We'll help you find the right contractor.

Share your project details and we'll reach out to Turner Air & Heat so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

T

Location and Projects

Address
680 Karen Dr, Titusville, FL, 32780
Use our bidding system to request a quote

Turner Air & Heat HVAC/Mechanical Contractor

Turner Air & Heat, 680 Karen Dr, Titusville, FL (Owned by: Jeffrey Turner) holds a Contractor license and 4 other licenses according to the Daytona Beach license board.

Their BuildZoom score of 108 ranks in the top 5% of 191,428 Florida licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Turner Air & Heat, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Turner Air & Heat Services

Start a project today:

Turner Air & Heat Contact Information

Phone: (321) 289-0266
Address: 680 Karen Dr, Titusville, FL 32780

Turner Air & Heat Titusville

Quality

108
95th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Turner Air & Heat has a BuildZoom score of 108, which places them above 95% of 191,428 contractors in Florida.

Activity

1 project
2025
7 projects
2024
2 projects
2023
Our building permit records indicate that Turner Air & Heat has worked on at least 10.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

3 projects
New Constructions
9 projects
HVAC projects
3 projects
Mechanical projects
Analyzing permits over the last 4 years shows that Turner Air & Heat mostly works on hvac project and mechanical project projects.

Pricing

2 projects
$5k-$20k
1 project
$50k-$100k
4 projects
$250k-$500k
Value Not Public: 1.0 project
The typical size of their permits is approximately $175,130. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Turner Air & Heat

Sort by: Notable Notable | Date Date | Job Value Job Value
Residence hvac-mechanical
2025-06-26
Install new 5 ton r54b freon 14.3 seer2 gas furnace system titan armor flex inside and out hurricane tie downs locking caps seal plenum ss2 float switch gas t sediment trap draft hood connector wifi thermostat. permit
Valuation:
$8,250
Permit #:
25BC12356
Status:
issued
Fee:
$140
Permit Type:
N/A
Building Type:
N/A
Residence hvac-mechanical
2024-08-01
Install new 3.5 ton 14.3 seer2 grandaire straight cool system removal & disposal of existing equipment. ss2 float switch titan amoflex rubber isolator pads locking caps hurricane tie downs 10-kw heat with breaker flush copper & drain line. new filter dryer inside permit
Valuation:
$7,000
Permit #:
24BC14767
Status:
final
Fee:
$134
Permit Type:
N/A
Building Type:
N/A
Mechanical permit
2023-01-25
Change letter received to remove the range hood from the permit. 02-20-23 br install ductwork new r6 flex duct strap up & seal all ductwork. run exhaust fan venting to soffit. run range vent to soffit. seal air handler deck. supply & return plenum. run new dryer vent. forced return. 16 drops. h&c white grills install new 3.5 ton 16 seer tempstar straight cool system 10kw heat w/b (60 ... see more
Valuation:
N/A
Permit #:
H23000703
Status:
complete
Fee:
$182
Permit Type:
Residential
Building Type:
New construction
Residence hvac-mechanical
2022-07-27
Install new 4 ton 14 seer grandaire straight cool system in the attic. removal & disposal of existing equipment. remove air handler from the attic. put a new air handler back in the attic. install new auxiliary drain pan under air handler. ss3 float switch. ss2 float switch. 5kw heat. flush copper & drain line. condenser pad. locking caps. hurricane tie-downs. seal plenum and return. ... see more
Valuation:
$9,800
Permit #:
22BC10625
Status:
final
Fee:
$143
Permit Type:
N/A
Building Type:
N/A
Residence hvac-mechanical
2022-01-21
Install customer's mini split install indoor head run copper and drain lines install line set cover pressure check system pull a vacuum on system check system charge **does not include electrical work!** requires 208/230v 15amp double pole breaker. disconnect on outdoor unit
Valuation:
$950
Permit #:
21BC25833
Status:
final
Fee:
$114
Permit Type:
N/A
Building Type:
N/A
Residence single family residence addition
2024-03-12
Building executive suite with rv port
Valuation:
$295,000
Permit #:
23BC00948
Status:
final
Fee:
$1,404
Permit Type:
N/A
Building Type:
N/A
Residence sfr-duplex new
2024-07-19
Construct new single family residence
Valuation:
$300,000
Permit #:
24BC14043
Status:
issued
Fee:
$12,538
Permit Type:
N/A
Building Type:
N/A
Residence sfr-duplex new
2024-04-17
Building single family home
Valuation:
$295,000
Permit #:
22BC22577
Status:
final
Fee:
$12,667
Permit Type:
N/A
Building Type:
N/A
Residence single family residence renovation
2024-01-11
Full home remodel including roof and siding
Valuation:
$250,259
Permit #:
23BC06711
Status:
final
Fee:
$1,115
Permit Type:
N/A
Building Type:
N/A
Commercial renovation
2024-11-26
Renovation of interior from doughnut shop to ice cream shop
Valuation:
$100,000
Permit #:
24BC22019
Status:
final
Fee:
$1,698
Permit Type:
N/A
Building Type:
N/A
Residence hvac-mechanical
2021-09-21
Install new 2 ton 14 seer tempstar straight cool system removal & disposal of existing equipment. 5kw heat. air handler stand. flush copper. honeywell t4 thermostat. 2 - 20"x20 return stamp grilles. hurricane tie-downs. locking caps. permit. filter box with filter. new supply plenum. ss2 float switch. 1-year labor warranty. 10-year manufacture parts warranty
Valuation:
$3,900
Permit #:
21BC19914
Status:
expired
Fee:
$124
Permit Type:
N/A
Building Type:
N/A
Residence hvac-mechanical
2021-08-23
Install new 3 ton 14 seer tempstar straight cool system 10kw heat. new thermostat. new copper with titan armoflex. drain line & condensate pump condenser pad. hurricane tie-downs. ss2 float switch. 1-year labor warranty. 10-year manufacture warranty
Valuation:
$4,700
Permit #:
21BC17948
Status:
final
Fee:
$127
Permit Type:
N/A
Building Type:
N/A
Residential new permit - ex: new house
2022-06-06
Single family residence
Valuation:
$250,000
Permit #:
BR-2018-1533
Status:
final
Fee:
$10,059
Permit Type:
N/A
Building Type:
N/A
Residential new permit - ex: new house
2022-04-22
Single family residence
Valuation:
$250,000
Permit #:
BR-2018-1593
Status:
final
Fee:
$10,709
Permit Type:
N/A
Building Type:
N/A
Residential new permit - ex: new house
2022-06-06
Single family residence
Valuation:
$250,000
Permit #:
BR-2018-1592
Status:
final
Fee:
$10,274
Permit Type:
N/A
Building Type:
N/A
Commercial miscellaneous
2024-07-12
Room addition
Valuation:
$78,720
Permit #:
24BC13595
Status:
triage
Fee:
$35
Permit Type:
N/A
Building Type:
N/A
Residence hvac-mechanical
2021-02-19
Install new 2.5 ton 14 seer grandaire heat pump package unit
Valuation:
$5,085
Permit #:
21BC03274
Status:
final
Fee:
$130
Permit Type:
N/A
Building Type:
N/A
Commercial renovation
2024-07-12
Room addition
Valuation:
$78,720
Permit #:
24BC12934
Status:
withdrawn
Fee:
$35
Permit Type:
N/A
Building Type:
N/A
Residence sfr-duplex new
2023-01-16
Building executive suite and rv port
Valuation:
$295,000
Permit #:
23BC00814
Status:
withdrawn
Fee:
$35
Permit Type:
N/A
Building Type:
N/A

Turner Air & Heat Reviews

BuildZoom hasn't received any reviews for Turner Air & Heat. Click here to be alerted when reviews are posted about them.
Please write a review about Turner Air & Heat
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.