Sol-tek Industries Inc at 827 JEFFERSON AVE, Clovis, CA 93612, held a Solar Contractor license (#911489) with the California contractors license board with an expiration date of 02-28-2030. We last verified the license was inactive on 02-13-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
Install 6.4kw roof mount photovoltaic system w (16) modules with optimizers a 7.6kw inverter monitoring system and a 40a photovoltaic breaker @ single family residence. it is connected to the existing 200a main service panel/200a main service breaker. roof photovoltaic solar system
Install 7.30 kw roof mount photovoltaic system w (20) modules with optimizers a 7.6 kw inverter a 100 a load center and a 80a photovoltaic breaker @ single family residence. it is connected to the new 200a main service panel/200a main service breaker
Install 4.8kw roof mount photovoltaic system w (12) modules with optimizers a 5kw inverter monitoring system and a 30a photovoltaic breaker @ single family residence. it is connected to the existing 200a main service panel/200a main service breaker
Install 8kw roof mount photovoltaic system w (20) modules with optimizers a 7.6kw inverter monitoring system and a 40a photovoltaic breaker @ single family residence. it is connected to the new 125a main service panel/100a main service breaker. roof photovoltaic solar system - 8.000 kw/dc - 20 panels - 20 optimizers - 1 air conditioning disconnect - 100a main panel swap (like for like... see more
Install 7.2kw roof mount photovoltaic system w (18) modules with optimizers a 3.8kw inverter monitoring system and a 20a photovoltaic breaker @ single family residence. it is connected to the existing 200a main service panel/100a main service breaker. new sub panel for existing loads also on permit
Installation of 2.555kw roof mount photovoltaic system w (7) modules with micro-inverters a 125a combiner panel monitoring system a 13.5kwh ess a backup gateway a 100a subpanel and a 40a photovoltaic breaker @ single family residence. connect to the existing 200a msp/200a msb. (2) existing photovoltaic systems on home
Install 11.6kw roof mount photovoltaic system w (29) modules with optimizers a 7.6kw inverter monitoring system and a 40a photovoltaic breaker @ single family residence. it is connected to the existing 200a main service panel/200a main service breaker
Er - installation of an 11.600dc kw roof mounted solar system consisting of 29 solar modules 29 solar optimizers 1 solar inverter 1 combiner sub panel 1 air conditioning disconnect and 2 solar batteries 40a photovoltaic breaker
Res- ground mount pm (16.40) kw with (40) modules (2) 100 amp main panels (2) solar edge inverters ground mount photovoltaic solar - 16.400 kw/dc - 40 axitec ac-410mh/144s - 40 solaredge p485 - 2 solaredge se7600h-us - tie-in line side tap - 100a fussed air conditioning disconnect - swap out main service panel like for like revised 9.14.22
Electrical permit for main panel swap. it's a like-for-like panel swap. we're replacing the existing 200a main service panel with a new siemens mc2442b1200efv which has a 200a main breaker and a 225a buss
Electrical permit for main panel swap. it's a like-for-like panel swap. we're replacing the existing 200a main service panel with a new siemens mc2442b1200efv which has a 200a main breaker and a 225a buss
Roof photovoltaic solar system - 10.400 kw/dc - 26 panels - 26 microinverters - 1 combiner panel - 1 enphase combiner box - 1 air conditioning disconnect - tie-in will be a line-side tap new 225 amp panel
Electrical permit application for a like-for-like panel swap. we need to change out the existing 200a main service panel for a new square d sc3042m200pf with a 200a main breaker and a 225a buss
Installation of an 11.600dc kw roof mounted solar system consisting of 29 solar modules 29 solar optimizers 1 solar inverter 1 combiner sub panel 1 air conditioning disconnect and 2 solar batteries
We need to swap the main service panel. the new panel will be a siemens mc2442s1200sc and the tie will be a 80a/2p breaker at the line-side breaker slot. the fused air conditioning disconnect will no longer be needed. everything else will remain the same
Install 7.92kw roof mount photovoltaic system w (22) modules with optimizers a 7.6kw inverter monitoring system and a 40a photovoltaic breaker @ single family residence. it is connected to the existing 200a main service panel/200a main service breaker
Install 6.8kw roof mount photovoltaic system w (17) modules with optimizers a 6kw inverter monitoring system and a 40a photovoltaic breaker @ single family residence. connected to existing 200a msp/200a msb. roof photovoltaic solar system - 6.800 kw/dc - 17 solaria powerxt-400r-pm - 17 p400 - 1 se6000h-us - inverter will go next to the msp - tie-in with a 40a/2p breaker in (e) msp
Single family residence roof photovoltaic solar system- 6.800 kw/dc - 17 solaria powerxt-400r-pm - 17 p400 optimizers - 1 solaredge se7600h-us inverter - 1 60a non-fused air conditioning disconnect - tie-in will be with a 40a/2p breaker in existing main service panel
Roof photovoltaic solar system - 10.400 kw/dc - 26 panels - 26 microinverters - 1 combiner panel - 1 enphase combiner box - 1 air conditioning disconnect - tie-in will be a line-side tap
Install 7.20 kw roof mount photovoltaic system w (18) modules with optimizers a 7.6 kw inverter and a 40a photovoltaic breaker @ single family residence. it is connected to the existing 200a main service panel/200a main service breaker
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Sol-tek Industries Inc at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.