Walsh Brothers Electric LLC
Walsh Brothers Electric LLC, 1170 Old Rushville Rd NE, Rushville, OH (Owned by: Kevin C Walsh) holds a Electrical Contractor license and 1 other license according to the Ohio Professional license board.
Their BuildZoom score of 103 ranks in the top 10% of 52,717 Ohio licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Walsh Brothers Electric LLC, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Walsh Brothers Electric LLC Contact Information
Phone Number: (740) 777-6699
Edit
Address: 1170 Old Rushville Rd NE, Rushville, OH 43150
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Walsh Brothers Electric LLC Rushville
Quality
103
90th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Walsh Brothers Electric LLC has a BuildZoom score of 103, which places them above 90% of 52,717 contractors in Ohio.
Activity
|
7 projects
|
2025 |
|
9 projects
|
2024 |
|
8 projects
|
2023 |
Our building permit records indicate that Walsh Brothers Electric LLC has worked on at least
24.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
6 projects
|
Home Additions |
|
22 projects
|
Electrical projects |
Analyzing permits over the last 4 years shows that Walsh Brothers Electric LLC mostly works on
electrical project
and home addition
projects.
Pricing
|
1 project
|
< $5k |
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
Building Permits by Walsh Brothers Electric LLC
This is a sample of this contractor's permits. Click here to access their complete permit history.
Building permit/plan review: altr2427734 this quote is to repair fire damage in kitchen area. the square footage on the quote covers the kitchen laundry room bathroom next to kitchen and stairway wall next to kitchen 2nd floor bedroom and bathroom. 3rd floor to remain unfinished with the exception of general lights and smoke/co2 detectors per nec replacement of broken boxes and cut sw... see more
Valuation:
N/A
Permit #:
EMEPR2514805
Status:
complete
Fee:
$250
Permit Type:
N/A
Building Type:
N/A
Installation of 100 amp 30 space panel to replace existing ge panel in basement. panel includes all new breakers and separation of all double tapped breakers. installation of gfci outlet next to panel for panel maintenance outlet. #2 seu cable from 100 amp panel to 100 amp meter to remain.existing meter show signs of corrosion on line side lugs and water previously found in panel. no ... see more
Valuation:
N/A
Permit #:
EMEPR2509953
Status:
complete
Fee:
$250
Permit Type:
N/A
Building Type:
N/A
Installation of 3/4” liquid tight conduit from hall way panel 120/208v. through ceiling joist space to exterior soffit. cut in access hole in wall in to fish liquid tight conduit to top of panel additional hole made be needed in ceiling to access wall cavity. installation of 3/4” lb under soffit to terminate liquid tight conduit. installation of emt conduit with weather tight compress... see more
Valuation:
N/A
Permit #:
EMEPC2506767
Status:
complete
Fee:
$500
Permit Type:
N/A
Building Type:
N/A
Installation of garage door opener circuit and dedicated outlet in garage with old work boxes cut into drywall ceiling and wall in garage installation of outlet for garage door opener and gfci outlet for wall outlet. garage door opener and outlet will be fed with 12/2/2 wiring from garage ceiling fished through interior wall to basement room under staircase. installation of dedicated ... see more
Valuation:
N/A
Permit #:
EMEPR2520309
Status:
complete
Fee:
$250
Permit Type:
N/A
Building Type:
N/A
The existing rigid riser will be set back in its original place and strapped. the hour of labor is for resetting the riser and installing the straps. the existing roof boot will be replaced if it is damaged. a rigid riser support kit will be installed on the roof for extra support so that this same issue does not happen again. 12/2/2 wiring will be used to dedicate the fridge and micr... see more
Valuation:
N/A
Permit #:
EMEPR2448661
Status:
complete
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Existing heater in garage area has 208v from panel m on opposite side of garage area fed from breaker 3/5. existing breaker is 20 amp 2 pole breaker with 12 awg thhn/thwn conductors from panel to heater disconnecting switch. existing heater requires a minimum of 24 amps to operate within nec code. nec code also states fixed electric heaters shall be a continuous load @125 percent. wit... see more
Valuation:
N/A
Permit #:
EMEPC2448182
Status:
complete
Fee:
$450
Permit Type:
N/A
Building Type:
N/A
Building permit/plan review: altc2430147 demolish 3 outlets per print to power source as specified. installation of 2 gfci 20 amp breakers in panel exact panel make and model unknown. installation of fuses in existing disconnects to 20 amp fuses exact make and model of disconnect unknown. installation of (2) 6-20 receptacles for new ovens. extend circuitry for coffee maker and additio... see more
Valuation:
N/A
Permit #:
EMEPC2441004
Status:
complete
Fee:
$600
Permit Type:
N/A
Building Type:
N/A
Installation of 4 customer supplied ceiling fans with remote controls. inspection of 1st floor office light box showed box is not fan rated. installation of 4 ceiling fan rated boxes (1) in first floor office (3) in upstairs bedrooms. 2nd floor bedrooms have attic access from hallway
Valuation:
N/A
Permit #:
EMEPR2423622
Status:
complete
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Building permit/plan review: altr2414191 using the approved set of prints: install all boxes in the kitchen. there will be 5 new circuits. the new circuits will be for the refrigerator range kitchen outlets dishwasher and disposal. from the panel run 12/2 to the first box for each new circuit. once all of the home runs are pulled in run 12/2 jumpers for the kitchen outlets (there is a... see more
Valuation:
N/A
Permit #:
EMEPR2419497
Status:
complete
Fee:
$400
Permit Type:
N/A
Building Type:
N/A
Installation of 1 gang old work box and cut in on basement stairway wall. installation of 15 amp outlet for refrigerator. installation of 12/2 romex from panel in basement to new location at basement stairway wall. relocate range outlet and wiring from current location to new location where refrigerator used to be. range circuit is long enough to be moved. current range outlet is rece... see more
Valuation:
N/A
Permit #:
EMEPR2419015
Status:
complete
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Building permit/plan review: altr2412116 using the approved set of prints: install all boxes in the basement for all outlets and switches. there will be 4 new circuits installed: 1 for refrigerator, 1 for bathroom 1 for recreation room and 1 for hallway/panel room. walsh brothers electric llc will run 12/2 from the panel to the first box for each circuit. then run 12/2 jumpers to all ... see more
Valuation:
N/A
Permit #:
EMEPR2416057
Status:
complete
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Installation of emt conduit from 120/240v front panel to dividing wall. conduit will be ran from panel to ceiling then to far side of bay area then across to dividing wall pipe will be ran down interior of wall on grow area side. installation of pvc conduit on interior wall. installation of bell box with nema l14-30r receptacle with in-use cover. installation of thhn wiring from panel... see more
Valuation:
N/A
Permit #:
EMEPC2411284
Status:
complete
Fee:
$450
Permit Type:
N/A
Building Type:
N/A
In the bedroom run a wire to the ceiling and addition a ceiling fan box. install a ceiling fan. in the kitchen run 2 new circuits for a refrigerator and microwave/exhaust. then addition a circuit for the garage so that the garage is on its own circuit
Valuation:
N/A
Permit #:
EMEPR2407281
Status:
complete
Fee:
$200
Permit Type:
N/A
Building Type:
N/A
Wiring for a 50 amp machine and a refrigerator outlet. the 50 amp circuit will come out of the breaker box and run overhead in conduit to where the machine is going to set then it’ll be wired in. the refrigerator outlet will be a dedicated circuit out of the panel. a gfci will be installed with a bubble cover to keep it up to code load calcs required at time of inspection
Valuation:
N/A
Permit #:
EMEPC2316354
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
From the panel in the bedroom run a 10/2 romex to the attic over about 10’ then down the wall about another 10’ to the location of the baseboard heater. then from the baseboard heater in the first bedroom run a 10/2 to the other side of the wall to a baseboard heater in the bathroom. then from the bathroom run a 10/2 up to the attic over about 6’ to the second bedroom to the last base... see more
Valuation:
N/A
Permit #:
EMEPM2352677
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
In the basement addition in 3 lights. addition 2 switches 1 switch to control 1 light near the panel and 1 switch to control 2 lights over art table. run 14/2 from the panel to the switches then from the switches to the lights. addition an outlet with the switch at the art table. both switches will be dimmer switches to control the lighting
Valuation:
N/A
Permit #:
EMEPR2322648
Status:
complete
Fee:
$150
Permit Type:
N/A
Building Type:
N/A
Installation of 60 amp 2 pole bolt on eaton breaker in main panel. installation of 1” pvc conduit surface mounted from main panel to air conditioning disconnect mounted to the right of side exit door. installation of #6 thhn wiring from panel to disconnect through pvc raceway to air conditioning disconnect 60 amp. installation of 60 amp disconnect exact location to be coordinated on site
Valuation:
N/A
Permit #:
EMEPC2326356
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
** no drywall to be removed requiring building permit** (ch) will be moving the kitchen light and garbage disposal switches into a 3 gang old work box with the gfci counter top receptacle. the countertop gfci receptacle is not wired correctly and is not gfci protected. one of the gfcis quoted is for if this device is bad then it will be replaced. the garbage disposal switch will have ... see more
Valuation:
N/A
Permit #:
EMEPR2234773
Status:
complete
Fee:
$150
Permit Type:
N/A
Building Type:
N/A
Building permit/plan review: altc2216621 bathroom #1-demo existing lighting conduit to nearest junction box. installation of 2 light boxes for vanity lights above mirrors and mc wiring from lights to switch bathroom #2-demo existing outlet in ada stall to nearest junction box. use lighting junction box for up lights on opposite side of the wall installation of emt conduit from junctio... see more
Valuation:
N/A
Permit #:
EMEPC2234790
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
12/29/22 - contractor has withdrawn from permit - see doc tab - dbaxter-daniel moving one can light and adding 5 more. adding one gfci behind the washer and dryer. also adding two gfci’s behind the counter top that will be added later. the bathroom will have one light and one gfci added. there will also be a switch added for the can lights and one switch moved. there will be an outlet... see more
Valuation:
N/A
Permit #:
EMEPR2244757
Status:
issued
Fee:
$150
Permit Type:
N/A
Building Type:
N/A
Similar Contractors
License not required
Columbus, OH
124
BZ Score
$12K
Avg Project
-
Projects
126
BZ Score
$11.5K
Avg Project
-
Projects
License # E01989
Columbus, OH
128
BZ Score
-
Avg Project
-
Projects
Walsh Brothers Electric LLC Reviews
BuildZoom hasn't received any reviews for Walsh Brothers Electric LLC. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Verified License
BuildZoom confirmed this contractor's license
Walsh Brothers Electric LLC License info
Verified License
| License # | EL.49569 |
| Status | Active |
| City | Ohio Professional |
| Type | Electrical Contractor |
- BuildZoom verified this license was active as of July 2026.
Verify this license's status for Walsh Brothers Electric LLC at the Ohio Professional License Center.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | E01535 |
| Status | Inactive |
| City | Columbus |
| Type | Electrical Cont |
- According to the The City of Columbus, OH, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Walsh Brothers Electric LLC at the The City of Columbus, OH.
This is a sample of licensing data; click here to access a complete history.
103
BuildZoom Score
31
Permits
- Building permit records show that Walsh Brothers Electric LLC has worked on 31 permitted projects.
Walsh Brothers Electric LLC Employees
KW
Kevin C Walsh
Owner
KW
Kevin C Walsh Walsh