We'll help you find the right contractor.

Share your project details and we'll reach out to 906 Heating and Cooling so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >
9

Location and Projects

Address
573 Dalton Rd, Skandia, MI, 49885
Use our bidding system to request a quote

906 Heating and Cooling

906 Heating and Cooling at 573 Dalton Rd, Skandia, MI 49885, has a BuildZoom score of 87 and ranks in the top 79% of 167,179 Michigan contractors.

If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.

906 Heating and Cooling Services

Start a project today:

906 Heating and Cooling Contact Information

Address: 573 Dalton Rd, Skandia, MI 49885 Edit

906 Heating and Cooling Reviews
1 out of 5 stars, based on 1 review

  • By Darryl S.
    March 28, 2023
    Furnace Installation
    $4,500

    I decided on 906 Heating & Cooling, a local company, to have a new furnace installed. HUGE expensive mistake! The owner sent his son alone to install the furnace at the end of November. In February, I asked about the permit that should have been in place before the installation. David said the paperwork must have gotten lost in the mail and refiled for the permit. Nothing about the installation was in code. The following is from the inspector’s findings when he finally came in February.

    1. Supply plenum is not properly made to transition between old duck work.
    2. Return air elbow and air filter is too small for the BTU/airflow of new furnace.
    3. Gas piping is on an angle causing stress on it.
    4. Venting is done in 2” PVC pipe and needs to be 3” per manufactures installation manual.

    The owner of 906 Heating & Cooling (David) didn’t inspect the initial furnace installation.
    The installer used an excessive amount of foil tape to hold pieces of sheet metal together and to cover large gaps for a makeshift supply plenum. After a couple weeks, the foil tape was coming loose, sheet metal pieces were separating allowing majority of heat to flow into the basement. I called 906 Heating & Cooling near the end of December to fix the problems. David sent his son alone again who then uses more sheet metal and more foil tape to patch up an already substandard job, and then again didn’t inspect his son’s work.

    906 Heating & Cooling displayed a lack of knowledge installing a furnace and no quality control. Another contractor was called to correct the problems.

    Read more
Please write a review about 906 Heating and Cooling
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.


Building Permits by 906 Heating and Cooling

Sort by: Notable Notable | Date Date | Job Value Job Value
Mechanical
2023-02-14
Furnace change out 2.17.2023 h.o. called. he does not believe the furnace was installed correctly. he had duquaine come and look at it and neither do they. h.o. stated that 906 did the work back in november and also said he had to tell 906 to pull the permit for the work so that it could be inspected. they finally pulled the permit in february. h.o. does not believe that the contracto... see more
Valuation:
N/A
Permit #:
PM230038-FO
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Furnace replacement
Valuation:
N/A
Permit #:
PM220092-MC
Status:
expired
Fee:
$189
Permit Type:
Mechanical
Building Type:
N/A
Mechanical
2020-09-15
Replacement added contractor please verify license info thank you cm
Valuation:
N/A
Permit #:
PM200322-MT
Status:
final
Fee:
$164
Permit Type:
Mechanical
Building Type:
N/A
Furnace
Valuation:
N/A
Permit #:
PM220010-MT
Status:
expired
Fee:
$189
Permit Type:
Mechanical
Building Type:
N/A
Furnace
Valuation:
N/A
Permit #:
PM220009-RE
Status:
issued
Fee:
$197
Permit Type:
Mechanical
Building Type:
N/A
Mechanical
2021-08-04
Replacement
Valuation:
N/A
Permit #:
PM210367-FO
Status:
approved
Fee:
$189
Permit Type:
Mechanical
Building Type:
N/A
Mechanical
2022-12-12
777 pioneer lot #174 furnace changeout
Valuation:
N/A
Permit #:
PM220605-MC
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical
2023-02-28
Furnace replacement
Valuation:
N/A
Permit #:
PM230058-NC
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Boiler replacement
Valuation:
N/A
Permit #:
PM230041-IC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical
2023-02-14
Boiler replacement
Valuation:
N/A
Permit #:
PM230039-NT
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Furnace replacement
Valuation:
N/A
Permit #:
PM200508-NT
Status:
final
Fee:
$162
Permit Type:
Mechanical
Building Type:
N/A
Mini splits (2) with heat pumps
Valuation:
N/A
Permit #:
PM220501-FO
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Boiler changeout
Valuation:
N/A
Permit #:
PM230040-MC
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mini split heat pumps/ac
Valuation:
N/A
Permit #:
PM220499-IT
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Furnace change out
Valuation:
N/A
Permit #:
PM220604-MC
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical
2022-10-21
Furnace replacement
Valuation:
N/A
Permit #:
PM220498-FO
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Mechanical
2022-10-21
Furnace
Valuation:
N/A
Permit #:
PM220500-SA
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Commons buiding
Valuation:
N/A
Permit #:
PM210024-MC
Status:
expired
Fee:
$168
Permit Type:
Mechanical
Building Type:
N/A

Similar Contractors See more

License # 8110882
103
BZ Score
-
Avg Project
-
Projects
License # 7117834
102
BZ Score
-
Avg Project
-
Projects
License # 8113135
101
BZ Score
-
Avg Project
-
Projects