Updated: Apr 04, 2025
Location and Projects
Headquarters Address
Elgin, IL, 60173
Local address
Phoenix, AZ, 85007
Use our bidding system to
request a quote
Sac Wireless LLC
Sac Wireless LLC, (Employees: Brian Petersen, Christopher Thomas Bondurant, and Gregory Paul Hutton) holds a General Commercial license and 2 other licenses according to the Arizona license board.
Their BuildZoom score of 104 ranks in the top 9% of 71,576 Arizona licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Sac Wireless LLC, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Sac Wireless LLC Services
Start a project today:
Sac Wireless LLC Contact Information
Phone Number: (312) 895-4977
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Sac Wireless LLC
Quality
104
91st percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Sac Wireless LLC has a BuildZoom score of 104, which places them above 91% of 71,576 contractors in Arizona.
Activity
|
2 projects
|
2025 |
|
3 projects
|
2024 |
|
14 projects
|
2023 |
Our building permit records indicate that Sac Wireless LLC has worked on at least
19.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Pricing
|
1 project
|
$5k-$20k |
|
2 projects
|
$20k-$50k |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Modification to existing cell tower. remove 3 antenna. replace 3 antenna. replace 6 rrh. install 3 rrh. replace surge supressor. relocate 3 tma. install trunk cable. replace fiber cable. changes to equipment enclosure: remove/replace power plant. install new breakers. remove/replace batteries
Valuation:
$65,000
Permit #:
PMT20-12461
Status:
final
Fee:
$936
Permit Type:
Macro cell site
Building Type:
N/A
Modification to existing tower: tower scope of work: · remove (6) antennas · remove (5) rrhs · remove (1) covp · remove (1) hybrid cable · install (3) antennas · install (3) rrhs · install (2) breakout pendants · install (2) hybrid cables (1-1/2") · paint antennas to match existing ground scope of work: · remove (2) equipment cabinets · remove (1) junction box · remove (1) esmb · remo... see more
Valuation:
$30,000
Permit #:
PMT21-13439
Status:
final
Fee:
$572
Permit Type:
Macro cell site
Building Type:
N/A
Tower work: remove (6) antennas remove (9) rrhs remove (1) junction box remove (3) combiners remove (3) hybrid cable (1-1/4") remove (1) hybrid cable (5/8") remove (1) power cable (7/8") install (6) antennas install (6) antennas install (6) rrhs install (2) breakout pendants install (2) hybrid cables (1-1/2") install (6) 96 pipe mounts ground work: remove (2) equipment cabinets remove... see more
Valuation:
N/A
Permit #:
T21CM05217
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Tower work: remove (3) antennas remove (6) rrhs remove (1) covp remove (1) existing hybrid relocate (6) antennas relocate (3) rrhs install (3) antennas install (3) rrhs install (2) breakout pendants install (2) hybrid (1-1/2") ground work: removed (2) generic cabinets relocate (1) esmb relocate (1) fsmf relocate (1) asia relocate (1) asik relocate (3) abias relocate (1) abil relocate ... see more
Valuation:
N/A
Permit #:
T21CM05207
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Remove (9) antennas; remove (3) tma's; remove (1) covp; install (6) antennas; install (6) rru's; install (2) breakout pendants; install (2) hcs 2.0 trunk cables; install (9) jumpers; remove (2) cabinets; remove (5) rru's; remove (1) covp; install (1) delta hpl3 600 amp dc cabinet; install (1) delta lb3 battery cabinet; install (2) hcs 2.0 junction boxes
Valuation:
N/A
Permit #:
T21CM03522
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
This project will be comprised of: changes on the existing at&t; antenna array: · remove (1) existing antenna per sector (3) sectors (3) total · relocate (1) existing antenna per sector (from position 2 to position 1) (3) sectors (3)total · replace (1) existing antenna per sector (3) sectors (3) total · relocate (1) existing rrh unit per sector (from position 2 to position 1) (3) sec... see more
Valuation:
N/A
Permit #:
T21OT00006
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
X435 at&t first responder project this project will be comprised of: changes on the existing at&t antenna array: · replace (1) existing antenna per sector (3) sectors (3) total · remove (1) existing antennas and pipe mounts per sector (3) sectors (3) total · relocate (1) existing tma antenna per sector (3) sectors (3) total · replace (2) existing at&t rrh units per sector (3) sectors ... see more
Valuation:
N/A
Permit #:
B202013159
Status:
final
Fee:
$1,612
Permit Type:
N/A
Building Type:
N/A
This project (p265) is located at the intel campus (4500 s dobson rd) and will consist of reducing the total # of antennas from 9 to 6 replacing the remaining antennas and associated ancillary equipment within at&t's lease area the outward visual appearance will remain basically the same the existing lease area will not expand extension req 7/15/21 permit extended to 1/11/2021
Valuation:
$45,000
Permit #:
BLD21-0171
Status:
complete
Fee:
$884
Permit Type:
N/A
Building Type:
N/A
Changes on the existing monopalm: remove (1) antenna per sector; (3) sectors (3) total. replace (1) antenna per sector; (3) sectors (3) total. remove (1) rrh per sector. replace (2) rrh per sector. changes in the existing at&t equipment enclosure area: replace existing indoor power plant with new vertiv netsure -48vdc power system. adm20-00458
Valuation:
$40,000
Permit #:
PMT20-12705
Status:
final
Fee:
$676
Permit Type:
Macro cell site
Building Type:
N/A
This project will be comprised of: changes on the existing at&t antenna array: · replace (1) existing antenna per sector (3) sectors (3) total · remove (1) existing tmas unit per sector (3) sectors (3) total · relocated (1) existing tmas unit per sector (3) sectors (3) total from position (1) to popsition (2) · remove (2) existing rrh unit per sector (3) sectors (6) total · install (2... see more
Valuation:
$50,000
Permit #:
BLD20-2075
Status:
complete
Fee:
$958
Permit Type:
N/A
Building Type:
N/A
Modification to existing tower • removing a 16” diameter canister and replacing with a 30” stealth canister. • increasing the compound block wall enclosure height from 5’-4’ to the same existing height of the generator enclosure 8’-0” to conceal ground mounted equipment
Valuation:
$50,000
Permit #:
PMT19-07075
Status:
final
Fee:
$780
Permit Type:
Macro cell site
Building Type:
N/A
Remove (7) antennas and (3) tma's and (6) rrh's relocate (1) antenna install (3) new antennas and (6) rrh's 65-ft centerline remove various equipment and install new equipment within existing enclosure at&t
Valuation:
N/A
Permit #:
B202007412
Status:
final
Fee:
$2,670
Permit Type:
N/A
Building Type:
N/A
This at&t; antenna modification project is needed for first responder network authority (www.firstnet.gov ) and consist of removing and replacing antennas and associated ancillary equipment the height of the tower and existing lease area will remain the same
Valuation:
N/A
Permit #:
T20CM08971
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
T-mobile scope of work · the removal of (3) existing antennas · the removal of (10) existing radios · the removal of (3) existing equipment cabinets · the removal of (2) existing covp's on ground · the removal of (2) covp's on tower · the removal of (1) existing equipment mount · the removal of (1) existing ppc cabinet · the removal of (2) existing high-cap hybrid cables · the capping... see more
Valuation:
N/A
Permit #:
B202011947
Status:
approved
Fee:
$1,240
Permit Type:
N/A
Building Type:
N/A
At&t tower remove 6 antenna install 3 antenna. remove 3 tma. remove 6 rrh install 6 rrh/remove 6 lines of coax/ground: remove/replace power plant/remove 2 battery cabinets/install 1 battery cabinet/install automatic transfer switch/install 2 purcel cabinets/install one new dc12 and ancillary breaker equipment
Valuation:
N/A
Permit #:
B202006228
Status:
final
Fee:
$1,716
Permit Type:
N/A
Building Type:
N/A
Remove 3 panel antennas and install 3 new antennas remove 3 rru's install 1 top hat on existing cabinet remove ppc cabinet and replace with new ppc cabinet install new airscale bbu inside existing cabinet install new 9712 equipment cabinet install 1 fiber junction box new conduit 3 new multimode fiber jumpers 9 new fiber jumper cables new hybrib cable new h-frame sprint
Valuation:
N/A
Permit #:
B201810786
Status:
final
Fee:
$2,278
Permit Type:
N/A
Building Type:
N/A
Adding one (1) small 9” tall x 6” wide filter behind an existing antenna the filter and bracket only weighs 20 pounds. the height of the tower and existing lease area will remain the same
Valuation:
$5,000
Permit #:
PMT20-11825
Status:
final
Fee:
$229
Permit Type:
Macro cell site
Building Type:
N/A
Remove (3) antennas remove (3) rrh install (3) new antennas install (3) new rrh 67-ft centerline remove (1) aplha cabinet install (1) new dc power plant and (1) battery cabinet within existing equipment compound associated work t-mobile
Valuation:
N/A
Permit #:
B202008367
Status:
expired
Fee:
$1,207
Permit Type:
N/A
Building Type:
N/A
Super expedited - remove (3) radios and swap (3) existing antennas with (3) new antennas and associated cabling. install equipment expansions to the top of existing cabinets (approx 1'-2') with associated electrical wiring
Valuation:
$26,000
Permit #:
PMT19-08406
Status:
final
Fee:
$1,591
Permit Type:
Other commercial
Building Type:
N/A
Changes on the existing at&t antenna array: · remove (1) existing antenna per sector (3) sectors (3) total · replace (1) antenna per sector (3) sectors (3) total · install (2) new tma units per sector (3) sectors (6) total changes in the existing at&t equipment enclosure area: · install (2) new rrh units per sector (3) sectors (6) total · install (6) new twin triplexers · reconnect (1... see more
Valuation:
$35,000
Permit #:
BLD20-3010
Status:
complete
Fee:
$735
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
License # 281683
Tempe, AZ
109
BZ Score
$30K
Avg Project
-
Projects
License # 340857
Scottsdale, AZ
105
BZ Score
$25K
Avg Project
-
Projects
License # ROC 334693
Mesa, AZ
106
BZ Score
-
Avg Project
-
Projects
Sac Wireless LLC Reviews
BuildZoom hasn't received any reviews for Sac Wireless LLC. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Verified License
BuildZoom confirmed this contractor's license
Sac Wireless LLC License info
Verified License
| License # | 269379 |
| Status | Active |
| State | Arizona |
| Type | General Commercial |
- BuildZoom has not verified this license since November, 2024.
Verify this license's status for Sac Wireless LLC at the Arizona Registrar of Contractors.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | 245688 |
| Status | Active |
| State | Arizona |
- When BuildZoom last verified this license, it had an expiration date of December, 2021. Check the current license status of Sac Wireless LLC with the Arizona Registrar of Contractors
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | 330194 |
| Status | Inactive |
| State | Arizona |
| Type | Specialty Commercial |
- According to the Arizona Registrar of Contractors, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Sac Wireless LLC at the Arizona Registrar of Contractors.
This is a sample of licensing data; click here to access a complete history.
104
BuildZoom Score
688
Permits
- Building permit records show that Sac Wireless LLC has worked on 688 permitted projects.
Sac Wireless LLC Employees
BP
Brian Petersen
Qualifying Party
CB
Christopher Thomas Bondurant
Chief Executive Officer President
GH
Gregory Paul Hutton
Former Qp/None
JK
Jonathan Wade Mc Kinley
Manager
JS
Joseph Pasquale Sanzo
Member
NC
Nokia Of America Corporation
Subsidiary
NL
Nokia Solutions & Networks Us Llc
Member
RS
Robert James Strauch
Member
SB
Shawna Brown
Qualifying Party
SB
Shawna Lynn Brown
Qp
WK
William Raymon Koziel
Member