Updated: Mar 13, 2026
Location and Projects
Address
500 North Saint Patrick St., New Orleans, LA, 70119
Use our bidding system to
request a quote
William A Collins III Electrician
William A Collins III, 500 N Saint Patrick St, New Orleans, LA (Employee: William Alexander Collins Iii) holds a Electrical license and 1 other license according to the Louisiana license board.
Their BuildZoom score of 100 ranks in the top 13% of 31,948 Louisiana licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring William A Collins III, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
William A Collins III Contact Information
Phone Number: (504) 304-5007
Edit
Address: 500 North Saint Patrick St., New Orleans, LA 70119
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
William A Collins III New Orleans
Quality
100
87th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
William A Collins III has a BuildZoom score of 100, which places them above 87% of 31,948 contractors in Louisiana.
Activity
|
1 project
|
2025 |
|
3 projects
|
2024 |
|
2 projects
|
2023 |
Our building permit records indicate that William A Collins III has worked on at least
6.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
5 projects
|
Electrical projects |
Analyzing permits over the last 4 years shows that William A Collins III mostly works on
electrical project
projects.
Pricing
|
3 projects
|
< $5k |
|
1 project
|
$5k-$20k |
|
1 project
|
$50k-$100k |
The typical size of their permits is approximately $1,800. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
Building Permits by William A Collins III
This is a sample of this contractor's permits. Click here to access their complete permit history.
: 200 amp temporary power pole w/200 amp meter can panel and 2 - 20 amp circuits with weather proof gfci receptacles for construction/renovation purposes and 2 rod ground system
Valuation:
$1,150
Permit #:
24-17587-LOOP
Status:
filed
Fee:
$40
Permit Type:
N/A
Building Type:
Building use group
: electrical service (since no activity for last 2 years nha do requested another permit to update inspection 11/15/2022)
Valuation:
$72,000
Permit #:
22-34519-SERV
Status:
filed
Fee:
$220
Permit Type:
N/A
Building Type:
Building use group
Installing (1) 200 amp exterior 24 circuit main breaker panel located next to meter. install grounding system to code with 2 ground rods intersystem grounding bar and connection to meter box with #4 awg copper grounding wire. and 28 circuits for renovations
Valuation:
$14,000
Permit #:
19-18299-SERV
Status:
complete
Fee:
$184
Permit Type:
N/A
Building Type:
Building use group
: main service: demolish out the existing meter and stem. install a new 200 amp meter can with a four foot trough with a 2 stem with 90 degree to the front corner with 2/0 copper feeder wires. re-crimp the hot service drop to restore power to the service. upgrade main ground system to code with a #4 ground wire from the meter can to an intersystem ground bar to 2 - 8 ground rods to wa... see more
Valuation:
$16,150
Permit #:
19-30542-SERV
Status:
issued
Fee:
$166
Permit Type:
N/A
Building Type:
Building use group
The main electrical service is with exposed non-fused high voltage wiring traveling/suspended almost the entire length of the left side exterior of the building. the main service is only 125 amp rated and the main breaker panel is without space. no visible ground rods at the current main electrical service location. will relocate the main electrical service to the front left corner of... see more
Valuation:
$14,000
Permit #:
19-15972-SERV
Status:
issued
Fee:
$115
Permit Type:
N/A
Building Type:
Building use group
The exterior of the building is with exposed single strand main power wires suspended/secured along the right side of the house to the main electrical service. will need to relocate the 3 phase meter can to the front right corner where the city wire point of attachment connects to the house. will furnish and install a new 200 amp meter can overhead main power conduit with cables a 200... see more
Valuation:
$9,100
Permit #:
19-13896-SERV
Status:
issued
Fee:
$121
Permit Type:
N/A
Building Type:
Building use group
Main electrical service to consist of a 200 amp single phase service with a 200 amp meter can up to a 15 - 2 stem with 90* to the front corner of the house with 2/0 copper feeder wires main ground system to consist of a #4 ground wire from the meter can to an intersystem ground bar to 2 - 8 ground rods and a 200 amp main breaker eaton cutler hammer ch series 42 circuit outdoor panel l... see more
Valuation:
$10,000
Permit #:
19-02565-SERV
Status:
issued
Fee:
$172
Permit Type:
N/A
Building Type:
Building use group
Approximately 100 from entergy's new tap box install a strut rack with a 100 amp meter can underground fed with a 100 amp main breaker 22 circuit panel. from this location dig a trench to entergy tap box and to the rear of the property line into green space. the trench is to be a minimum of 4 wide by 40 deep. we are to install a 2-1/2 schedule 80 pvc conduit from the meter can locatio... see more
Valuation:
$5,300
Permit #:
19-09701-SERV
Status:
filed
Fee:
$85
Permit Type:
N/A
Building Type:
Building use group
Furnish and install a new 200 amp single phase meter can overhead power conduit and main breaker disconnect same side as existing but closer toward the rear property line approximately 12 feet installing new main power feeder from new main disconnect to the existing main breaker panel in the basement. and 18 circuits for renovations/addition
Valuation:
$14,000
Permit #:
19-08863-SERV
Status:
filed
Fee:
$154
Permit Type:
N/A
Building Type:
Building use group
Furnish and install a new 320 amp single phase meter can trough and one of two main breaker panels all in place of the existing damaged ones. no existing visible reachable branch circuits which previously connected to removed/vandalized breaker panel except one 20 amp 120 volt wire barely visible
Valuation:
$9,000
Permit #:
19-03139-SERV
Status:
filed
Fee:
$160
Permit Type:
N/A
Building Type:
Building use group
: install a new 200 amp meter can with a 2 stem straight up with 2/0 copper feeder wires. wire main ground system to code with a #4 ground wire from the meter can to an intersystem ground bar to 2 - 8 ground rods. install a 200 amp main breaker 42 circuit panel and breakers. and 21 circuits
Valuation:
$14,000
Permit #:
18-36605-SERV
Status:
filed
Fee:
$163
Permit Type:
N/A
Building Type:
Building use group
: furnish and install a new 200 amp two gang meter can connecting to the existing left breaker panel for the other address and a 200 amp 30 circuit main breaker outdoor panel with new breakers connecting to the existing branch circuits leaving room for additional circuits marking the existing circuits for easy identification with a new larger overhead conduit and cables. will correct ... see more
Valuation:
$1,910
Permit #:
19-35765-SERV
Status:
issued
Fee:
$100
Permit Type:
N/A
Building Type:
Building use group
: from the existing house panel tying into the existing photo cell run a half inch conduit behind downspouts up and into the front porch overhang on the right side of the building. fish wiring through the void in the overhang to re-feed the four existing pendant fixtures. cap off the existing feeds in the boxes and install four owner supply led bulbs in the fixtures up on re-installat... see more
Valuation:
$842
Permit #:
19-30337-ERPR
Status:
issued
Fee:
$40
Permit Type:
N/A
Building Type:
Building use group
: furnish and install a new 200 amp two gang meter can connecting to the existing left breaker panel for the other address and a 200 amp 30 circuit main breaker outdoor panel with new breakers connecting to the existing branch circuits leaving room for additional circuits marking the existing circuits for easy identification with a new larger overhead conduit and cables. will correct ... see more
Valuation:
$1,910
Permit #:
19-35764-SERV
Status:
issued
Fee:
$100
Permit Type:
N/A
Building Type:
Building use group
Furnish and install a new cutler hammer brand 100 amps main panel nema 3r main breaker panel in place of existing with new breakers connecting to the existing wiring/circuits and new meter can load wires to the main breaker. no main ground to this service. addition a second ground rod with ground bridge to ground main service. meter can and overhead power conduit to remain
Valuation:
$778
Permit #:
19-24975-SERV
Status:
issued
Fee:
$70
Permit Type:
N/A
Building Type:
Building use group
: wire for furnish and install a 200 amp 3 phase overhead main power conduit utilize existing 200 amp 3 phase meter can new 3 phase fuse disconnect exterior switch box with a new complete #4 ground system consisting of two ground rods ground wire bonding to the main electrical service components and a grounding bridge for communication companies to correctly ground their equipment. th... see more
Valuation:
$4,162
Permit #:
19-37153-SERV
Status:
issued
Fee:
$100
Permit Type:
N/A
Building Type:
Building use group
: main electrical service issues noted: existing service is undersized (100 amp main with a 100 amp circuit feeding 15 kw electric heat and air conditioning plus rest of the house branch breakers) improper brand breakers in the panel main ground system is run loose down wall and across sidewalk to ground rod damage to feeder wire from screw for cover shorting out into the wire burning... see more
Valuation:
$4,767
Permit #:
19-30539-SERV
Status:
issued
Fee:
$136
Permit Type:
N/A
Building Type:
Building use group
: rebuild one damaged meter bank socket for apartment a only with a new 125 amp main breaker and reinstall the 70 amp house breaker. upgrade the main ground system consisting of one additional ground rod #1 green ground wire bonding to the main electrical service components and a grounding bridge for communication companies to correctly ground their equipment
Valuation:
$2,612
Permit #:
19-30508-SERV
Status:
issued
Fee:
$78
Permit Type:
N/A
Building Type:
Building use group
Residential electrical connection, residential electrical permit, service fee (3%)
2020-07-29
Installed new 200 amp single phase meter can and distribution panel on exterior of house. existing meter can and distribution panel located on defective wooden pole.washington power provided new underground service to house
Valuation:
N/A
Permit #:
2020-52812
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Single family
: installing a new 200 amp single phase main electrical service consisting of new 2 over head power conduit turning toward the street 200 amp meter can a cutler hammer brand 200 amp 42 circuit main breaker panel with all new breakers applying arc fault breakers as per the new electrical code requirements and a complete 200 amp rated ground system consisting of 2 ground rods and a grou... see more
Valuation:
$14,000
Permit #:
18-36577-SERV
Status:
issued
Fee:
$163
Permit Type:
N/A
Building Type:
Building use group
Similar Contractors See more
109
BZ Score
$17.3K
Avg Project
-
Projects
License # 54402
Covington, LA
110
BZ Score
-
Avg Project
-
Projects
License # 58792
Slidell, LA
109
BZ Score
-
Avg Project
-
Projects
William A Collins III Reviews
BuildZoom hasn't received any reviews for William A Collins III. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Verified License
BuildZoom confirmed this contractor's license
William A Collins III License info
Verified License
| License # | 48997 |
| Status | Active |
| State | Louisiana |
| Type | Electrical |
| Class | Commercial License Certificate |
- BuildZoom verified this license was active as of March 2026.
Verify this license's status for William A Collins III at the Louisiana Licensing Board.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | 37563 |
| Status | Inactive |
| State | Louisiana |
| Type | Business And Law, Electrical Work (Statewide) |
| Class | Commercial License |
- According to the Louisiana Licensing Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for William A Collins III at the Louisiana Licensing Board.
This is a sample of licensing data; click here to access a complete history.
100
BuildZoom Score
397
Permits
- Building permit records show that William A Collins III has worked on 397 permitted projects.
William A Collins III Employees
WI
William Alexander Collins Iii