Home business;;
Valuation:
$50
Permit #:
24-187
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Converting to natural gas furnace nan
Valuation:
$7,800
Permit #:
MECH204561
Status:
issued
Fee:
$127
Permit Type:
N/A
Building Type:
N/A
Security system 8-cameras-2-keypads 3-motion sensors 2-monitor entry system 12-elec sttikes 9-card reader 6-keypad 7-door contact 2-push exit button 2-sinern 3-touch screen etc. as per nec 2008 east district
Valuation:
N/A
Permit #:
591616
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Retail-8 new 8 channel lights at exterior, 6- 120v gas furnace, 6- new 250 w m.h at exterior, 4-exits, 6-30amp 1 phase air conditioning. condensors, 6-recepts, 5 -switches, replace existing 200 amp 3 phase panel w/new, replace existing 200 amp 1 phase panel w/new as per 2008 nec (north district)
Valuation:
N/A
Permit #:
375982
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire alarm: 1 facp 2 remote annuciators 12 duct detectors 2 n.a.c. power supplies 3 smoke detectors 4 heat detectors 1 flow tamper 23 pull stations 44 horn strobes 1 ansul module as per nfpa-72 )(cc dist)
Valuation:
N/A
Permit #:
197750
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Dental office fit out new outlets, fixtures, switches and panel changes (2) per 2008 nec (dental office)
Valuation:
N/A
Permit #:
508505
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
600 amp service, 6 position meteing, wiring for dentist office, gift shop, proffesional office and 2 dwelling units, fire alarm system, all wiring as per 2008 nec nfpa-72
Valuation:
N/A
Permit #:
326046
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
100 amp overhead temporary service (90 days) with (2) 20 amp gfci outlets for new building construction as per 2008 nec (south dist)
Valuation:
N/A
Permit #:
294232
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Dental fit out 20-switches 47-outlets 35-lights as per 2008 nec (office bldg)
Valuation:
N/A
Permit #:
419608
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 25 phone and data points cat 5 riser rated cable pvc jacket 4 pair twisted 160 longest run as per 2005 nec (south district)
Valuation:
N/A
Permit #:
212246
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Tenant fit out as per 2008 nec lighting outlets exits etc existing service to remain (north dist)
Valuation:
N/A
Permit #:
292865
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove exisitng 200amp service feeding 3 apartments install new 250amp service with house meter/panel as per 2005 nec (cc district)
Valuation:
N/A
Permit #:
211982
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install 300a service proper grounding 3 gang meter socket 2 150a mcb panels 1 100a mcb panel & rewire duplex as per 2005 nec
Valuation:
N/A
Permit #:
170067
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install fire alarm system as per 2008 nec and nfpa72 (commercial)
Valuation:
N/A
Permit #:
397452
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New home 150amp service, wiring for branch circuts 7kw dryer 7 kw hw heater 7 kw air conditioning 3kw photovoltaic 9 kw range
Valuation:
N/A
Permit #:
275257
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New home 150 amp service , wiring for branch circuts 7kw dryer 7 kw hw heater 7 kw air conditioning 3kw photovoltaic 9 kw dryer
Valuation:
N/A
Permit #:
275259
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New construction: single family dwelling 100 amp service outlets lights as per 2005 nec (east dist)
Valuation:
N/A
Permit #:
189962
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New construction: single family dwelling 100 amp service outlets lights as per 2005 nec (east dist)
Valuation:
N/A
Permit #:
189961
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New 2 bedroom row home complete wiring and install 100amp service as per 2005 nec (east district)
Valuation:
N/A
Permit #:
226409
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New 2 bedroom row home complete wiring and install 100amp service as per 2005 nec (east district)
Valuation:
N/A
Permit #:
226408
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
HIC # 053629
Philadelphia, PA
131
BZ Score
$8.5K
Avg Project
-
Projects
130
BZ Score
$2.2K
Avg Project
-
Projects
149
BZ Score
$10K
Avg Project
-
Projects
Rhoads Electric Reviews
BuildZoom hasn't received any reviews for Rhoads Electric. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Rhoads Electric License info
License Not Verified
| HIC # | PA041036 |
| Status | Active |
| State | Pennsylvania |
- When BuildZoom last verified this license, it had an expiration date of July, 2025. Check the current license status of Rhoads Electric with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| HIC # | PA108829 |
| Status | Active |
| State | Pennsylvania |
- When BuildZoom last verified this license, it had an expiration date of May, 2026. Check the current license status of Rhoads Electric with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| HIC # | PA108829 |
| Status | Active |
| State | Pennsylvania |
| Type | Electrical Contracting |
- When BuildZoom last verified this license, it had an expiration date of July, 2017. Check the current license status of Rhoads Electric with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| HIC # | PA041036 |
| Status | Active |
| State | Pennsylvania |
| Type | Residential/Commercial Electrician, Bucket Truck Service. Residential/Commercial Air Conditioning. |
- When BuildZoom last verified this license, it had an expiration date of July, 2017. Check the current license status of Rhoads Electric with the Pennsylvania Office of the Attorney General
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | PA093372 |
| Status | Inactive |
| State | Pennsylvania |
- According to the Pennsylvania Office of the Attorney General, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Rhoads Electric at the Pennsylvania Office of the Attorney General.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| HIC # | PA093372 |
| Status | Inactive |
| State | Pennsylvania |
| Type | Residential And Commercial Electrical Service. Specializing In The Rewiring Of Old Homes. |
- According to the Pennsylvania Office of the Attorney General, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Rhoads Electric at the Pennsylvania Office of the Attorney General.
This is a sample of licensing data; click here to access a complete history.
93
BuildZoom Score
Insured
| Insurer | State Farm |
| Insured up to | $1,000,000 |
22
Permits
- Building permit records show that Rhoads Electric has worked on 22 permitted projects.
Rhoads Electric Employees
JR
Joseph R. Rhoads
Owner
RR
Robert H. Rhoads
President
SR
Steven P. Rhoads
Owner