×

We'll help you find the right contractor.

Share your project details and we'll reach out to Vilar Construction so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
V

Location and Projects

Address
135 Mckean St, Philadelphia, PA, 19148
Use our bidding system to request a quote

Vilar Construction

Their BuildZoom score of 93 ranks in the top 27% of 125,106 Pennsylvania licensed contractors.

If you are thinking of hiring Vilar Construction, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Vilar Construction Contact Information

Phone: (610) 659-3938
Address: 135 Mckean St, Philadelphia, PA 19148

Building Permits by Vilar Construction

Sort by: Notable Notable | Date Date | Job Value Job Value
Alteration permit
2019-09-20
Total interior renovation/remodeling of an existing structure (details as shown on the plan) seperate permits required for trade jobs
Valuation:
N/A
Permit #:
1000157
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2017-06-19
Ez permit standard alterations - for alterations to an existing one family dwelling as per attached standard. deviations from this standard will result in permit revocation and require submission of construction plans. replace brick fence wall 3 high in front of building 14 wide cap existing brick walls with stone capping. rebuild existing steps of front steps with pavers
Valuation:
N/A
Permit #:
792989
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Administrative permit
2017-06-27
Amend permit #739853 to make structural updates due to field construction. modifications include reframing the existing wood beam at the rear of the house with a new steel beam and footing/foundation details along the neighboring exterior wall as shown on plans
Valuation:
N/A
Permit #:
785388
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Interior alterations throughout to include drywall throughout moisture resistant drywall in the bathroom and kitchen new windows and doors in existing opening. applicant agrees to limit the construction to comply with ez permit standard for interior alterations dated january 2011. deviation from the standard will result in revocation of this permit and imposition of further penalties.... see more
Valuation:
N/A
Permit #:
669513
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
For the underpinning existing basement foundation walls. concrete basement floor. make opening on masonry wall and install sliding door aat first floor rear. all work shall comply with the approved plans. this work activity will be performed by a cotrator licensed by the city of philadelphia.owners of the adjacent properties shall be notified of this work activity.**post this permit**... see more
Valuation:
N/A
Permit #:
648415
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2015-08-21
Masonry front wall - remove existing front masonry wall. replace with new 4 inch masonry wall an 4 inch brick veneers on existing foundation. windows and doors to comply with emergency egress standards per irc. new door opening for 36 inch door. flash roof to new front. vertical reinforcement every 24 inches. install returns into party walls for structural connection. flash and seal r... see more
Valuation:
N/A
Permit #:
633695
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New brick veneer facade-ez exterior wall coverings- for the application of exterior wall coverings as per attached standard. deviations from this standard will result in permit revocation and require submission of construction plans
Valuation:
N/A
Permit #:
723089
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2015-08-19
For the excavation and underpinning to lower the basement floor level; for the interior alteration throughout an existing attached two story single family dwelling per submitted sealed plan. separate permits required for electric; plumbing and mechanical
Valuation:
N/A
Permit #:
599823
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2016-03-22
Make safe permit - for re-building a rear bay window with in-kind materials as per architect's plan to resolve case #522413. abutting sidewalk must be closed with fencing a minimum of 6 in height. separate streets department permit required for sidewalk closure. a separate permit is required for any additional alterations that are not specifically addressed on case #522413
Valuation:
N/A
Permit #:
678412
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2013-09-12
Remove fallen stucco from back of property and replace with stucco. stucco_-_exterior plaster. installation of these materials shall be in compliance with astmc926 and astmc1063 and the provisions of this code. r703.6.1 lath. all lath and lath attachments shall be of corrosion- resistant materials. expanded metal or woven wire lath shall be attached with 1-1/2-inch-long (38 mm) 11 gag... see more
Valuation:
N/A
Permit #:
494292
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2015-07-07
Ez exterior wall coverings- for the application of exterior wall coverings as per attached standard. deviations from this standard will result in permit revocation and require submission of construction plans
Valuation:
N/A
Permit #:
622787
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2015-07-07
Ez exterior wall coverings- for the application of exterior wall coverings as per attached standard. deviations from this standard will result in permit revocation and require submission of construction plans
Valuation:
N/A
Permit #:
611378
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2011-07-22
Masonry front wall - remove existing 2 story front masonry wall 10 x 20. replace with new 8 inch masonry wall (4 brick & 4 block) on existing foundation. windows and door same location. new door opening for 36 inch door. flash roof to new front. vertical reinforcement every 24 inches. install returns into party walls for structural connection. flash and seal roof. install 2 x 4 frame ... see more
Valuation:
N/A
Permit #:
353924
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2017-05-10
Stucco facade of building with 3 coats of stucco over wire mesh 24'highx 15 wide install 4 windows in facade on existing openings replace front door on existing opening
Valuation:
N/A
Permit #:
782685
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2017-04-12
Ez masonry facade permit- for the application of exterior facade as per attached standard. deviations from this standard will result in permit revocation and require submission of construction plans
Valuation:
N/A
Permit #:
774755
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2011-07-08
Masonry front wall - remove existing _ story front masonry wall _ x _. replace with new 8 inch masonry wall (4 brick & 4 block) on existing foundation. windows and door same location. new door opening for 36 inch door. flash roof to new front. vertical reinforcement every 24 inches. install returns into party walls for structural connection. flash and seal roof. install 2 x 4 frame wa... see more
Valuation:
N/A
Permit #:
351854
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2008-08-19
Remove and replace masonary front wall on existing footing using 4 cmu. replace 4 front windows and exterior door in same location with no change in size or height. no other work allowed on this permit. applicant agrees to limit construction to comply with ez permit standard dated february 2007. deviation from this standard will result in the revocation of this permit and the impositi... see more
Valuation:
N/A
Permit #:
171784
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2008-01-30
2x4 interior partitions/sheetrock throughout 1st, 2nd floors ceilings included. insulate all exterior walls with r-13 or r-19. . separate permits required for electrical plumbing and hvac. masonry veneer front wall on existing footing stucco on rear wall. windows door same size. install brick ties every 24 vertical and 36 horizontal and physical tie in every four foot vertical. flashi... see more
Valuation:
N/A
Permit #:
129594
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2007-11-08
New brick veneer front wall 12x15.wall ties must be installed every 24 verical 36 horizontal , flashing and weep hole also required per irc 2006.windows and doors same size openings.applicant agrees to limit construction to ezpermit standard.deviation from this standard will result in the revocation of this permit and impostion of further penalties
Valuation:
N/A
Permit #:
114512
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Alteration permit
2007-10-11
Brick veneer to existing front wall.footing 36 below grade other requirements needed are weep holes, flashing and brick ties every 24 vertical and 36 horizontal.no change to windows and door openings.applicant agrees to limit construction to ez permit standards.deviation to this standard will result in the revocation of this permit and imposition of further penalties
Valuation:
N/A
Permit #:
108526
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Vilar Construction Reviews

BuildZoom hasn't received any reviews for Vilar Construction. Click here to be alerted when reviews are posted about them.
Please write a review about Vilar Construction
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.