Share your project details and we'll reach out to
Tvc Improvements
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Tvc Improvements at 1422 Farnam St, Davenport, IA 52803, held a General Contractor license (#C102381) with the Iowa contractors license board. We last verified the license was inactive on 01-20-2010.
Their BuildZoom score is 93 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 39,764 Iowa contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Tear off and reroof house only cover roof with 22 square of asphalt shingles. remove all layers of existing roofing material. 2 layers max. of shingles 1 layer of buildup- ice shield required by code
Tear off and reroof house only cover roof with 20 square of asphalt shingles. remove all layers of existing roofing material. 2 layers max. of shingles 1 layer of buildup- ice shield required by code
Per report and design by iowa pe 22444 remove and replace a portion of the foundation wall. repair floor joists and replace sill plate as directed by engineer. engineer report for compliance of work completed before inspection
Cover roof with 27 square of asphalt shingles. remove all layers of existing roofing material. 2 layers max. of shingles 1 layer of buildup- ice shield required by code
In rear of home construct 12 x 14 house addition and 24 x 24 garage addition. full frost free conventional foundation with crawl space and garage floor slab on grade. conventional framing eng. trusses. conditioned crawl space with access. 11 x 11 deck. smoke and carbon monoxide detection required throughout existing house. other trades require separate permits. all per city code
Tear off and reroof house and garage cover roof with 35 square of asphalt shingles. remove all layers of existing roofing material. 2 layers max. of shingles 1 layer of buildup- ice shield required by code
Garage as well. repalce soffit and fascia. replacing aluminum with vnyl cover sides of building with 24 square of vinyl siding. metal siding requires ground contact. vapor and water resistive barrier required per chapter 7 of the irc and/or chapter 14 of the ibc. all per city code
Replace existing 12'8 x 19'6 covered deck floor only. (5)24x42 and (1)12x42 ftgs supporting double 2x10 beams. 2x8 joists hangered to beams will support the floor. beams to be pocketed over foundation. stairs to grade. 12 x 42 post footings required by code- must be inspected before concrete is poured. all per city code. 2015 ibc/irc
Fire repair damage in hallway. sistering 2x4 studs on either side of the hallway common non-bearing walls. replacing 4 of 2x4 top cap. electrical work. other trades require separate permits. smoke and carbon monoxide detectors required per code. all per city code
Tear off and reroof house cover roof with 16 square of asphalt shingles. remove all layers of existing roofing material. 2 layers max. of shingles 1 layer of buildup- ice shield required by code
Fill in small basement window. 2x6 joists supported by a 2x8 house mounted ledger and 2x8 beam on new posts and footings. stairs to grade. 12 x 42 post footings required by code- must be inspected before concrete is poured. all per city code. 2015 ibc/irc
Remove and replace wood stoops on the front of the building. 2x8 joists 16 on center supported by building mounted ledgers and 2x8 beams. side deck on 12"x42 piers front deck on 24"x42 piers to support deck and roof(existing). connections to resist uplift. stairs to grade. 3 rises from deck to grade. 12 x 42 post footings required by code- must be inspected before concrete is poured. ... see more
Replace soffit/fascia and gutters. install 8 replacement windows in existing jambs. windows in hazardous locations require safety glazing. existing egress windows shall not be reduced in size unless if it is more that the required egress size. this permit requires a passing final inspection. all per city code. 2015 irc/ibc
Remove and replace perimeter foundation wall and footing of house per code level floor and repair/replace beams per engineered drawings by p.e. david valliere #22444. remove and replace drywall in livingroom. other trades require separate permits. smoke and carbon monoxide detectors required per code. all per city code
Remove and reconstuct porch floor on 6th street side. 2x8 joists and double 2x8 beams on new posts. new posts to support porch roof. no change to roof structure. 12 x 42 post footings required by code- must be inspected before concrete is poured. all per city code. 2015 ibc/irc
Tear off. cover roof with 24 square of asphalt shingles. remove all layers of existing roofing material. 2 layers max. of shingles 1 layer of buildup- ice shield required by code
Tear off. cover roof with 24 square of asphalt shingles. remove all layers of existing roofing material. 2 layers max. of shingles 1 layer of buildup- ice shield required by code
Building 2-3x3landings and 3 sets of steps outside of entry doors in front and side of home. 12x42 piers. 4x4 post. guard rails installed to code. building 2 landings at bottom of steps to 3x3 dimension. all per city code
Cover sides of building with 18 square of vinyl siding. metal siding requires ground contact. vapor and water resistive barrier required per chapter 7 of the irc and/or chapter 14 of the ibc. all per city code
Construct a 14'x30 garage addition to attached garage. property line marked at footing inspection to confirm 5 side yard setback. sheetrock common wall of house and garage. 12x42 trench footing for entire bearing perimeter of addition. maintain 6 foundation exposure and 6 of fall in 10 from garage for final grade. hard surface drive from overhead door to street required. provide attic... see more
According to the Iowa Workforce Development Agency, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Tvc Improvements at the Iowa Workforce Development Agency.
This is a sample of licensing data; click here to access a complete history.