Tear off (e) torch down roof. new sheathing as needed. 1 layer 40# felt. (n) gaf torch down. total of 39 squares. flat pitch ***crrc # 0676-0025d; icc-esr-1274*** ***manufacturer’s installation spec sheets to be onsite *** ***cool roof compliance is required in climate zone 6 for roof slopes less than 2:12***
***bldg d unit 11 12 18-21*** tear off (e) comparable shingles. (n) sheathing as needed. (n) 1 layer of synthetic underlayment. (n) owens corning cool shingles. total of 54 squares. slope 5:12 ***crrc 0890-0013*** ***manufacturer’s installation spec sheets to be onsite ***
***bldg d unit 14-17*** tear off (e) comparable shingles. (n) sheathing as needed. (n) 1 layer of synthetic underlayment. (n) owens corning cool shingles. total of 40 squares. slope 5:12 ***crrc 0890-0013*** ***manufacturer’s installation spec sheets to be onsite ***
***bldg d unit 1-6*** tear off (e) comparable shingles. (n) sheathing as needed. (n) 1 layer of synthetic underlayment. (n) owens corning cool shingles. total of 54 squares. slope 5:12 ***crrc 0890-0013*** ***manufacturer’s installation spec sheets to be onsite ***
***bldg d unit 7 - 10*** tear off (e) comparable shingles. (n) sheathing as needed. (n) 1 layer of synthetic underlayment. (n) owens corning cool shingles. total of 40 squares. slope 5:12 ***crrc 0890-0013*** ***manufacturer’s installation spec sheets to be onsite ***
Tear off (e) comparable new sheathing as needed (n) 1 layer 30# felt underlayment. (n) owens corning shingles 64 squares slope 4:12 -- building c 1-6 ***manufacturer’s installation spec sheets to be onsite *** ***cool roof compliance is required in climate zone 6 for roof slopes less than 2:12**
Tear off (e) comparable new sheathing as needed (n) 1 layer 30# felt underlayment. (n) owens corning shingles 64 squares slope 4:12 -- building c 7-10 ***manufacturer’s installation spec sheets to be onsite *** ***cool roof compliance is required in climate zone 6 for roof slopes less than 2:12**
Tear off (e) comparable new sheathing as needed (n) 1 layer 30# felt underlayment. (n) owens corning shingles 64 squares slope 4:12 -- building c 14-17 ***manufacturer’s installation spec sheets to be onsite *** ***cool roof compliance is required in climate zone 6 for roof slopes less than 2:12**
Tear off (e) flat torch & woodshake. new sheathing 1/2 osb. (n) 1 layer of 30 lbs felt (n) 40 yr owens corning (16 sqs) & gaf built up (8 sqs). total of 24 squares. slope 5:12 ***manufacturer’s installation spec sheets to be onsite *** ***cool roof compliance is required in climate zone 6 for roof slopes less than 2:12***
Re-roof with class a or b roof covering material weighing less than 6 pounds per sq. ft. over existing solid sheathing 25 squares. class a roof covering is required within very high fire hazard severity zone (vhfhsz). for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required... see more
Tear off (e) comparable shingles. no new sheathing. (n) 1 layer of 30lbs felt (n) owens corning comparable. total of 26 squares. slope 5:12; crrc 1372/2453-01 ***manufacturer’s installation spec sheets to be onsite *** ***cool roof compliance is required in climate zone 6 for roof slopes less than 2:12***
Tear off (e) comparable shingles. no new sheathing. (n) 1 layer of 30lbs felt (n) owens corning comparable. total of 22 squares. slope 5:12; crrc 1372/2453-01 ***manufacturer’s installation spec sheets to be onsite *** ***cool roof compliance is required in climate zone 6 for roof slopes less than 2:12***
Tear off (e) comparable shingles. new sheathing as needed. (n) 1 layer of synthetic (n) owens corning shingles. total of 40 squares. slope 5:12 ***manufacturer’s installation spec sheets to be onsite *** (building b units 11-12 18-21)
Tear off (e) comparable shingles. new sheathing as needed. (n) 1 layer of synthetic (n) owens corning shingles. total of 54 squares. slope 5:12 ***manufacturer’s installation spec sheets to be onsite *** (building a units 11-12 & 18-21)
Tear off (e) comparable shingles. new sheathing as needed. (n) 1 layer of synthetic (n) owens corning shingles. total of 40 squares. slope 5:12 ***manufacturer’s installation spec sheets to be onsite *** (building b units 14-17)