Share your project details and we'll reach out to
Flagler Roofing, Inc
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Flagler Roofing, Inc at 9333 RAILROAD AVENUE, Oakland, CA 94603, held a Roofer license (#605389) with the California contractors license board with an expiration date of 10-31-2002. We last verified the license was expired on 06-03-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Existing tile on tower portion behind tower and the front right hand side from ridge to gutter edge. remove tile and stack on roof. install layer of modified bitumen membrane base sheet. reapply tile. firezone 2 must comply with chap.16 of the berkeley building code
Existing cap and pan tile on middle portion of house. remove tile. stack on roof. install modified bitumen membrane as base sheet. reapply tile class a. firezone 2 must comply with chap.16 of the berkeley building code
Existing t&g roof on right hand side. sweep up gravel-secure glass base polyglass base sheet. heat bond a layer of polyglass. class a modified to base sheet. firezone 2, must comply with chap. 16 of the berkeley building code
Far right hand side tile portion over garage base sheet. waling deck on left hand side heat bond a layer of mod bit membrane to the existing roof saurface. firezone 2 must comply with chap.16 of the berkeley building code
Over rear t&g roof install glasws base sheet and polyglass base sheet. heat bond layer of polyglass fr-class a mod bitumen membrane to base sheet.firezone2 must comply with chap.16 of the berkeley building code
Sweep up gravel. mechanically fasten with screws and planks. gray polyglass -fr class a modified bitumen membrane on 2 front decks. install a layer of glass base & layer of polyglass base sheet. heat bond layer of polyglass-fr class a modified bitumen to base sheet. firezone 2 must comply with chap.16 of the berkeley building code
Tear off existing. install modified bitumen membrane underlayment. re-apply tile. tear off all tar and gravel roofs. secure layer of base sheet. secure layer of smooth modified bitumen membrane. heat bond layer of polyglass-fr class a modified bitumen membrane to the smooth surface modified firezone 2 must comply with chap.16 of the berkeley building code
Front gable of house only. tear off existing roofing matl. install plywood over existing spaced sheathing boards. sep- arate one layer of 30# felt. apply 30yr composition shingles. class a system firezone 2 must comply with chap.16 of the berkeley building code permit closed 2-4-00. one hour inspection fee for final. sbb
Firezone 2 must comply with chap.16 of the berkeley building code. back of house-re-roof w/layer of glas base layer polyglass base layer of polyglass modified. front of house-35sq tile res- toration. remove existing tile layer of polyglass modified replace tile
Overlay back 1/2 of building with layer of polyglass bitumen. overlay roof on post office w/foam roof layer of poly- glass base layer of polyglass bitumen. overlay left side of post office w/foam roof and coat roof with sunbrite alumin- um coating
Permit closed 7-24-98 sbb existing tar and gravel roof-left hand side tear off all. install tapering system. secure layer of glass base and ployglass base. heat bond layer of polyglass-fr class a modified bitumen membrane to base sheet. firezone 2 must comply with chap.16 of the berkeley building code
Firezone 2 must comply with chap.16 of the berkeley building code. one lower portion behind the front one story portion. secure layer of glass base & layer of polyglass base sheet. heat bond a layer of polyglass-fr class a modified bitumen membrane to base sheet
On garage only - tear off existing roofing matl. on less pitched portion only-in- stall 1/2 plywood with polygoass mod- fied bitumen. polyglass base sheet. in- stall meeker premium select heavy shakes firezone 2 must comply with chap.16 of the berkeley building code
Existing slate on rear bell area. remove slate and set aside. install layer of modified bitumen membrane as base sheet reapply slate. firezone 2 must comply with chap.16 of the berkeley building code permit closed 5-4-98 refund approved sbb
Garage only. scoop up gravel. secure layer of glass base and one layer of polyglass base sheet. heat bond layer of of polyglass-fr class a modified base sheet. reapply gravel. firezone 2 must comply with chap.16 of the berkeley building code
One story eyebrow-remove tile. set aside install modified bitumen membrane as base sheet reapply tile. class a firezone 2 must comply with chap.16 of the berkeley building code
Remove tile stack on roof. install layer of mod bitumen membrane. radpply tile.l install new aluminum gutters firezone 2 must comply with chap.16 of the berkeley building code
Tile roof restoration: remove (e) tile, secure layer polyglass diamondback mod. bitumen membrane, class a. permit closed-other contractor did the work under 02-5084 -marg
Firezone 2 must comply with chap.16 of the berkeley building code. tear off all existing. secura a layer of glass base sheet and a layer of polyglass base sheet. heat bond a layer of polyglass fr class a modified to base sheet
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Flagler Roofing, Inc at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.
Inactive License
License #
267876
Status
Inactive
State
California
Type
Roofing
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Flagler Roofing, Inc at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.