Orr Protection Systems Electrician

Orr Protection Systems, 16 Technology Dr, Irvine, CA (Employees: Clark Orr, Clark Orr Jr, and Clark Orr) holds a Electrical, Fire Protection license and 1 other license according to the California license board.

Their BuildZoom score of 109 ranks in the top 5% of 336,931 California licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Orr Protection Systems, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Orr Protection Systems Services

Start a project today:

Orr Protection Systems Contact Information

Phone: (502) 244-4500 Edit
Headquarters Address: 2100 NELSON MILLER PARKWAY, Louisville, KY, 40223
Local Address: 16 TECHNOLOGY DRIVE SUITE 134, Irvine, CA 92618 Edit

Orr Protection Systems Irvine

Quality

109
95th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Orr Protection Systems has a BuildZoom score of 109, which places them above 95% of 336,931 contractors in California.

Activity

11 projects
2025
11 projects
2024
14 projects
2023
Our building permit records indicate that Orr Protection Systems has worked on at least 36.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

6 projects
Commercial Renovations
3 projects
Home Additions
11 projects
Electrical projects
Analyzing permits over the last 4 years shows that Orr Protection Systems mostly works on electrical project and commercial renovation projects.

Pricing

2 projects
$5k-$20k
5 projects
$20k-$50k
5 projects
$50k-$100k
1 project
$100k-$250k
2 projects
$1mil+
Value Not Public: 18.0 projects
The typical size of their permits is approximately $55,000. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Orr Protection Systems

Sort by: Notable Notable | Date Date | Job Value Job Value
Fire permit - fire alarm
2023-11-29
Initiating devices: 0 - relocate existing notification devices on the 1st floor. we will rewire new circuits and tie them into the existing power supply. existing fire alarm system to remain as is in a functional state. notification devices: 17. sh
Valuation:
$2,708,309
Permit #:
FR-2023-288272
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Initiating devices: 0 - relocate existing notification devices on the 1st floor. we will rewire new circuits and tie them into the existing power supply. existing fire alarm system to remain as is in a functional state. notification devices: 14. sh
Valuation:
$4,028,637
Permit #:
FR-2023-288271
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Due to the tenant improvements in this building and the addition of hvac units; we will replace the existing sprinkler monitoring panel with an addressable notifier nfs-320 fire control panel. replace the existing fire alarm control panel and fire alarm remote annunciator at the main entrance along with the smoke detector and manual pull station. addition monitor modules to all sprink... see more
Valuation:
$87,000
Permit #:
FAP2024-00280
Status:
issued
Fee:
$1,347
Permit Type:
N/A
Building Type:
N/A
Fire sprinklers
2024-11-13
Replace existing clean agent cylinders and pipe in switch room with new cylinders and pipe filled with fluoro-k agent · existing photoelectric smoke detectors manual stations aborts to remain as is in a functional state · existing av devices are to remain as is · reuse existing conduit and wiring where applicable · orr protection shall provide one room integrity test for the protected... see more
Valuation:
N/A
Permit #:
BLD2024-02701
Status:
final
Fee:
$427
Permit Type:
N/A
Building Type:
N/A
6/f:upgrade spot type detection to air sampling.other f/a sys features to remain same. remove the smoke (e) smoke detectors conduit & wire.provide/install 2(n) air sampling detectors & pipe.provide/install d sampling multi zone power supply.provide/install new monitor modules.rev f/a panel program
Valuation:
$87,589
Permit #:
202411064504
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
10 - office
Due to the tenant improvements in this building and the addition of hvac units; we will replace the existing sprinkler monitoring panel with an addressable notifier nfs-320 fire control panel. replace the existing fire alarm control panel and fire alarm remote annunciator at the main entrance along with the smoke detector and manual pull station. we will addition monitor modules to al... see more
Valuation:
$95,483
Permit #:
FAP2024-00038
Status:
final
Fee:
$1,513
Permit Type:
N/A
Building Type:
N/A
Replac (e) pre-action detection controls & fire alarm system. replace (e) panel w (n) notifier nfs-320. all (e) initiating devices will be replaced one for one. reuse all (e) wire & conduit. all (e) notification devices will remain as is. orr to perform a full functional test prior to final inspect
Valuation:
$110,300
Permit #:
202308154494
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
10 - office
Commercial electrical permit
2022-12-08
· install (7) new vesda duct detectors w/power supplies · install (2) vesda detectors for return air grilles w/power supplies · install (2) vesda detectors for the hot and cold aisles w/power supplies · remove existing vesda piping and detectors on existing crac units after new system is installed fm-200 system - server room · relocate (2) nozzles on west wall for new ceiling height ·... see more
Valuation:
$205,000
Permit #:
COM-ELC-21-034
Status:
complete
Fee:
$84
Permit Type:
Alteration
Building Type:
N/A
Building permit application
2023-01-18
Fire alarm permit: pier 39 lp"; provide and install nac booster power supply notification appliances smoke detector control relay and monitor modules for tenant improvement. at 2nd & 3rd floors and roof level pier 39 building n
Valuation:
$9,886
Permit #:
B-2019-0320
Status:
complete
Fee:
$616
Permit Type:
N/A
Building Type:
Vacant restaurant
Due to the tenant improvements in this building and the replacement of hvac units; we will replace the existing conventional duct detectors with new conventional duct detectors. existing global hvac shutdown will remain as is. existing sprinkler monitoring system will remain existing in a functional state. prior to the inspection with the ahj orr protection systems inc. shall perform ... see more
Valuation:
$44,786
Permit #:
FAP2024-00045
Status:
issued
Fee:
$574
Permit Type:
N/A
Building Type:
N/A
Neotech is performing tenant improvement on their fremont ca facility. as a result the existing fire alarm notification system needs to be modified to accommodate the improvements. the fire alarm scope of work is as follows: provide and install five (5) new ceiling mount horn/strobes to be connected to the spare nac circuit on existing fire-lite facp. fire alarm system is existing and... see more
Valuation:
$21,648
Permit #:
FAP2025-00012
Status:
issued
Fee:
$628
Permit Type:
N/A
Building Type:
N/A
Fire alarm system
2023-09-02
(s15) 23-alm-01 due to the bad network card on the existing fire alarm panel (facp2) we will have to replace the node 5 orp switchgear 2 facp. we will replace the panel with a new kidde aries. all the existing field devices (initiating and notification) are compatible and shall remain existing as is. no other modifications will be required. all existing circuits shall be connected to ... see more
Valuation:
N/A
Permit #:
FPFAS2300004
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire sprinklers
2023-07-24
Fire suppression system - replace existing chemetron micro 1-ev panel with new kidde aries mlx panel. · remove existing notirifer rp-1002 panel. devices to be tied into new kidde aries mlx panel. · upgrade existing photoelectric smoke detectors. replace one for one. reuse existing wiring. · upgrade existing manual release and fire pull stations. · provide one (1) new manual release st... see more
Valuation:
N/A
Permit #:
BLD2023-01879
Status:
final
Fee:
$423
Permit Type:
N/A
Building Type:
N/A
Plumbing
2025-04-17
Unit #n-111-1 humble sea taproom; install and alteration to the existing automatic fire sprinkler system
Valuation:
N/A
Permit #:
PP20250320204
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Plumbing
2025-03-19
Unit# n-111-1 humble sea taproom: install and alteration to the existing automatic fire sprinkler system
Valuation:
N/A
Permit #:
PP20250319167
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Due to an emergency we will have to replace the existing fire-lite ms9600udls with a new fire-lite es200x. all the existing initiating devices are compatible with the new facp. all the existing field devices (nac & initiating) will remain existing as is. all the existing conduit and wire will remain existing as is. orr to perform a full functional test prior to final inspection
Valuation:
N/A
Permit #:
EW202212097730
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire permit - fire alarm
2022-09-20
Building e - 3rd floor; furnish and install one ceiling mounted horn strobe in video studio room 301. building f - 1st floor; furnish and install one ceiling mounted horn strobe in machine room 108. furnish and install one ceiling mounted horn strobe in rf lab room 101. furnish and install two duct detectors with remote test switches and control relays for two new air conditioning uni... see more
Valuation:
N/A
Permit #:
FR-2022-283539
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Due to emergency/panel replacement of (e) firelite ms9600udls with a new firelite es200x. all (e) field devices to remain will perform functional tesst prior to schedule inspection
Valuation:
$20,040
Permit #:
202301200464
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
10 - office
Electrical service upgrade
2022-12-16
· replace existing chemetron micro 1-ev panel with new kidde aries mlx panel · remove existing notirifer rp-1002 panel. devices to be tied into new kidde aries mlx panel upgrade existing photoelectric smoke detectors. replace one for one. reuse existing wiring upgrade existing manual release and fire pull stations · provide one (1) new manual release station · upgrade existing abort s... see more
Valuation:
N/A
Permit #:
BLD2021-03156
Status:
canceled
Fee:
$422
Permit Type:
N/A
Building Type:
N/A
Halon fire suppression & pre-action detection and controls u
Valuation:
$29,468
Permit #:
FIRE2023-0055
Status:
final
Fee:
$1,372
Permit Type:
Fire alarm commer...
Building Type:
N/A

Similar Contractors See more

License # 778366
132
BZ Score
$17K
Avg Project
-
Projects
License # 1014827
134
BZ Score
$350
Avg Project
-
Projects
License # 997486
132
BZ Score
$5.8K
Avg Project
-
Projects

Orr Protection Systems Reviews

BuildZoom hasn't received any reviews for Orr Protection Systems. Click here to be alerted when reviews are posted about them.
Please write a review about Orr Protection Systems
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.