Location and Projects
Address
P O BOX 792031, Paia, HI, 96779
Use our bidding system to
request a quote
Douglas B Miller Construction
Their BuildZoom score of 98 ranks in the top 16% of 3,768 Hawaii licensed contractors.
If you are thinking of hiring Douglas B Miller, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Douglas B Miller Services
Start a project today:
Douglas B Miller Contact Information
Address: P O BOX 792031, Paia, HI 96779
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Project thomas harrison.....new pool & spa scope 1 receptacle 1 switch 4 fixtures 3 motors over 1 to 3 hp. ========================================================================================== 12/02/19 - owner may apply for a miscellaneous inspection to final this permit - cnf ========================================================================================== 01/24/2020 - ... see more
Valuation:
N/A
Permit #:
E 20042312
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project mary beth kahn.......new swimming pool/spa. scope 1 receptacle 1 switch 2 fixtures 2 motors over 1 to 3hp. ========================================================================================== 08/18/2020 - homeowner may apply for a miscellaneous inspeciton to r/c and final this permit - cnf ==================================================================================... see more
Valuation:
N/A
Permit #:
E 20051703
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
Parks outdoor sta...
Project daniel asao.....new swimming pool scope 1 feeder not over 100 amp 1 receptacle 1 switch 1 fixture 1 motor not over 1 hp. ========================================================================================== 11/06/19 - miscellaneous inspection fee of $ 68.00 paid by laura florentino to final this permit - cnf
Valuation:
N/A
Permit #:
E 20040192
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project wendy pogni.......revamp meter loop up-grade service and repair & replace (due to termite damage & dry rot) exterior doorways replace exterior siding ( six of seven exterior walls) replace three winows/install gyp board on all interior partition walls. scope overhead service 1 phase 3 wire 120/240 volt 200 amp 1 feeder over 100 amp to 200 amp 35 receptacles 20 switches 30 fixt... see more
Valuation:
$11,000
Permit #:
E 20042871
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project jeffrey kaiser.........1st farm dwelling..........a/c motors scope 2 motors over 1 to 3hp additional fees to electrical permit no. 2005/0253
Valuation:
N/A
Permit #:
E 20051954
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
Single-family hou...
Project: monsanto scope: mokulele farm - entrance upgrade. new guard house and fence. electrical work includes new empty conduit between new guard house and exist. building approx. 200-ft north of new guard house. fee summary: 1 x 200lf empty raceway project electrical engineer: mark p. rickard pe 8991-e
Valuation:
N/A
Permit #:
E 20161935
Status:
OPEN
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project: monsanto scope: tfs warehouse - receptacle installation. electrical work includes installation of meltric receptacles (3 relocated 1 new) power receptacles (2) gfci receptacles (8 on 3 circuits) fee summary: 9 receptacle branch circuit project electrical engineer: daniel a. schendel pe 8980-e
Valuation:
N/A
Permit #:
E 20161872
Status:
OPEN
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project: smith christopher *****after the fact ***** scope: main dwelling - after the fact interior renovations. replace existing damaged service with a new 200a service with a feeder. after the fact electrical work - added laundry room with one 20a circuit and one 30a circuit. relocated entry switch box fot the living room lights and entry lights. relocated vanity light counter outle... see more
Valuation:
N/A
Permit #:
E 20161878
Status:
OPEN
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project: michael & wendy giblin scope: main farm dwelling - 1st floor: driveway retaining wall garage/workshops storage bathroom terrace whirlpool equip bunker; 2nd floor: portico foyer living/dining/kitchen master bdrm/bath study 3 bdrms 2 baths laundry deck covered lanai master terrace whirlpool. electrical work to install a new 200a service equipment with a new feeder. install new ... see more
Valuation:
N/A
Permit #:
E 20161845
Status:
OPEN
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project advanced pacific scope new medical ent (ear nose throat) office. floorplan first floor only reception waiting billing office storage 4 physician's offices 7 exam rooms 2 nurse station injection recovery audio testing booth audiologists office audiology hearing aid & fitting staff lounge it closet/storage patient restroom restroom. electrical work includes new panelboards a and... see more
Valuation:
N/A
Permit #:
E 20161816
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project 808 tortilla company scope unit #e6 - commercial kitchen. floorplan - kitchen walk-in cooler dry storage prep dish wash restroom. electrical work includes new tortilla making equipment. new refrigeration equipment. new lighting & receptacles. fee summary 1 motor 1-3hp 1 motor 8-15hp 1 refrigeration control wiring 1 lighting branch circuit 1 receptacle branch circuit 10 cooking... see more
Valuation:
N/A
Permit #:
E 20161778
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project 419 front street scope replacement dwelling - 1st floor garage 1 bedroom 1 1/2 bathroom outdoor shower laundry room media room pool equipment room. 2nd floor 4 bedroom 4 bathroom deck. electrical work to install a new 200a service equipment with new feeders. install new receptacles switches luminaires smoke detectors. install new range/oven dryer water heater disposal range ho... see more
Valuation:
$960,000
Permit #:
E 20161487
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project rhonda fulton scope new grid-tied photovoltaic solar power system which consist of 3 arrays for a total of 44-285 watt solar world modules with 44-215 watt enphase micro-inverter. array #1 16-285 watt solar world modules with 16-215 watt enphase micro-inverter. array #2 16-285 watt solar world modules with 16-215 watt enphase micro-inverter. array #3 12-285 watt solar world mo... see more
Valuation:
N/A
Permit #:
E 20161486
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project lewis everett scope workshop/ag storage/half-bathroom w storage/laundry third structure on property electrical wiring to install feeders 50kw transformer motors lighting & receptacle branch circuits dryer 1ph water heater. fee summary 1 feeder not over 100a 1 feeder over 100a to 200a 2 transformers-50kva 1 motor over 1hp to 3hp 2 lighting branch circuits 6 receptacle branch ci... see more
Valuation:
$120,000
Permit #:
E 20161104
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project roddenberry residence *** demolish permit for existing pool & spa t2015-0847 *** scope swimming pool 2 spas bar covered trellis electrical work to install a feeder to a sub-panel pool pumps pool heater pool lites fee summary 1 feeder not over 100a 10 luminaires 3 pool heaters 7 motors over 1hp to 3hp
Valuation:
$60,000
Permit #:
E 20161251
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project lewis everett scope 1st farm dwelling (to be reviewed as 2nd farm dwelling); covered lanai w/outdoor shower; bridge to detached garage. electrical wiring to install a new 200a service equipment with feeders. install new receptacles switches luminaires smoke detectors range/oven dryer water heater disposal range hood dishwasher exhaust fans ceiling fans step-up transformer(75kv... see more
Valuation:
$300,000
Permit #:
E 20161105
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project: nancy saunders scope: new grid-tied photovoltaic solar power system which consist of 2 arrays for a total of 32-285 watt solar world modules with 32-250 watt enphase micro-inverter. array #1: 16-285 watt solar world modules with 16-250 watt enphase micro-inverter. array #2: 16-285 watt solar world modules with 16-250 watt enphase micro-inverter. panels & enphase inverters mou... see more
Valuation:
N/A
Permit #:
E 20161040
Status:
OPEN
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project kit carlan scope new grid-tied photovoltaic solar power system which consist of 1 array for a total of 16-285 watt solar world modules with 16-250 watt enphase micro-inverter. panels & enphase inverters mounted on rooftop of existing 3 bedroom/2 bathroom dwelling built in 1988. fee summary 1 feeder not over 100a (1)renewable energy system
Valuation:
N/A
Permit #:
E 20160947
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project kit carlan scope new grid-tied photovoltaic solar power system which consist of 3 arrays for a total of 41-285 watt solar world modules with 41-250 watt enphase micro-inverter. array #1 16-285 watt solar world modules with 16-250 watt enphase micro-inverter. array #2 16-285 watt solar world modules with 16-250 watt enphase micro-inverter. array #3 9-285 watt solar world module... see more
Valuation:
N/A
Permit #:
E 20160945
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Project edward j romero scope new grid-tied photovoltaic solar power system which consist of 2 arrays for a total of 34-300 watt solar world modules wired as 2 strings of 17 connected to 1-solar edge 10000 watt inverter. panels mounted on rooftop of existing 7 bedroom/4 bathroom dwelling built in 1989. inverter mounted next to meter main on this same structure. fee summary 1 feeder no... see more
Valuation:
N/A
Permit #:
E 20160848
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
License # CT-35326
Honolulu, HI
141
BZ Score
$20K
Avg Project
-
Projects
133
BZ Score
$26K
Avg Project
-
Projects
Douglas B Miller Reviews
BuildZoom hasn't received any reviews for Douglas B Miller. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Douglas B Miller License info
License Not Verified
| License # | CT-32076 |
| Status | Active |
| State | Hawaii |
| Type | B General Building |
| Business Type | Individual |
- When BuildZoom last verified this license, it had an expiration date of September, 2022. Check the current license status of Douglas B Miller with the Hawaii Department of Commerce & Consumer Affairs
This is a sample of licensing data; click here to access a complete history.
License Not Verified
| License # | CT-22347 |
| Status | Active |
| State | Hawaii |
| Type | Electrical Contractor |
| Business Type | Individual |
- When BuildZoom last verified this license, it had an expiration date of September, 2022. Check the current license status of Douglas B Miller with the Hawaii Department of Commerce & Consumer Affairs
This is a sample of licensing data; click here to access a complete history.
98
BuildZoom Score
503
Permits
- Building permit records show that Douglas B Miller has worked on 503 permitted projects.