Updated: Dec 10, 2025
Location and Projects
Address
Fowlerville, MI, 48836
Use our bidding system to
request a quote
Rosalez Joshua Michael Electrician
Their BuildZoom score of 0 does not rank in the top 50% of Michigan contractors.
If you are thinking of hiring Rosalez Joshua Michael, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Rosalez Joshua Michael Contact Information
Phone Number: (734) 210-7667
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Building Permits by Rosalez Joshua Michael
This is a sample of this contractor's permits. Click here to access their complete permit history.
- swap out 2 prong outlets to 3 prong addition gfci protection - addition ceiling fan light - addition ducting for exhaust fan bathroom - addition smoke detectors
Valuation:
N/A
Permit #:
ELECR25-0686
Status:
expired
Fee:
$50
Permit Type:
N/A
Building Type:
N/A
Complete upgrade of electrical service ( outside ) adding 5 panels to inside - four for each apartment and 1 for common areas. swapping out all plugs and switches in each apartment adding 2 x circuits to laundry adding 8 circuits ( 2 per apartment )
Valuation:
N/A
Permit #:
ELECC24-0500
Status:
final
Fee:
$510
Permit Type:
N/A
Building Type:
N/A
During covid renovation occured without permits. the electrical company that did the work did not obtain permit. we have been called in to prepare complex for inspection and to make sure all work passes inspection. this was previously applied for under residential permit elecr24-1266 and $425.00 paid towards the permit. this was cancelled due to a commercial property
Valuation:
N/A
Permit #:
ELECC24-0475
Status:
final
Fee:
$175
Permit Type:
N/A
Building Type:
N/A
*permit cancelled by contractor* renovation and electrical was conducted by another electrician without permit. we have been asked to completed electrical and bring to code. we attended same and ran new circuit for laundry dryer and range in kitchen. work was completed with wafer lights receptacles switch's being swapped out
Valuation:
N/A
Permit #:
ELECR24-0917
Status:
withdrawn
Fee:
$104
Permit Type:
N/A
Building Type:
N/A
Swapped out 100 amp meter to 200 amp meter bonding grounding disconnect added circuit to garage for 100 amp sub panel ( trench ) added new circuit for hot water added new circuit for air conditioning unit added sleeves for future solar
Valuation:
N/A
Permit #:
ELECR24-2565
Status:
final
Fee:
$215
Permit Type:
N/A
Building Type:
N/A
Added a subpanel from house to detached garage trenched to garage. added subpanel to garage and wired up garage for 50 amp circuit
Valuation:
N/A
Permit #:
ELECR25-0332
Status:
final
Fee:
$144
Permit Type:
N/A
Building Type:
N/A
Swap panel to 200 amp panel relocated panel location to meet code addition disconnect surge protector grounding and bonding to code
Valuation:
N/A
Permit #:
ELECR25-0216
Status:
final
Fee:
$130
Permit Type:
N/A
Building Type:
N/A
- installed gfci over kitchen sink for disposal - installed a gfci in 1st floor bathroom - installed a gfci in 2nd floor bathroom - installed a gfci protect outlet under toilet in 2nd floor bathroom coming off a new outlet next to sink ( both gfci protected
Valuation:
N/A
Permit #:
ELECR23-3160
Status:
expired
Fee:
$17
Permit Type:
N/A
Building Type:
N/A
Replace knob and tube wiring to the existing portions of the property (updated 9.9)
Valuation:
$0
Permit #:
ELECR25-2337
Status:
final
Fee:
$140
Permit Type:
N/A
Building Type:
N/A
*void as wrong workclass commercial property* previous remodel work completed without permit. we have been called in to get property to code and inspected - 3 units - remodel included kitchen and bathroom and service
Valuation:
N/A
Permit #:
ELECR24-1266
Status:
voided
Fee:
$425
Permit Type:
N/A
Building Type:
N/A
Panel upgrade 100 to 200 amps full knob and tube replenishment ( rewire )
Valuation:
N/A
Permit #:
ELECR25-0926
Status:
triage
Fee:
$303
Permit Type:
N/A
Building Type:
N/A
Upgrade panel to 200 amp underground panel - move to location to meet code
Valuation:
N/A
Permit #:
ELECR25-0217
Status:
expired
Fee:
$60
Permit Type:
N/A
Building Type:
N/A
Permit cancelled by contractor via email on 10/19/22 (tim lambert) owner is no longer working with then- owner purchases this house and several renovations have been conducted without permit. looking for guidance from inspector as to how to proceed
Valuation:
N/A
Permit #:
ELECR22-2738
Status:
expired
Fee:
$15
Permit Type:
N/A
Building Type:
N/A
2 fans have been installed in the past with no permit. we have been engaged to check the work and bring to code and obtain a permit for this work
Valuation:
N/A
Permit #:
ELECR23-1132
Status:
final
Fee:
$30
Permit Type:
N/A
Building Type:
N/A
Installed second meter can for ev charger - installed 60 amp ev circuit - circuit for interlock kit and outlet 200 amp - grounding and bonding to code
Valuation:
N/A
Permit #:
ELECR24-3588
Status:
expired
Fee:
$90
Permit Type:
N/A
Building Type:
N/A
Electrical to 2 ceiling fans installed by unknown electrician - we have been engaged to check and correct any issues and then obtain a permit
Valuation:
N/A
Permit #:
ELECR23-1131
Status:
final
Fee:
$30
Permit Type:
N/A
Building Type:
N/A
Panel swap out smoke detectors added rewire for kitchen layout ( new ) rewire hot water circuit in basement rewire washer and dryer circuit
Valuation:
N/A
Permit #:
ELECR24-0862
Status:
issued
Fee:
$134
Permit Type:
N/A
Building Type:
N/A
Swap out panel to 200 amp underground addition 100 amp subpanel in garage - includes trench to garage addition 50 amp ev charger to garage addition dedicated line for air conditioning split systems and disconnect
Valuation:
N/A
Permit #:
ELECR22-2707
Status:
final
Fee:
$187
Permit Type:
N/A
Building Type:
N/A
Added hardwired smokes circuit rewired front porch lights refed baseboard plugs bedrooms living room and dining room hallway light
Valuation:
N/A
Permit #:
ELECR24-2564
Status:
final
Fee:
$97
Permit Type:
N/A
Building Type:
N/A
Upgrade 200 amp panel - moved addition a 100 amp subpanel in garage - underground trench to garage bonding and grounding to code added a 50 amp ev charger in garage
Valuation:
N/A
Permit #:
ELECR23-3652
Status:
final
Fee:
$147
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
116
BZ Score
-
Avg Project
-
Projects
License # 2102206965
Auburn Hills, MI
120
BZ Score
$180K
Avg Project
-
Projects
125
BZ Score
$2.7K
Avg Project
-
Projects
Rosalez Joshua Michael Reviews
BuildZoom hasn't received any reviews for Rosalez Joshua Michael. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Rosalez Joshua Michael License info
License Not Verified
| License # | 6219340 |
| Status | Active |
| State | Michigan |
| Type | Electrical |
- When BuildZoom last verified this license, it had an expiration date of December, 2025. Check the current license status of Rosalez Joshua Michael with the Michigan Department of Licensing & Regulatory Affairs
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | 6219340 |
| Status | Active |
| State | Michigan |
| Type | Electrical |
- When BuildZoom last verified this license, it had an expiration date of December, 2025. Check the current license status of Rosalez Joshua Michael with the Michigan Department of Licensing & Regulatory Affairs
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | LIC-200274 |
| Status | Inactive |
| City | Ann Arbor |
| Type | Contractor |
- According to the The City of Ann Arbor, MI, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Rosalez Joshua Michael at the The City of Ann Arbor, MI.
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are Rosalez Joshua Michael, click “This is My Business” to update your information.
95
Permits
- Building permit records show that Rosalez Joshua Michael has worked on 95 permitted projects.