×

Don't wait to get a Plumber

We make finding a plumber fast, easy, and commitment-free.

Call now (623) 745-8065
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >

Location and Projects

Address
1215 POLARIS PKWY #217, Columbus, OH, 43240
Use our bidding system to request a quote

Epro Services Plumber

Epro Services, 1215 Polaris Pkwy, Columbus, OH (Owned by: Paul Barginesi) holds a Fire Protect Co license and 2 other licenses according to the Columbus license board.

Their BuildZoom score of 110 ranks in the top 4% of 52,717 Ohio licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Epro Services, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Epro Services Contact Information

Phone: (614) 212-7739 Edit
Address: 1215 POLARIS PKWY #217, Columbus, OH 43240 Edit

Epro Services Columbus

Quality

110
96th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Epro Services has a BuildZoom score of 110, which places them above 96% of 52,717 contractors in Ohio.

Activity

17 projects
2025
21 projects
2024
20 projects
2023
Our building permit records indicate that Epro Services has worked on at least 58.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

4 projects
Commercial Renovations
3 projects
Home Additions
17 projects
Plumbing projects
Analyzing permits over the last 4 years shows that Epro Services mostly works on plumbing project and commercial renovation projects.

Pricing

3 projects
< $5k
Value Not Public: 53.0 projects
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Epro Services

Sort by: Notable Notable | Date Date | Job Value Job Value
Fire alarm | commercial
2025-02-05
Alter existing fire alarm system for watkins elementary school by replacing failing facp annunciator and nacs. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided until the system(s) have been returned to... see more
Valuation:
N/A
Permit #:
FALRC2445105
Status:
complete
Fee:
$413
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2025-09-08
Alter existing manual fire alarm system for new change of use banquet and food court space (pulls smokes notification ducts). system to supervise sprinkler system kitchen hood suppression system and elevator recall. reference b.p. altc2427591 - (28) devices
Valuation:
N/A
Permit #:
FALRC2528520
Status:
issued
Fee:
$491
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2025-08-25
Alter existing manual and automatic fire alarm system for holiday inn by removing 2 non-required from over the pool area. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided until the system(s) have been ... see more
Valuation:
N/A
Permit #:
FALRC2516214
Status:
complete
Fee:
$407
Permit Type:
N/A
Building Type:
N/A
Commercial | plans revision
2025-02-10
Revision to fire alarm permit falrc2413476. revision is to relocate the faap and show the 2 notification devices that were missing on the original plans
Valuation:
N/A
Permit #:
PLRE2503950
Status:
complete
Fee:
$450
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-11-27
Alter existing manual fire alarm system for accel school by installing new notification devices and upgrade existing ones. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided until the system(s) have been... see more
Valuation:
N/A
Permit #:
FALRC2429493
Status:
complete
Fee:
$429
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-11-26
Alter existing manual fire alarm system for fairwood elementary by removing and relocating duct detectors due to mechanical renovations. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided until the syste... see more
Valuation:
N/A
Permit #:
FALRC2430581
Status:
complete
Fee:
$403
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-10-23
Alter existing manual fire alarm system for city of columbus by replacing faap with new one and adding smoke detector above it as well as changing two smoke detectors to heat detectors. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or a... see more
Valuation:
N/A
Permit #:
FALRC2430575
Status:
complete
Fee:
$413
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-10-17
Alter existing fire alarm system for america's best value inn by replacing smoke heat detectors throughout building. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided until the system(s) have been retu... see more
Valuation:
$1,000
Permit #:
FALRC2420203
Status:
complete
Fee:
$1,468
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-10-18
Alter existing fire alarm system in forest park modular unit building by replacing facp and associated devices pull notification smokes. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided until the syste... see more
Valuation:
N/A
Permit #:
FALRC2435303
Status:
complete
Fee:
$416
Permit Type:
N/A
Building Type:
N/A
Commercial | plans revision
2024-05-13
Revision to fire alarm permit falrc2412427. revision is to replace combo devices with smoke only in non-fuel burning units only
Valuation:
N/A
Permit #:
PLRE2416999
Status:
complete
Fee:
$450
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-01-12
Revision plre2415650 approved 5/2/24. revision to fire alarm permit falrc2352645. revision is to relocated strobes and smoke detectors within the same unit revision plre2407183 approved 2/26/24. revision to fire alarm permit falrc2352645. revision is to move smokes to bedroom areas alter existing manual fire alarm system for 888 apartments by installing new devices in ne portion of bu... see more
Valuation:
N/A
Permit #:
FALRC2352645
Status:
issued
Fee:
$1,016
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-03-29
Emergency permit filing - fire panel currently in trouble - need to replace - replacing existing panel with potter ipa 100 - installing new smoke above fire panel - replacing 12 pull stations - 9 av - 1 annunciator. certified drawing are be created and will be submitted for approval
Valuation:
N/A
Permit #:
FALRC2413476
Status:
corrections required
Fee:
$475
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2024-05-16
Revision plre2416999 approved 5/13/24. revision to fire alarm permit falrc2412427. revision is to replace combo devices with smoke only in non-fuel burning units only replacing 87 smoke detector heads in guest rooms & 25 smoke/co heads in other areas that are all existing. these new devices system sensor sk-photo-w & sk-photo-co-w are compatible with the existing system and like exist... see more
Valuation:
N/A
Permit #:
FALRC2412427
Status:
complete
Fee:
$767
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2025-06-02
Alter existing manual fire alarm system for the feast buffet by installing new devices for new change of use tenant remodel. devices installed include sprinkler monitoring devices kitchen hood tie in notification devices throughout the restaurant and duct detector monitoring. reference b.p. altc2426309 - (22) devices
Valuation:
N/A
Permit #:
FALRC2431506
Status:
complete
Fee:
$472
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2025-10-06
Removal permit - removing 2 clean agent systems no longer required - rooms are not longer have servers in them. existing preaction suppression sytem will remain in the 2 rooms covering this space
Valuation:
N/A
Permit #:
FALRC2536713
Status:
plancheck
Fee:
$407
Permit Type:
N/A
Building Type:
N/A
Fire suppression | commercial
2025-10-31
8671 sancus blvd reference building permit #altc2510287 alteration to existing fire sprinkler system to addition and relocate 10 sprinklers for ice cream parlor cafe tenant space renovations
Valuation:
N/A
Permit #:
FSUPC2523170
Status:
complete
Fee:
$425
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2023-03-10
Alter existing fire alarm system for 888 apartments by installing new faap per plans. future fire alarm permit to be pulled to address damage from fire. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided... see more
Valuation:
N/A
Permit #:
FALRC2237414
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Fire alarm | commercial
2023-04-14
Alter existing fire alarm system for columbus public schools ecot center by installing new duct detector per plans. stand alone permit. section 901.7 of the ohio fire code requires the fire code official to be notified of any impairment of the fire protection system(s) and the building shall either be evacuated or an approved fire watch be provided until the system(s) have been return... see more
Valuation:
N/A
Permit #:
FALRC2306827
Status:
complete
Fee:
$300
Permit Type:
N/A
Building Type:
N/A
Fire suppression | commercial
2023-06-14
7400 huntington park drive 111 sprinklers reference building permit #addc2226849 alteration to existing fire sprinkler system to addition portion of sprinkler system to new addition for pinnacle treatment center including newly added portion of dry system and wet system sprinkler system: existing modified nfpa13 (building addition) hazard class: light standpipe system: n/a demand at b... see more
Valuation:
N/A
Permit #:
FSUPC2304001
Status:
complete
Fee:
$798
Permit Type:
N/A
Building Type:
N/A
Fire suppression | commercial
2025-06-02
2620 bethel rd reference building permit #altc2426309 alteration to existing fire sprinkler system to addition and relocate 77 sprinklers for new restaurant tenant. antifreeze loop installed
Valuation:
N/A
Permit #:
FSUPC2431514
Status:
complete
Fee:
$593
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 010844
119
BZ Score
$7.8K
Avg Project
-
Projects
License not required
121
BZ Score
$500
Avg Project
-
Projects
License # 9420
131
BZ Score
$10K
Avg Project
-
Projects

Epro Services Reviews

BuildZoom hasn't received any reviews for Epro Services. Click here to be alerted when reviews are posted about them.
Please write a review about Epro Services
1 Rate this plumber
Click stars to rate
2 Provide a detailed review of this plumber.