Updated: Nov 22, 2024
Location and Projects
Address
Somerset, MA, 02725
Use our bidding system to
request a quote
Raymond D Melanson Electric and Safety
Raymond D Melanson Electric and Safety, holds a license according to the Rhode Island license board.
Their BuildZoom score of 0 does not rank in the top 50% of Rhode Island contractors.
If you are thinking of hiring Raymond D Melanson Electric and Safety, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Raymond D Melanson Electric and Safety Contact Information
Phone Number: (508) 379-0859
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Raymond D Melanson Electric and Safety
Quality
Alert*
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
*No active license on file. If you are Raymond D Melanson Electric and Safety, click “This is My Business” to update your information.
Activity
|
13 projects
|
2024 |
|
29 projects
|
2023 |
Our building permit records indicate that Raymond D Melanson Electric and Safety has worked on at least
42.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
41 projects
|
Electrical projects |
Analyzing permits over the last 4 years shows that Raymond D Melanson Electric and Safety mostly works on
electrical project
projects.
Pricing
|
39 projects
|
< $5k |
|
1 project
|
$5k-$20k |
The typical size of their permits is approximately $1,500. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
Building Permits by Raymond D Melanson Electric and Safety
This is a sample of this contractor's permits. Click here to access their complete permit history.
-replace existing 2 pole 20 and 30 amp condenser feeds (bottom left mini breakers) with a 2 pole 25 and 35 amp. relocate condensers (currently behind one of the condensers) and reconnect. addition service outlet by condensers-reconnect 2- existing single pole 15 amp furnace feeds to newly replaced furnaces
Valuation:
$1,500
Permit #:
24-408
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-reconnect existing 2 pole 15 amp air handler feed to newly installed air handler-reconnect existing condenser feed currently 2 pole 30 amp (replace disconnect/whip) to newly installed 2 pole 35 amp condenser (switch breaker if possible)
Valuation:
$1,500
Permit #:
24-952
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-reroute existing single pole 15 furnace feed to newly installed furnace (and service outlet). new fire-o-matic and switch required
Valuation:
$1,500
Permit #:
86937
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-reconnect existing single pole 15 amp furnace feed to newly installed furnace (with service outlet)-relocate disconnect a few feet to the side reconnect existing 2 pole 30 amp condenser feed to newly installed condenser
Valuation:
$1,500
Permit #:
57737
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-reconnect existing single pole 15 amp furnace feed to newly installed furnace-reconnect existing 2 pole 40 amp breaker replace disconnect/whip to newly installed condenser
Valuation:
$1,500
Permit #:
13841
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-reconnect existing single pole 15 amp furnace feed to newly installed furnace-replace disconnect/whip reconnect preexisting 2 pole 30 amp condenser feed to newly installed condenser
Valuation:
$1,500
Permit #:
57703
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-replace existing condenser disconnect and whip (going from 2 pole 20 amp to a 2 pole 15)-reconnect new air handler to a 2 pole 15 amp circuit addition outlet at condenser and light in attic near air handler
Valuation:
$1,500
Permit #:
54720
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-installation of a 2 pole 40 amp mini split condenser feed-installation of single pole light and service outlet in attic space
Valuation:
$1,500
Permit #:
84609
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-reconnect existing single pole 15 amp furnace feed to newly installed furnace-replace disconnect/whip and reconnect newly installed condenser to existing 2 pole 20 amp condenser feed
Valuation:
$1,200
Permit #:
ELEC-22-1627
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-installation of a 2 pole 50 amp mini split condenser feed in place of a preexisting 2 pole 30 amp feed
Valuation:
$1,500
Permit #:
85258
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of fireomatic and swerve switch reconnect pre existing single pole 15 amp boiler feed to newly installed boiler
Valuation:
$1,500
Permit #:
57771
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Reconnect (3) existing 460 3 phase condenser feeds to (3) newly installed 25 amp condenser feeds to newly installed condensers
Valuation:
$1,500
Permit #:
56542
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Installation of 2 2 pole 30 amp condenser feeds and installation of 2 2 pole 20 amp air handler feeds
Valuation:
$1,500
Permit #:
ELEC-22-1189
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Relocate/replace electrical disconnect reconnect existing 2 pole 30 amp condenser feed to newly installed condenser
Valuation:
$1,500
Permit #:
56005
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-replace existing firemotic cover plate to basement furnace -replace existing whip/disconnect to condenser. reconnect newly installed 2 pole 30 amp
Valuation:
$1,200
Permit #:
54605
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Upgrade existing electric panel in basement install outlet and switches (inside) outside outlet upgrades
Valuation:
$5,000
Permit #:
56745
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-installation of a 2 pole 40 amp mini split condenser feed and service outlet
Valuation:
$1,500
Permit #:
84460
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-installation of a 2 pole 20 amp mini split condenser feed w service outlet
Valuation:
$1,500
Permit #:
84459
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-installation of a 2 pole 40 amp mini split condenser feed and service outlet
Valuation:
$1,500
Permit #:
24-1560
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
-install a new 2 pole 45 amp mini split condenser feed and service outlet
Valuation:
$1,500
Permit #:
84092
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
License # GC-37175
Providence, RI
106
BZ Score
$23.7K
Avg Project
-
Projects
License # B-012148
Providence, RI
111
BZ Score
$600
Avg Project
-
Projects
License # A-004183
Providence, RI
108
BZ Score
$16K
Avg Project
-
Projects
Raymond D Melanson Electric and Safety Reviews
BuildZoom hasn't received any reviews for Raymond D Melanson Electric and Safety. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Raymond D Melanson Electric and Safety License info
License Not Verified
| Status | Active |
- BuildZoom has not yet reviewed this license for verification.
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are Raymond D Melanson Electric and Safety, click “This is My Business” to update your information.
82
Permits
- Building permit records show that Raymond D Melanson Electric and Safety has worked on 82 permitted projects.