×

We'll help you find the right contractor.

Share your project details and we'll reach out to toby's Heating and Air so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >
t

Location and Projects

Address
Greenville, NC, 00000
Use our bidding system to request a quote

toby's Heating and Air

toby's Heating and Air at Greenville, NC 00000, has a BuildZoom score of 0 and ranks in the top 99% of 101,103 North Carolina contractors.

If you are thinking of hiring toby's Heating and Air, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

toby's Heating and Air Services

Start a project today:

toby's Heating and Air Contact Information

toby's Heating and Air Greenville

Quality

Alert*
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
*No active license on file. If you are toby's Heating and Air, click “This is My Business” to update your information.

Activity

28 projects
2025
22 projects
2024
4 projects
2023
Our building permit records indicate that toby's Heating and Air has worked on at least 54.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

51 projects
HVAC projects
46 projects
Mechanical projects
Analyzing permits over the last 4 years shows that toby's Heating and Air mostly works on hvac project and mechanical project projects.

Pricing

7 projects
< $5k
1 project
$5k-$20k
Value Not Public: 50.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by toby's Heating and Air

Sort by: Notable Notable | Date Date | Job Value Job Value
Mechanical sub permit new install
2025-06-20
Renovate the kitchen dining room and bathrooms at this property. -relocate 2 existing supply duct runs in bathrooms. -relocate 1 existing supply duct run in kitchen. -installing new 4 round metal dryer vent duct for new location of dryer. routing new dryer duct up to attic for roof penetration due to laundry room being on poured cement floor in middle of home
Valuation:
N/A
Permit #:
MCSP-2025-0514
Status:
complete
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Utility reconnect gas
2025-04-14
Gas meter locked out due to breached under ground gas line. existing gas line and service is to small to serve existing appliances. contacted guc 4/11/25 to convert to 2psi after performing pressure test on existing 7/8acr copper gas line under slab of home to mechanical room with 180kbtu tankless water heater and 100kbtu gas furnace. run 1/2 black iron pipe above ground routed along ... see more
Valuation:
N/A
Permit #:
UTIL-REC-2025-0049
Status:
issued
Fee:
$75
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-05-12
Replacement of upstairs 2ton split system heat/pump with 14.3seer2 2ton split system heat/pump. reuse existing supply ductwork. replace accessible return ductwork for direct access to new indoor unit with new work platform/catwalk
Valuation:
N/A
Permit #:
MECH-2025-0504
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-02-28
Replace existing 1.5ton split system heat/pump and all accessible return and supply ductwork. installation of 15.2seer2 1.5ton split system heat/pump with new supply trunk line and flex ducts. replace existing return flex duct
Valuation:
N/A
Permit #:
MECH-2025-0193
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-04-21
Replacement of 3.5ton 10seer gas/electric package unit serving downstairs to 4ton 16seer 2stage cooling/2stage heating gas/electric package unit. reuse existing supply and return duct. reuse use existing gas line
Valuation:
N/A
Permit #:
MECH-2025-0395
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical sub permit new install
2025-09-25
Construct 14 x 16 pool house with 1 bathroom. -installation of 12k btu 25.6seer2 high wall ductless mini split. -install indoor cassette on exterior wall. -route line set/control wire/drain line down exterior wall in slim duct. -set outdoor unit on pad
Valuation:
N/A
Permit #:
MCSP-2025-0904
Status:
complete
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-01-27
Replacement of existing 2.5ton single stage gas/electric package unit to 3ton 16seer 2stage cooling/heating gas/electric package unit. enlarge/replace existing return flex duct to existing return stack
Valuation:
N/A
Permit #:
MECH-2025-0086
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-02-10
Replacement of 2ton electric heat/cool only split system to 15.6seer2 2ton split system heat/pump. enlarge/modify return ductwork and install filter grills. reuse existing supply ductwork
Valuation:
N/A
Permit #:
MECH-2025-0129
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-10-06
Replacement of 1.5ton split system heat/pump serving bonus room. existing indoor unit location is in knee wall. relocating new indoor unit to hanging in garage below knee wall. transition supply and return into existing ductwork
Valuation:
N/A
Permit #:
MECH-2025-1424
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2024-11-25
Replacement of 3ton split system heat/pump serving upstairs with 15.8seer2 3ton split system heat/pump. reusing existing supply ductwork and return flex ducts serving bedrooms. running new 16 return flex duct to capture and enlarge existing 8 flex ducts serving common areas to 10 and 12
Valuation:
N/A
Permit #:
MECH-2024-1558
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2024-10-31
Replacement of 80% 80k btu input gas furnace w 3ton conventional split system. installing 80% 80k btu 2stage gas furnace w 14.3seer2 3ton conventional split system. reuse existing supply and return ductwork. reuse existing bvent flue pipe and gas line
Valuation:
N/A
Permit #:
MECH-2024-1494
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2024-10-22
Replacement of existing 2ton split system heat/pump w 2ton 15.6seer2 split system heat/pump. running new liquid line through existing wall chase. installing new return plenum to indoor unit and enlarging main return flex duct from 10 to 12. reuse existing supply ductwork
Valuation:
N/A
Permit #:
MECH-2024-1457
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical sub permit new install
2025-02-21
Finishing upstairs bedroom with hvac electrical insulation for additional room. adding (2) 6 supply ducts and (1) 8"-12x12 return off existing ductwork serving upstairs to new addition upstairs. existing system is 3ton split system heat/pump with total load of 29500btu adding a additional 3800btu's to total load
Valuation:
N/A
Permit #:
MCSP-2024-0450
Status:
linked
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2024-04-15
Replacing 2ton heat/pump package unit with gas/electric package unit. run 20’ coated 1/2copper gas line under home from 2psi gas meter to regulator then adapting to iron for package unit connection. made contact with guc to confirm meter is adequate for additional 70k btu to existing service. adding 7” supply diffuser in floor in living room. home does not have a supply in the living ... see more
Valuation:
N/A
Permit #:
MECH-2023-0209
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-08-06
Replacement of existing 2.5ton split system heat/pump serving upstairs with 3ton 19seer2 multi stage inverter split system heat/pump. reuse existing supply with return duct modifications
Valuation:
N/A
Permit #:
MECH-2025-1134
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-02-26
Replacement of existing 2ton split system heat/pump w 2ton 14.3seer2 split system heat/pump. reuse existing supply and return ductwork
Valuation:
N/A
Permit #:
MECH-2025-0180
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Residential mechanical- changeout
2025-05-24
Replacement of existing 2ton split system heat/pump with 2ton 17seer2 split system heat/pump. enlarge existing return duct starter and reuse existing supply ductwork
Valuation:
$14,200
Permit #:
MECR2025-000068
Status:
complete
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2024-09-04
Replacement of 1.5ton split system heat/pump serving upstairs of home. installing 1.5ton 15.2seer2 split system heat/pump. replacing existing 12 return flex serving unit to 14 flex. reuse existing supply ductwork
Valuation:
N/A
Permit #:
MECH-2024-1255
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2024-09-13
Replacement of 2ton counter flow split system heat pump serving downstairs. installing 15.6seer2 2ton counter flow split system heat pump with new line set. reuse existing supply ductwork. common air return
Valuation:
N/A
Permit #:
MECH-2024-1296
Status:
issued
Fee:
$135
Permit Type:
N/A
Building Type:
N/A
Mechanical replacement
2025-01-16
Replacement of 2.5ton split system heat pump to 2.5ton 15.4seer2 split system heat pump. reusing existing supply ductwork and return stack. installing new return starter plenum with new 14 flex to existing return stack. adding 12x12x8"flex return to master bedroom
Valuation:
N/A
Permit #:
MECH-2023-1417
Status:
expired
Fee:
$135
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 14359
111
BZ Score
-
Avg Project
-
Projects
License # SP.PH.38952
110
BZ Score
$7.2K
Avg Project
-
Projects
License # SP.PH.27442
110
BZ Score
$6.4K
Avg Project
-
Projects

toby's Heating and Air Reviews

BuildZoom hasn't received any reviews for toby's Heating and Air. Click here to be alerted when reviews are posted about them.
Please write a review about toby's Heating and Air
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.