Share your project details and we'll reach out to
Zinniel Electric Company
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Zinniel Electric Company at 107 FERGUS AVE STE 1 PO BOX 355, Morgan, MN 56266, held a Electrician license (#EL010507EC) with the Iowa contractors license board with an expiration date of 12-31-2025. We last verified the license was expired on 07-23-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 77,973 Minnesota contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
Supply/install (2) outside rt loadcenters with (1) 50a 120/250v outlet (2) 30a 120v outlet & (1) 20a 120v outlet each supply/install (1) inside loadcenter with (6) 20a 120v duplex receptacles rework of (3) existing 50a 250v outlets and (3) 20a 120v outlets with new 12x12 j-box and addition neutral for (3) added loadcenters wiring of (1) new mini-split air conditioning unit with (... see more
) 120v receptacles on outside of hoop building not working and conduit needs to be resupported 2) move outlet and start/stop station for conditioner grinder from outside backer-board to inside by machine-need to use hammer drill 3)repair conduit on west side of building outside behind leg
Project #1a – 5.74kw roof mount photovoltaic array. located on the south facing back side of house roof project #2a – 10kwhr enphase battery storage project #3a – supply/install of additional 1.64kw photovoltaic array. located on the south facing back side of house lower roof
Existing 150 amp service panel in east half of hog barn was totally burnt. replaced existing service panel with new replaced conduit and service feeders from new outside installed j-box cut back and added new j-box/conduit/wire for (8) branch circuit conduits. installed all new circuit breakers and (2) new 100 amp fuses. verified operation of circuits with owners onsite
Nstalled wiring boxes and devices in new walls for office and separation wall installed motion sensors for gym ares lights and separated from storage area lights removed 2 defective fans from gym area and replaced with fans from storage area relocated t stat to wall next to office installed camera back in entry area panel p1 - 8 circuits panel p2 - 2 circuits
Supply/install of (132) panasonic 400w photovoltaic modules with (132) enphase iq8plus microinverters. the system is divided between 2 roof areas. upper area has (92) photovoltaic modules and the lower area has (40) photovoltaic modules
Relocating existing well pressure tank from outside well house to inside of residental house. need to install underground between existing well and residental house replace existing photocell on outside post light time clock
Rewire cow barn. replace emt with pvc. replace disconnect with new breaker panel install new 30 amp 120-240v underground from site service to machine shop replace 50 amp 4-wire receptacle on grain bin with new
Eliminate existing 480v 3 phase service for old irragation system and step down transformer for well and replace with new 120/240v 1 phase service and refeed existing well. bcrea will be replacing the existing transformer and supply the new 200 amp 1 phase meter socket
Repair exit lights office outlet and wp covers on shop outlets install 4 duplex and 2 gfci weatherproof covers on devices in shop. install 1 duplex receptacle by radio in office. install 2 led exit fixtures above existing doors
30.4kw ground mount photovoltaic array new 600amp service by grain bins 1 400amp feeder to old service 1 200amp feeder to grain bins 1 200 amp feeder to future grain bin
Supply/install (1) 6 electric baseboard heater with on unit thermostat and relocate (1) 120v duplex receptacle to meet code so it is not over baseboard heater
6 circuits storage room light circuit storage room power circuit bathroom circuit water softner circuit water heater circuit well circuit clete zinniel is point of contact for this project 507-920-3992
1) reposition the existing flag pole light on the new flag pole. need bucket boom lift 2) replace existing entry hallway light above flag with new 4 two lamp led strip fixture 3) install owner supplied ceiling fan on existing opening by track light fixture
Supply/install (1) 50 amp 240 volt 4-wire range receptacle in basement storage room supply/install (1) 20 amp 120 volt duplex receptacle in ceiling of basement meeting area for projector
According to the Iowa Department of Public Safety, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Zinniel Electric Company at the Iowa Department of Public Safety.
This is a sample of licensing data; click here to access a complete history.