Teampcs Inc, 3947 Landmark St, Culver City, CA (Employees: Alvin L Tate, Charles Bryon Freedman, and Jennings Holdings Llc) holds a Electrical license and 3 other licenses according to the California license board.
Their BuildZoom score of 115 ranks in the top 2% of 336,931 California licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Teampcs Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
[eplan] pc for installation of pv2. system size is 50.4 kwdc (40 kwac & 45.24 kwcec-ac) using (120) qp 420 modules and (4) fronius symo 10.0-3 central inverters. connected to existing 400 amp service panel
[eplan] plan check for lost set of approved plans scope of work is a pv2 system system size is 18kwac system includes 67 modules with opimzers and two central inverters. partial permit fees paid for under 21041-20000-02166
$0 permit fee due to sb1222 and ab1414 pv2. install 43.74 kw dc/39.85 kw air conditioning cec roof mounted photovoltaic system with (108) photovoltaic modules and (3) solaredge inverters (se10000h-us) and (1) solaredge inverter (se7600h-us) and a panel
$0 permit fee due to sb1222 and ab1414 pv2 plan cehck for new roof photovoltaic system. system size is 64.8 kw dc/58.7 kw air conditioning cec. scope of work consists of (160) photovoltaic modules with optimizers (1) 33.3 kw inverter (1) 20 kw inverter (1) sub panel and a 75 kva transformer
Supplemental permit to permit # 21041-30000-59159. to add: install 40 ev car chargers on 1 new load center. install 1 gateway circuit (39. 3kva to 5 kva circuits and 1 5kva to 20 kva circuits)
$0 fee per ab1414 plan check for photovoltaic roof mounted system feed in tariff(fit) photovoltaic system size: 496.8kw dc 450.32kw air conditioning cec with 1242 photovoltaic modules and 10 inverters(33.3kw) connected service: 800a 480 3phase
Supplemental to permit #21041-30000-21800 to addition install 8 ev car chargers on 2 new load centers no fee dept error. install (8) 3.1 thru 5 hp-kva and (2) 0 to 200amp sub panels
Pv2. installation of 42.93 kw dc roof mounted photovoltaic system. (106) modules and (4) inverters (3 @ 10 kw and 1 @ 7.6 kw ratings). $0 permit fee per state assembly bill ab 1414
Install (39) 3.1 thru 5 and (1) 5.1 thru 20 hp-kva (2) 0 to 200amp sub panels and (1) new circuit (install 40 ev car chargers on 2 new load center install 1 gateway circuit)
Down grade fusible electrical section mb1 feeding unit meters to match the electrical pull rating of dwp pull section in order to install 23* car chargers on msa electrical section. install 23* car chargers on 2* 100 amp load centers with 2* load management circuits
Plan check for a pv2 roof-mounted photovoltaic system. system is feed-in tariff. system size is 908 kw dc 823.72 kw ac-cec and consists of (24) inverters (6) load centers and (2, 270) modules. $0 permit fee per state senate bill sb 1222 and state assembly bill ab 1414
Revision to approved set of plans. reduction in system size - permit work description revised to: pv2. install 57.96 kw dc 51.38 kw cec-ac roof mounted grid tied photovoltaic system. (168) modules with (4) 10 kw rated string inverters (((plan check for a pv2 roof-mounted photovoltaic system. system size is 71.76 kwdc/63.61 kwac-cec and consists of (5) 12 kwac rated inverters (1) load... see more
**zero dollar permit fee per ab-1414 sb-1222** plan check for photovoltaic roof mounted and carports system feed in tariff (fit). 4 new photovoltaic carports and photovoltaic mount on existing aircaft hangers. system size: 1049.42 kw air conditioning cec 992.5 kw air conditioning 1296.48 kw dc with 3552 photovoltaic modules and (25) 33.3 kw inverter and (8) 20 kw inverters b#18010-3... see more
Supplemental permit to permit #21041-30000-05198 ladwp wr#2189870 - per dwp request downsize breaker for mb2 from 600a to 400a to comply with not overloading the pull section
Supplemental permit to permit #21041-90000-24696 ladwp wr#2189113 - per dwp request downsize main msa fuse from 1600 a to 1200 a to comply with not overloading the pull section
Supplemental permit to permit #21041-90000-25712 ladwp wr #2191850 - per dwp request downgrade mb1 breaker from 1600a to 1200a to comply with not overloading the pull section
BuildZoom verified this license was active as of June 2026.
Verify this license's status for Teampcs Inc at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
License #
1015744
Status
Active
State
California
Business Type
Corporation, Ltd Liability
When BuildZoom last verified this license, it had an expiration date of July, 2022. Check the current license status of Teampcs Inc with the California Contractors State License Board
This is a sample of licensing data; click here to access a complete history.
Inactive License
License #
1015744
Status
Inactive
State
California
Type
General Building
Business Type
Corporation, Ltd Liability
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Teampcs Inc at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.
Inactive License
License #
741578
Status
Inactive
State
California
Type
Electrical
Business Type
Corporation, Ltd Liability
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Teampcs Inc at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.