We'll help you find the right contractor.

Share your project details and we'll reach out to Electrical Systems so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

E

Location and Projects

Address
2418 Auto Park Way, Escondido, CA, 92029
Use our bidding system to request a quote

Electrical Systems

Electrical Systems, 2418 Auto Park Way, Escondido, CA (Owned by: Garold Seton Uyeda) holds a Low Voltage Systems, Electrical license and 3 other licenses according to the California license board.

Their BuildZoom score of 89 does not rank in the top 50% of California contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Electrical Systems, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.

Electrical Systems Contact Information

Phone: (760) 745-3604
Address: 2418 Auto Park Way, Escondido, CA 92029

Electrical Systems Escondido

Quality

89
30th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Electrical Systems has a BuildZoom score of 89, which places them above 30% of 336,931 contractors in California.

Activity

4 projects
2025
4 projects
2024
5 projects
2023
Our building permit records indicate that Electrical Systems has worked on at least 13.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

11 projects
Electrical projects
Analyzing permits over the last 4 years shows that Electrical Systems mostly works on electrical project projects.

Pricing

3 projects
< $5k
Value Not Public: 10.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Electrical Systems Reviews
1 out of 5 stars, based on 1 review

  • October 23, 2015

    I was very disappointed in the service I received from knight security. Brad Mates, the Vice President was very unprofessional. He would not return any of my calls regarding the poorly installed security system he designed. I had many false alarms and was charged hundreds of dollars by the police department. I tried to contact Brad Mates about this but he still will not return my calls now that he has my money. I suggest you find an alarm company who at least tries to be professional.

Please write a review about Electrical Systems
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.


Building Permits by Electrical Systems

Sort by: Notable Notable | Date Date | Job Value Job Value
Extend existing wiring for house lift in garage. remove fpe panels for insurance install new 200 amp meter/main outside. run 2 inch rigid conduit up outside of home to roof line for pge connection. install 2 new ground rods tie into water main bond gas and hot water heater. addition 1 gfi 1 switch and light 1 new circuit for garage door
Valuation:
N/A
Permit #:
EW202410232011
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Upgrade service 200amp 2 ground rods bond gas water main. 30 4 inch led new construction cans ic air tight. 16 switches 40 outlets. remove old knob and tube wiring from dinning room living room 2 bedrooms. new master bathroom 1 panasonic fan 1 20 amp gfi circuit all new circuits to be arc fault protected
Valuation:
N/A
Permit #:
EW202206104031
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Whole house re-wire 2 new bathroom 1 kitchen all circuits to be arc fault as per code. kitchen-9new circuits, dish/dips micro.2 counter stove/hood, lighting.refer bath- 2new 20amp for gfi plugs. each room have 1-20 amp circuit. 38 recessed led lts 27 surface lts 35 switches 68 plugs. 7 smoke 2 smoke/carbon
Valuation:
N/A
Permit #:
EW202111189809
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Service up grade 200 amps single meter. addition 2 ground rods attache to watermain bond gas new weatherhead outdoor. 2 led lights 1 switch 1 panasonic fan 1 switch new 20 amp circuit for gfi plug. 1/2 bathroom new 20 amp gfci plug on arc fault line
Valuation:
N/A
Permit #:
EW202102233658
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Re-locate new 200 amp service already green tagged. pge says to close to gas meter 6 inches had to move to left
Valuation:
N/A
Permit #:
EW202204172837
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Repair wire in main private service (short) voltage drops. install larger panel for kitchen bathroom remdodel. @ new counter circuits dish/disp, new seperate circuits refer, stove ign, hood seperate circuit new lighting circuit bathroom gfi new 20 amp circuit. bedroom 20 amp arc fault circuit (3). 2 smokes 1 smoke/carbon hard wire. all circuits to be on arc fault
Valuation:
N/A
Permit #:
EW202002296978
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
200 amp grade service 2 ground rods bond main water gas hot water heater 100 amp sub panel 10 arc fault 20 amp circuits 2 15 amp arc fault circuits. kitchen- 2 counter circuits dish/disp seperate circuits viking fridge microwave seperate circuits 16- 4 inch led recessed lts bathroom 20 amp circut panasonic fan 2 smoke 1 smoke carbon detectors
Valuation:
N/A
Permit #:
EW201911194989
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Install new 100 amp service to replace existing 40 amp 110 volt system. new 220v 2 ground rods bond hot water heater water main and gas
Valuation:
N/A
Permit #:
EW202307082400
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace baseboard heater
Valuation:
N/A
Permit #:
EW202504035404
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Re-model bathroom 1 new 20 amp gfi circuit 1 new 15 amp lighting circuit 1 wall sconce 2 led recessed lts
Valuation:
N/A
Permit #:
EW202204102682
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Addition sub panel 60 amp kitchen addition new circuis for 2 counters dish/disp stove hood 1 surface mounted led bathroom addition fan update 2 lights led 4 inch 6 switches 6 wall sconces 2 led down lts 1 ceiling surface mounted lt. 3 smoke detectors (smoke/carbon combo) on 1 1 outdoor gfi switch and light
Valuation:
N/A
Permit #:
EW201901118044
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
New 200 amp service 2 ground rods bond hotwater heater and main water. run 1.1/2 rigid conduit up rear of home. kitchen remodel new 40 amp cooktop 2 counter circuits new microwave disposal, refer hood. 1 ceiling led surface light
Valuation:
N/A
Permit #:
EW201904150096
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Service upgrade 200 amps 2 ground rods bond hot water heater
Valuation:
N/A
Permit #:
EW202506207341
Status:
filed
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replace fpe panels with new 200 amp service. 1 1/2 rigid conduit up side of house 2 new 200 amp meter sockets 2 new outdoor 125 amp panels. 2 ground rods ground main water gas. bond hot water heater
Valuation:
N/A
Permit #:
EW201903189453
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Addition new sub panel (80 amps) re-wire whole unit. 6 switches 6 ceiling fixtures new seperate bathroom gfi outlet 3-20 amp arcfault circuits 2 15-amp lighting circuits 3 smoke/carbon units dish/disp micro/hood 2 counter kitchen circuits refer stove ingnition
Valuation:
N/A
Permit #:
EW201709087868
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Addition new meter and panel for new unit. 4-arc fault plug circuits 2-arc fault lighting circuits 1 new 20 amp circuit for bathroom 2- kitchen counter circuits dish/disp (2) circuits micro/hood circuit refer stove ignition 3 smoke/carbon detectors. 10 switches 25 outlets 12 lights
Valuation:
N/A
Permit #:
EW201709137948
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Addition 80 amp sub panel for kitchen remodel. new dish/disp 2 counter circuits stove refer hood. 8 led 4 inch recessed lts 4 switches
Valuation:
N/A
Permit #:
EW202006158422
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Approval - construction - fire pmt - alarm
2024-03-15
Approval - construction - fire pmt - alarm:9097/kenamar
Valuation:
N/A
Permit #:
PMT-3280008
Status:
complete
Fee:
$416
Permit Type:
N/A
Building Type:
N/A
Approval - construction - fire pmt - alarm
2024-02-06
Approval - construction - fire pmt - alarm:5629/copley
Valuation:
N/A
Permit #:
PMT-3272504
Status:
complete
Fee:
$416
Permit Type:
N/A
Building Type:
N/A
100 amp service upgrade. run no 4 thhn ground to 2 ground rods attach to main water. bond hot water heater gas. 1inch and quarter rigid steel with no2 thhn feed
Valuation:
N/A
Permit #:
EW201902279036
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A