Location and Projects

Address
PO BOX 370-378, Montara, CA, 94037
Use our bidding system to request a quote

Stefanick Construction Electrician

Stefanick Construction, Montara, Po Box 370, Montara, CA (Employee: Shad Justin Stefanick) holds a Electrical license and 1 other license according to the California license board.

Their BuildZoom score of 95 ranks in the top 22% of 336,931 California licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Stefanick Construction, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Stefanick Construction Services

Start a project today:

Stefanick Construction Contact Information

Phone: (415) 816-3152 Edit
Address: PO BOX 370-378, Montara, CA 94037 Edit

Building Permits by Stefanick Construction

Sort by: Notable Notable | Date Date | Job Value Job Value
Addition 40 amp 240v circuit to behind range from sub panel using 6/3 romex with ground. run is below floor in crawl space. addition 20 amp 120v arc circuit to hall closet from sub panel using romex below floor in crawl space
Valuation:
N/A
Permit #:
EW202412193133
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-23
Unit 943. install install lighted mirrors to bathroom. pull new circuit from existing light circuit at the switch to wall behind mirrors. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202408190559
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-23
Unit 420. install lighted mirrors in each bathroom. pull new circuit from existing light circuit at the switch to wall behind mirrors. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202408150506
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-23
Unit 2711. install lighted mirrors in each bathroom. pull new circuit from existing light circuit at the switch to wall behind mirrors. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202408150505
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-05
Unit 2607. install lighted mirrors in bathrooms. pull new circuit from existing light circuit at the switch to wall behind mirrors. addition new gfci/arc fault breakers and occupancy sensors per nec code
Valuation:
N/A
Permit #:
EW202408010219
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-23
Unit 805. install lighted mirrors to bathroom. pull new circuit from existing light circuit at the switch to wall behind mirrors. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202408190560
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-23
Unit 1037. install lighted mirrors to bathroom. pull new circuit from existing light circuit at the switch to wall behind mirrors. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202408190558
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-02
Unit 1429. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407280150
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-02
Unit 1127. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407280148
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-26
Unit 1729. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407230075
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-26
Unit 801. install lighted mirrors in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407230069
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-25
Unit 1930: install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407179935
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-25
Unit 1603: install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407179934
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-17
Unit 1023. install lighted mirror to bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407109800
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-17
Unit 1041. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407109799
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-17
Unit 2226. install lighted mirrors in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407109798
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-07-17
Unit 2327. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407109797
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-02
Unit 602. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407290158
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-01
Unit 326. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407280146
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical
2024-08-01
Unit 910. install lighted mirror in bathroom. pull new circuit from existing light circuit at the switch to wall behind mirror. addition new gfci/arc fault breaker and occupancy sensor per nec code
Valuation:
N/A
Permit #:
EW202407230077
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 1038922
142
BZ Score
$3.2K
Avg Project
-
Projects
License # 971231
143
BZ Score
$22.5K
Avg Project
-
Projects
License # 1088154
140
BZ Score
$999
Avg Project
-
Projects

Stefanick Construction Reviews

BuildZoom hasn't received any reviews for Stefanick Construction. Click here to be alerted when reviews are posted about them.
Please write a review about Stefanick Construction
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.