×

We'll help you find the right contractor.

Share your project details and we'll reach out to Quasar Energy Group so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Is this your business? Claim now >

Location and Projects

Headquarters Address
8600 E Pleasant Valley Rd, Independence, AZ, 44131
Local address
7624 RIVERVIEW RD, Brecksville, OH, 44141
Use our bidding system to request a quote

Quasar Energy Group Construction

Quasar Energy Group, 7624 Riverview Rd, Brecksville, OH (Owned by: Mel Kurtz) holds a license and 2 other licenses according to the Ohio license board.

Their BuildZoom score of 93 ranks in the top 27% of 52,717 Ohio licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Quasar Energy Group, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Quasar Energy Group Contact Information

Phone: (216) 986-9999 Edit
Headquarters Address: 8600 E Pleasant Valley Rd, Independence, AZ, 44131
Local Address: 7624 RIVERVIEW RD, Brecksville, OH 44141 Edit

Building Permits by Quasar Energy Group

Sort by: Notable Notable | Date Date | Job Value Job Value
Building/commercial/new construction/structural
2014-01-30
1/30/2014 - permit closed due to expired plan approval - see replacement permit #cbld1318352 - dbaxter-daniel 2500 jackson pike plan approval: final conditions of the plan approval: code: 2011 obc accessibility (1994 adaag ) use/occupancy (f-1) construction type (ii-b non-combustible unprotected) certificate of occupancy issued for the following : install a digestion tank at the north... see more
Valuation:
$1,400,000
Permit #:
CBLD1134006
Status:
complete
Fee:
$2,700
Permit Type:
N/A
Building Type:
N/A
Building/commercial/plans examination/plan revision
2014-06-12
Revision to cbld1318352 - addition storage tank concrete tanks enlarged biofilter addtional flare addition 2 site lights 6 alter driveway 7 addition truck load 8 small amount of process demolish 2500 jackson pike plan approval: final reviewed for compliance under: 2011 obc and icc a117.1-2009 work not included in this approval: mechanical use occupancy group: f-1 construction type: ii... see more
Valuation:
N/A
Permit #:
PLRE1412949
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Coo - new commercial
2012-04-19
B11013341 attached co new construct 59 diam feed tank 29'-8 diam digester tank 40 x 40 1 story structure for collinwood bioenergy ada facility bldge sep permit req'd for electric hvac plumbing. special insp req'd maintain fire hydrant system. permit-no superstructure work until approved pre-engineered superstructure plans in the field
Valuation:
$367,000
Permit #:
CO12007469
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building/commercial/new construction/structural
2014-09-29
2500 jackson pike plan approval: final reviewed for compliance under: 2011 obc and icc a117.1-2009 work not included in this approval: mechanical use occupancy group: f-1 construction type: iib description of the work: construct a 2.5 million gallon storage tank at the western end for the lot a two in ground concrete receiving tanks a biofilter istall two additional site lights and m... see more
Valuation:
$200,000
Permit #:
CBLD1318352
Status:
complete
Fee:
$3,300
Permit Type:
N/A
Building Type:
N/A
Commercial building permit
2012-08-15
New construct 59 diam feed tank 29'-8 diam digester tank 40 x 40 1 story structure for collinwood bioenergy ada facility bldge sep permit req'd for electric hvac plumbing. special insp req'd maintain fire hydrant system. permit-no superstructure work until approved pre-engineered superstructure plans in the field
Valuation:
$367,000
Permit #:
B11013341
Status:
final
Fee:
$5,104
Permit Type:
New construction
Building Type:
N/A
Commercial exterior alterations
2013-10-17
Installation of a mechanical separation system to remove contaminants from organic biomass to be processed. work include tank piping seperator and electrical paver components to be added to original system
Valuation:
$6,500
Permit #:
B12033992
Status:
issued
Fee:
$470
Permit Type:
Installation of a...
Building Type:
N/A
Building/commercial/plans examination/plan revision
2011-04-28
2500 jackson pike revision to permit#cbld1003716 including remove drinking fountain/add cooler addition double sink/revise boiler/add urinal addition shower/floor drains changed to trench drains/etc. 2500 jackson pike. anaerobic digestion facility. quasar energy group
Valuation:
$0
Permit #:
PLRE1110793
Status:
Closed
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Building/commercial/plans examination/plan revision
2010-10-13
2500 jackson pike. plan revision to building permit #cbld1003716. changes include increased size of t-001 & t-008 tanks relocation of tanks and miscellaneous building changes. anaerobic digestion facility. quasar energy group
Valuation:
N/A
Permit #:
PLRE1020158
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Lime lakes anaerobic digester addition obc 105.1.4 (d) phased (building only) approved for footing foundation building construction only no mechanicals) subject to adj#130567-a 6.20.13 jl obc 105.1.4 (d) phased (bl el hvac & pl only) approved for building construction and rough mechanicals only subject to adj#130567-b 7.11.13 jl obc 107.5.1 (a) full plan approval new franklin zoning #... see more
Valuation:
N/A
Permit #:
PB20132104
Status:
final
Fee:
$252
Permit Type:
New building
Building Type:
N/A
Storage tanks only building only quasar energy group-anaerobic digestion facility obc 107.5.1 (a) full approval 7.11.13 jl (building only) city of new franklin zoning#7827
Valuation:
N/A
Permit #:
PB20113701
Status:
final
Fee:
$211
Permit Type:
New building
Building Type:
N/A
Building/commercial/plans examination/plan revision
2010-10-06
2500 jackson pike. revision to building permit #cbld1003716 for electrical changes to anaerobic digestion facility. quasar energy group
Valuation:
N/A
Permit #:
PLRE1026765
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Commercial building permit
2016-03-23
Install cng fueling station per approved plans. separate electrical permit required. no occupancy permit is required
Valuation:
$19,000
Permit #:
B14020061
Status:
complete
Fee:
$480
Permit Type:
Alteration
Building Type:
N/A
Building/commercial/plans examination/plan revision
2009-02-19
2500 jackson pike revision to iunit0826111 upgrade of foundation for two tanks -t-001 and t-003
Valuation:
N/A
Permit #:
PLRE0903975
Status:
applied
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Building/master inspection/na/na
2013-06-07
No Description Available
Valuation:
N/A
Permit #:
MINSP1318004
Status:
applied
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Registration - contractor registration/new
2017-10-30
No Description Available
Valuation:
$0
Permit #:
CR17040473
Status:
Approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building/master inspection/na/na
2011-04-28
No Description Available
Valuation:
$0
Permit #:
MINSP1110718
Status:
N/A
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building/master inspection/na/na
2008-12-01
No Description Available
Valuation:
N/A
Permit #:
MINSP0825083
Status:
applied
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building/master inspection/na/na
2009-02-19
No Description Available
Valuation:
N/A
Permit #:
MINSP0903880
Status:
applied
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building/master inspection/na/na
2010-02-23
No Description Available
Valuation:
N/A
Permit #:
MINSP1003731
Status:
applied
Fee:
$150
Permit Type:
N/A
Building Type:
N/A
Building/commercial/minor alteration/re roofing
2018-05-14
Building permit to install a new aluminum frame and metal panel geodesic dome roof to cover an existing 2.6 million gallon 114ft diameter tank t-10 for central ohio bioenergy. rough and final structural inspections required to complete this permit. u iib
Valuation:
$200,000
Permit #:
RERF1703445
Status:
expired
Fee:
$450
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # NAT-F245782-1
150
BZ Score
$42.5K
Avg Project
-
Projects
License #
135
BZ Score
$17.5K
Avg Project
-
Projects
License not required
131
BZ Score
$12.5K
Avg Project
-
Projects

Quasar Energy Group Reviews

BuildZoom hasn't received any reviews for Quasar Energy Group. Click here to be alerted when reviews are posted about them.
Please write a review about Quasar Energy Group
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.