel underneath the foundation of the house approximately 25 feet to access and expose noted diagnostic issue
Valuation:
N/A
Permit #:
2024-39034
Status:
issued
Fee:
N/A
Permit Type:
Repair/replacement
Building Type:
Mechanical reside...
Plumbing permit - water softener installations permit (101-000-4210)
2024-01-03
Install water softener loop in yardinstallation of water softener loop. we will start by running two 1” pex water lines across the attic from the right side if the home to the garage where the water softener will be located. the wall in the bedroom will need to be cut and the wall in the garage will need to be cut at the location of the softener. then trench in the yard from the water... see more
Valuation:
N/A
Permit #:
2024-37897
Status:
issued
Fee:
N/A
Permit Type:
Repair/replacement
Building Type:
plumbing residential
Dig an entry hole on the right side of the building tunnel under the bathroom to locate the kitchen sink drain and follow the kitchen drain appropriately 10’ total of 15’ tunnel from the entry hole once the drain is exposed remove the bellied section of the kitchen drain and replace with new 2” pvc pipe and fittings anchor the exposed piping to the foundation before backfill of the tu... see more
Valuation:
N/A
Permit #:
2024-9669
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Plumbing permit - residential gas test/repairs (101-000-4210)
2023-03-22
Rerouting of hot water line in foundation to eliminate leaking pipe. slab leak on a 3/4” hot water line and a split on a 1/2” hot water line near the foundation. begin by accessing sheetrock in the pantry and the front living room ceilings.then we will abandon leaking water line in foundation. water line will be rerouted overhead in the subfloor between the pantry and the downstairs p... see more
Valuation:
N/A
Permit #:
2023-36011
Status:
issued
Fee:
N/A
Permit Type:
Repair/replacement
Building Type:
plumbing residential
Plumbing permit - repair - this estimate is to replace a broken fitting in the front yard of the property. this fitting is on the main 4 inch sewer line. this estimate is only valid if the hole is already been dug exposing enough of the main sewer line in order to make the repair. once the repair is made we will test the fitting to ensure no leaks are found and proper drainage is allo... see more
Valuation:
N/A
Permit #:
2022-153815 PP
Status:
issued
Fee:
$48
Permit Type:
Residential
Building Type:
N/A
Plumbing permit - repair - leaking 1/2 cold copper water line will be abandoned under the foundation. we will connect to the main cold water manifold and run 1/2 pex pipe up in between floors and down to the kitchen sink. also the hose bib will be connected that is behind the kitchen sink. the run will be a total of about 50 ft pipe will be well strapped and insulated. we will also re... see more
Valuation:
N/A
Permit #:
2022-152508 PP
Status:
issued
Fee:
$48
Permit Type:
Residential
Building Type:
N/A
Plumbing permit - addition and remodel - addition remodel to existing 1-story single family residential to include: partial garage conversion to utility room half bath; interior remodel; retroactively permitting rear uncovered wood deck. - r- 434 addition & alterations
Valuation:
N/A
Permit #:
2022-130878 PP
Status:
issued
Fee:
$227
Permit Type:
R- 434 addition &...
Building Type:
N/A
Plumbing permit - repair - remove wash machine and jackhammer through the floor. will have to dig down and then dig over 2 feet to access broken p-trap. repair broken pipe and run new section of pvc up to washer box. tie onto cashed out under the house. if cast-iron is not in good condition then additional estimates may be given. after repair is done we will backfill and pour concrete... see more
Valuation:
N/A
Permit #:
2022-094298 PP
Status:
issued
Fee:
$130
Permit Type:
Residential
Building Type:
N/A
Plumbing permit - repair - cust1 cut out and remove section of cast iron drain system for bathroom underneath pear and beam home. rough in new pvc 4 and 2 sanitary drain system for toilet tub and reconnect pvc kitchen drain. a test tee will be installed on new section of drain for city inspection and test. new pvc piping will connect to existing cast iron drain stubbing down through f... see more
Valuation:
N/A
Permit #:
2022-050846 PP
Status:
issued
Fee:
$80
Permit Type:
Residential
Building Type:
N/A
Plumbing permit - repair - correct tankless heater and installed pressure reducing valve. pull city of austin permit for inspection. excavate water service yard line on house side of water meter. provide and install new pressure reducing valve on water line. after installation unit will be tested and set. hole will be backfilled with valve box over prv. correct tankless heater. 1) shu... see more
Valuation:
N/A
Permit #:
2022-050849 PP
Status:
final
Fee:
$53
Permit Type:
Residential
Building Type:
N/A
Plumbing permit - repair - customer requested water service connection so construction can begin. a trench will be hand dug from water meter underneath chain link fence roughly 4. a 1 pex water line will be ran from meter nipple up to other side of fence. water line will be equipped with new home owner 1/4 turn ball valve and hose bib. trench will be backfilled and valve box places ar... see more
Valuation:
N/A
Permit #:
2022-050935 PP
Status:
triage
Fee:
$53
Permit Type:
Residential
Building Type:
N/A
Plumbing permit - repair - 106. repair failed section of 3/4 copper water line in back left corner of garage wall. replace 3/4 cut off valve in ground outside unit. customer will have bricks pulled up and line exposed. water will need to be shut down to entire property for valve replacement. after repair are made water will be turned back onto property and units 102&106 for testing. i... see more
Valuation:
N/A
Permit #:
2022-046453 PP
Status:
final
Fee:
$53
Permit Type:
Commercial
Building Type:
N/A
Plumbing permit - repair - 102. repair leaking 1/2 copper water line in kitchen wall of unit 102. cabinet and wall boards sill be removed by customer. 1/2 piping will connect to piping in wall as well as stubbed out with new stop. line will be secured in wall. cold water angle stop will also be replaced. water will be turned back into building and tested. after repair are made water w... see more
Valuation:
N/A
Permit #:
2022-046418 PP
Status:
final
Fee:
$53
Permit Type:
Commercial
Building Type:
N/A
plumbingOutfitters Reviews
BuildZoom hasn't received any reviews for plumbingOutfitters. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Verified License
BuildZoom confirmed this contractor's license
plumbingOutfitters License info
Verified License
| License # | 41984 |
| Status | Active |
| State | Texas |
| Type | Plumber |
- BuildZoom verified this license was active as of May 2026.
Verify this license's status for plumbingOutfitters at the Texas State Board of Plumbing Examiners.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | 7289 |
| Status | Inactive |
| City | Round Rock |
| Type | Contractor |
- According to the The City of Round Rock, TX , the status of this license was at one point cancelled. However, this information may have changed.
Check this license's status for plumbingOutfitters at the The City of Round Rock, TX .
This is a sample of licensing data; click here to access a complete history.
109
BuildZoom Score
Insured
| Insurer | CBIC |
| Insured up to | $1,000,000 |
158
Permits
- Building permit records show that plumbingOutfitters has worked on 158 permitted projects.
plumbingOutfitters Employees
JS
John Stroud
Owner