Updated: Nov 19, 2025
Location and Projects
Address
9 Mayfield Rd, Auburn, MA, 01501
Use our bidding system to
request a quote
Skip HVAC
Their BuildZoom score of 98 ranks in the top 16% of 139,240 Massachusetts licensed contractors.
If you are thinking of hiring Skip HVAC, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Skip HVAC Contact Information
Phone Number: (508) 340-7235
Edit
Address: 9 Mayfield Rd, Auburn, MA 01501
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Skip HVAC Auburn
Quality
98
84th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Skip HVAC has a BuildZoom score of 98, which places them above 84% of 139,240 contractors in Massachusetts.
Activity
|
9 projects
|
2025 |
|
10 projects
|
2024 |
Our building permit records indicate that Skip HVAC has worked on at least
19.0 projects over the past 2 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
18 projects
|
HVAC projects |
Analyzing permits over the last 4 years shows that Skip HVAC mostly works on
hvac project
projects.
Pricing
|
1 project
|
$5k-$20k |
|
1 project
|
$50k-$100k |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Installation of new two-zone hvac system install a new bryant furnace with a 2-ton coil in the basement including a safety switch and drain pan. install a 2-ton bryant condenser. design and install basement ductwork for optimal airflow. install honeywell 2-zone motorized dampers with a control board. provide supply and return vents per manual j load calculations. ensure compliance wit... see more
Valuation:
N/A
Permit #:
SM-2025-006
Status:
issued
Fee:
$225
Permit Type:
N/A
Building Type:
N/A
Installation of new heating and air conditioning system (single zone ) - install a new bryant furnace in the basement complete with a 2.5-ton coil mounted on top. - install new bryant condenser ductwork installation: - design and install ductwork running through the basement ensuring optimal airflow and efficient system performance. - each room will be equipped with supply vents and r... see more
Valuation:
N/A
Permit #:
SM-2025-005
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Duplex unit #2 install a new gas furnace with matching evaporator coil in the basement. set the new air conditioning condenser unit outdoors on a proper stand/pad. design and install complete ductwork system sized and laid out according to acca manual j d and s standards to ensure proper airflow comfort and efficiency
Valuation:
N/A
Permit #:
SM-2025-020
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Duplex unit #2 install a new gas furnace with matching evaporator coil in the basement. set the new air conditioning condenser unit outdoors on a proper stand/pad. design and install complete ductwork system sized and laid out according to acca manual j d and s standards to ensure proper airflow comfort and efficiency
Valuation:
N/A
Permit #:
SM-2025-019
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Install new central air system bryant gas furnace paired with legacy bryant air conditioning condenser all supply vents and registers will be carefully sized and placed according to the manual j (load calculation) manual d (duct design) and manual s (equipment selection) standards
Valuation:
N/A
Permit #:
SM-2025-015
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Installation of new two-zone heating and air conditioning system install a new 96% high-efficiency bryant gas furnace in the basement. mount a 3-ton bryant evaporator coil on top of the furnace. provide and install a safety float switch and a drain pan beneath the coil for added protection against water damage. install a new 3-ton bryant air conditioning condenser to complete the system
Valuation:
N/A
Permit #:
SM-2025-014
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Install new central air system bryant gas furnace paired with legacy bryant air conditioning condenser all supply vents and registers will be carefully sized and placed according to the manual j (load calculation) manual d (duct design) and manual s (equipment selection) standards
Valuation:
N/A
Permit #:
SM-2025-013
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Install new central air system bryant gas furnace paired with legacy bryant air conditioning condenser all supply vents and registers will be carefully sized and placed according to the manual j (load calculation) manual d (duct design) and manual s (equipment selection) standards
Valuation:
N/A
Permit #:
SM-2024-024
Status:
issued
Fee:
$225
Permit Type:
N/A
Building Type:
N/A
Install new central air system bryant gas furnace paired with legacy bryant air conditioning condenser all supply vents and registers will be carefully sized and placed according to the manual j (load calculation) manual d (duct design) and manual s (equipment selection) standards
Valuation:
N/A
Permit #:
SM-2024-023
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Install new central air system (heat pump only) equipment to be installed: 1x mitsubishi suz-ka24nahz outdoor hyper heat pump 1x mitsubishi svz-kp24na indoor multi-position ducted air handler installation details: air handler installation: the indoor air handler will be installed in the attic. it will be securely positioned within a drain pan and a safety switch will be installed bene... see more
Valuation:
$19,400
Permit #:
SH-24-0412
Status:
issued
Fee:
$233
Permit Type:
N/A
Building Type:
N/A
Install a new central air system as per industry best practices and standards. the gas furnace will be mounted in the basement and will be equipped with a coil on the top and a safety float switch underneath for added safety. the installation of ductwork and vents will be done in accordance with manual j d and s specifications. to ensure optimal performance all equipment will be insta... see more
Valuation:
N/A
Permit #:
SM-2024-022
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Install a new central air system as per industry best practices and standards. the gas furnace will be mounted in the basement and will be equipped with a coil on the top and a safety float switch underneath for added safety. the installation of ductwork and vents will be done in accordance with manual j d and s specifications. to ensure optimal performance all equipment will be insta... see more
Valuation:
N/A
Permit #:
SM-2024-021
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Lot #12 installation of new heating and air conditioning system ( two zone system) - install a new bryant furnace in the basement complete with a 3-ton coil mounted on top. - include a safety switch and a drain pan underneath the coil to ensure safe and efficient operation. - install new bryant condenser 3t
Valuation:
N/A
Permit #:
SM-2024-016
Status:
issued
Fee:
$225
Permit Type:
N/A
Building Type:
N/A
Lot #10 installation of new heating and air conditioning system (two zone system) - install a new bryant furnace in the basement complete with a 2-ton coil mounted on top. - include a safety switch and a drain pan underneath the coil to ensure safe and efficient operation. - design and install ductwork running through the basement ensuring optimal airflow and efficient system performa... see more
Valuation:
N/A
Permit #:
SM-2024-017
Status:
issued
Fee:
$225
Permit Type:
N/A
Building Type:
N/A
Lot # 11 install a new central air (two zones system) gas furnace bryant along with a bryant legacy outdoor condenser. each room is equipped with a dedicated supply air and return air
Valuation:
N/A
Permit #:
SM-2024-015
Status:
issued
Fee:
$225
Permit Type:
N/A
Building Type:
N/A
To install gas furnace 96% efficiency 60, 000 btu's in the basement w/ac coil and all new ductwork sealed and insulate 2 zone. one zone for the 1st floor and the other zone for the finished basement. air conditioning condenser to be mount outside by the bulk head door. 2.5 ton goodman 14 seer 410a
Valuation:
N/A
Permit #:
SM-2021-009
Status:
issued
Fee:
$125
Permit Type:
N/A
Building Type:
N/A
Install gas furnace in basement with coil; 2 zone system. 1st fl floor vents and return 2nd fl bring duct up to the attic for 2nd fl bents on the ceiling. air conditioning condenser mount on the plastic pad in the back of house
Valuation:
$15,000
Permit #:
21080319
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
To install gas furnaces one in the basement 3 zone and one in the attic single zone for the 2nd floor all new ductwork sealed and insulate per code. 2 air conditioning condenser 14 seer 410a on per floor
Valuation:
N/A
Permit #:
21-4SM
Status:
expired
Fee:
$270
Permit Type:
N/A
Building Type:
N/A
To install 2 gas furnaces in the mechanical room in the basement w coils and 2 condenser for cooling stretch duct through the floor to the retail store above drop ceiling all the registers will be 2x2 feet on the drop ceiling
Valuation:
$63,600
Permit #:
M-20-0003
Status:
issued
Fee:
$55
Permit Type:
Renovation
Building Type:
Commercialother
Install new central air system (heating and cooling) gas furnace will be installed in the basement unfinished area
Valuation:
N/A
Permit #:
SM-2024-011
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
License # 26373
Peabody, MA
122
BZ Score
$1.8K
Avg Project
-
Projects
130
BZ Score
$2.4K
Avg Project
-
Projects
License # CS-118861
Holliston, MA
116
BZ Score
$6.2K
Avg Project
-
Projects
Skip HVAC Reviews
BuildZoom hasn't received any reviews for Skip HVAC. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Hiring a contractor?
Skip HVAC License info
License Not Verified
| License # | 9853 |
| Status | Active |
| City | Newton |
| Type | Sheetmetal Contractor |
- When BuildZoom last verified this license, it had an expiration date of December, 2022. Check the current license status of Skip HVAC with the City of Newton Massachusetts
This is a sample of licensing data; click here to access a complete history.
98
BuildZoom Score
39
Permits
- Building permit records show that Skip HVAC has worked on 39 permitted projects.
Skip HVAC Employees
DM
Derek R Morang
Owner