Updated: May 16, 2026
Location and Projects
Address
5740 Roseville Rd Suite F Sacramento Ca, Sacramento, CA, 95842
Use our bidding system to
request a quote
Bonham Electric
Bonham Electric, 5740 Roseville Rd, Sacramento, CA (Owned by: Ralph Harvey Bonham) holds a Electrical license and 3 other licenses according to the California license board.
Their BuildZoom score of 118 ranks in the top 1% of 336,931 California licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Bonham Electric, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Bonham Electric Services
Start a project today:
Bonham Electric Contact Information
Phone Number: (530) 906-9215
Address: 5740 Roseville Rd Suite F Sacramento Ca, Sacramento, CA 95842
Bonham Electric Sacramento
Quality
118
99th percentile
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
Bonham Electric has a BuildZoom score of 118, which places them above 99% of 336,931 contractors in California.
Activity
|
1 project
|
2026 |
|
7 projects
|
2025 |
|
8 projects
|
2024 |
|
13 projects
|
2023 |
Our building permit records indicate that Bonham Electric has worked on at least
29.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Experience
|
29 projects
|
Electrical projects |
Analyzing permits over the last 4 years shows that Bonham Electric mostly works on
electrical project
projects.
Pricing
|
17 projects
|
< $5k |
|
10 projects
|
$5k-$20k |
|
1 project
|
$20k-$50k |
The typical size of their permits is approximately $4,250. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Miscellaneous electrical plumbing mechanical solar/pv electric vehicle charger generator (not for re
2025-04-28
Provide square d 12 circuit panel in corner of garage behind the side door. the homerun will run in the ceiling of the garage down the exterior wall and stub out near the side wall and travel appox 45ft to the corner trench down across the walkway to the garage. provide (6) duplex receptacles with (2) 20 amp gfi protected circuits and (3) led flat panels
Valuation:
$4,500
Permit #:
MISR2025-01065
Status:
final
Fee:
$253
Permit Type:
N/A
Building Type:
N/A
Electrical permit: 6985 24th street/6699 24th street-for building. d units 1-18 replacement of 18 existing sub panels like for like. carbon monoxide & smoke alarms required. reference crc sections r315 & r314
Valuation:
$15,000
Permit #:
COM-2500253
Status:
final
Fee:
$469
Permit Type:
N/A
Building Type:
N/A
Electrical service panel replacement or emergency repair only. no additional electrical mechanical plumbing or structural work permitted.; overhead panel replacement
Valuation:
$4,000
Permit #:
PANR2025-00545
Status:
complete
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Electrical permit: for building. a: replacement if 18 existing subpanels. in an 18 unit apartment complex. each sub- panel will be powered by its corresponding 40-amp breaker which is controlled by individual utility meters. carbon monoxide & smoke alarms required. reference crc sections r315 & r314
Valuation:
$15,000
Permit #:
COM-2425045
Status:
final
Fee:
$469
Permit Type:
N/A
Building Type:
N/A
Residential: full review - additions adu accessory structures pools remodel demolish generators and
2024-10-07
New standby kohler generator & mpu install new 20kw/200 amp standby kohler generator & mpu transfer switch remove existing 8.5kw and 100 amp champion generator and replace with new 20kw kohler generator with 200amp rated transfer switch. provide new sub panel to accommodate all of the circuits that were put into existing champion transfer switch *** placer hill fire district** *** sra... see more
Valuation:
$16,740
Permit #:
BLD24-05071
Status:
issued
Fee:
$500
Permit Type:
Accessory
Building Type:
N/A
Like for like panel change out (keeping the main breaker size at 100 amps) in the same location at 8213 highwood way per ander lu include a permanent tile tag on the inside of the panel that states: do not upsize main breaker without contacting smud distribution line design
Valuation:
$4,000
Permit #:
PANR2024-00564
Status:
complete
Fee:
$170
Permit Type:
N/A
Building Type:
N/A
Electrical service panel replacement or emergency repair only. no additional electrical mechanical plumbing or structural work permitted.; upgrade 100amp panel to 125amp panel over head. installing a 8.5kw home standby generator
Valuation:
$8,000
Permit #:
PANR2024-00945
Status:
issued
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Electrical permit: for 6943 6929 24th street- building. b replacement of 18 existing sub panels like for like. carbon monoxide & smoke alarms required. reference crc sections r315 & r314
Valuation:
$15,000
Permit #:
COM-2427408
Status:
final
Fee:
$469
Permit Type:
N/A
Building Type:
N/A
Miscellaneous water heater electrical plumbing hvac mechanical solar/pv electric vehicle equip. gene
2022-06-06
80 run of 6-3 romex to get a gfi spa breaker on the back corner of the house. continue from he gfi enclosure approx 37ft with 40 pvc conduit at 18 below grade. pull in (3) #6 thhn and #10 ground stub up and connect to spa with n.m seal tight conduit
Valuation:
$1,500
Permit #:
MISR2021-06346
Status:
complete
Fee:
$136
Permit Type:
N/A
Building Type:
N/A
Miscellaneous electrical plumbing mechanical solar/pv electric vehicle charger generator (not for re
2025-01-27
Install new 20'-2 riser with brace kit new riser wire head. current riser is bent
Valuation:
$2,000
Permit #:
MISR2025-00149
Status:
complete
Fee:
$165
Permit Type:
N/A
Building Type:
N/A
Miscellaneous water heater electrical plumbing hvac mechanical solar/pv electric vehicle equip. gene
2021-11-18
Removed the existing riser cable service head and roof jack. provide a 2 threaded conduit from the existing ge service up and elbow to the left the horizontal approx 21ft elbow conduit up through the overhang and provide a minimum of 24 above the roof for smud to attach the new service drop. (subject to field inspection)
Valuation:
$2,000
Permit #:
MISR2021-10443
Status:
issued
Fee:
$136
Permit Type:
N/A
Building Type:
N/A
Electrical permit: replace 18 existing sub panels like for like. carbon monoxide & smoke alarms required. reference crc sections r315 & r314
Valuation:
$15,000
Permit #:
COM-2427424
Status:
final
Fee:
$469
Permit Type:
N/A
Building Type:
N/A
Panel upgrade from 100 amps to 200 amp overhead service with relocation about 10-12ft out towards the pole. set on new addition
Valuation:
$3,000
Permit #:
PANR2023-00103
Status:
complete
Fee:
$169
Permit Type:
N/A
Building Type:
N/A
Miscellaneous electrical plumbing mechanical solar/pv electric vehicle charger generator (not for re
2025-03-05
New install for 20kw generator and transfer switch
Valuation:
$9,000
Permit #:
MISR2025-00451
Status:
complete
Fee:
$459
Permit Type:
N/A
Building Type:
N/A
E-permit: applicant's detailed description: 125 amp 125 amp like for like panel; existing panel 125 amps - underground service new main panel 125 amps replacement weather head/masthead work main breaker replacement
Valuation:
$3,000
Permit #:
BP21-07358
Status:
final
Fee:
$193
Permit Type:
N/A
Building Type:
N/A
Miscellaneous water heater electrical plumbing hvac mechanical solar/pv electric vehicle equip. gene
2022-06-03
Removed old zinsco exterior sub panel and the existing electrical conduits that do not meet code or in need of repair. install new square d panel 100 amp
Valuation:
$3,000
Permit #:
MISR2022-03890
Status:
complete
Fee:
$281
Permit Type:
N/A
Building Type:
N/A
E-permit: existing panel 100 amps - underground service n/a weather head/masthead work main breaker replacement
Valuation:
$279
Permit #:
RES-2301195
Status:
final
Fee:
$85
Permit Type:
N/A
Building Type:
Duplex
Residential: limited review - electrical mechanical plumbing roof solar etc
2020-10-02
Installing 16 panasonic 330 watt modules with 16 enphase micro inverters behind each module. 5280 dc watt system install location: on the house and attached garage south roof current main amperage: 200 panel changeout: no e-msp with n-30a/2p photovoltaic breaker n-30a disc n-pv combiner box proposed amperage: 200 inverter type/size: 16 enphase micro inverters iq7x-96-2-us number of pa... see more
Valuation:
$20,800
Permit #:
BLD20-03872
Status:
complete
Fee:
$196
Permit Type:
Alteration
Building Type:
N/A
Miscellaneous water heater electrical plumbing hvac mechanical solar/pv electric vehicle equip. gene
2020-09-24
1. demolition: remove old meter panel riser roof jack and service head and any materials necessary to install a new 100 amp sub-panel where the existing main service is located. install 1 1/4 emt conduit with #1 wire from the sub to the main panel. 2. new panels; provide a new 200 amp meter and all new breakers at the new legal location with a new 2 riser service entrance conductors r... see more
Valuation:
$5,860
Permit #:
MISR2020-07722
Status:
issued
Fee:
$320
Permit Type:
N/A
Building Type:
N/A
Aa: existing panel 100 amps - overhead service new main panel 200 amps new install weather head/masthead work main breaker replacement smoke & carbon monoxide alarms required per crc sections r314 & r315. access to perform inspection/s must be provided by the party requesting the inspection
Valuation:
$3,875
Permit #:
RES-2012618
Status:
final
Fee:
$94
Permit Type:
N/A
Building Type:
Single family
Recent Buildzoom Projects
Hiring a contractor?
Verified License
BuildZoom confirmed this contractor's license
Bonham Electric License info
Verified License
| License # | 905104 |
| Status | Active |
| State | California |
| Type | Electrical |
| Business Type | Sole Ownership |
- BuildZoom verified this license was active as of May 2026.
Verify this license's status for Bonham Electric at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | 1004547 |
| Status | Active |
| State | California |
| Type | Electrical |
| Business Type | Sole Ownership |
- When BuildZoom last verified this license, it had an expiration date of June, 2023. Check the current license status of Bonham Electric with the California Contractors State License Board
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | 905104 |
| Status | Active |
| State | California |
| Type | Electrical |
| Class | C10 |
| Business Type | Sole Ownership |
- When BuildZoom last verified this license, it had an expiration date of April, 2026. Check the current license status of Bonham Electric with the California Contractors State License Board
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | 1004547 |
| Status | Active |
| City | Rocklin |
| Type | Contractor |
| Business Type | Sole Ownership |
- When BuildZoom last verified this license, it had an expiration date of June, 2019. Check the current license status of Bonham Electric with the The City of Rocklin, CA
This is a sample of licensing data; click here to access a complete history.
118
BuildZoom Score
Insured
| Insurer | State Compensation Insurance Fund |
Bonded
| Bonded Agent | Hudson Insurance Company |
| Bond Value | $12,500 |
Insured
| Workers Comp Provider | State Compensation Insurance Fund |
211
Permits
- Building permit records show that Bonham Electric has worked on 211 permitted projects.
Bonham Electric Employees
DB
Derek Joe Bonham
Officer
KB
Karl Ray Bonham
Rmo
RB
Ralph Harvey Bonham
Owner
TP
Thomas Whitney Pursell
Ceo / President
Bonham Electric has performed a variety of tasks for me in my home over the years; all were done efficiently and with great care. Most recently, Austin moved a wall oven service box for me to accommodate a new wall oven I had ordered. Previously Bonham E has installed new recessed LED lighting, bathroom and kitchen fans, outlets (one with remote control that Ralph Bonham suggested for my disabled brother), and more. All were done well with no issues. I highly recommend Bonham Electric.