We'll help you find the right contractor.

Share your project details and we'll reach out to Macdonald-miller Facility Soluti so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >
M

Location and Projects

Address
5711 SW HOOD, Portland, OR, 97230
Use our bidding system to request a quote

Macdonald-miller Facility Soluti Construction

MacDonald-Miller Facility Solutions brings over three decades of mechanical contracting experience to commercial and institutional projects in Portland, Oregon, and throughout the Pacific Northwest. The company specializes in the design, installation, and ongoing maintenance of complex HVAC, plumbing, and building automation systems. Their project portfolio includes hospitals and facilities with critical infrastructure, focusing on environments that require consistent, reliable system performance. MacDonald-Miller manages all phases of mechanical construction, from in-house prefabrication to field installation and commissioning. Their team addresses challenging factors such as aging infrastructure, evolving building codes, and tight construction timelines. In addition to new system installations, they provide services in controls integration, sustainable building solutions, and long-term facility support. With a regional presence established for over 35 years, MacDonald-Miller has built long-standing relationships with facility managers, property owners, and organizations that rely on dependable system operation year-round.

Macdonald-miller Facility Soluti Services

Start a project today:

Macdonald-miller Facility Soluti Contact Information

Phone: (503) 230-8991 Edit
Address: 5711 SW HOOD, Portland, OR 97230 Edit

Macdonald-miller Facility Soluti Portland

Quality

103
90th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Macdonald-miller Facility Soluti has a BuildZoom score of 103, which places them above 90% of 62,733 contractors in Oregon.

Activity

41 projects
2025
79 projects
2024
82 projects
2023
Our building permit records indicate that Macdonald-miller Facility Soluti has worked on at least 202.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

34 projects
Home Additions
12 projects
Commercial Renovations
12 projects
New Constructions
5 projects
Kitchen remodels
Analyzing permits over the last 4 years shows that Macdonald-miller Facility Soluti mostly works on home addition and new construction projects.

Pricing

7 projects
< $5k
26 projects
$5k-$20k
22 projects
$20k-$50k
16 projects
$50k-$100k
13 projects
$100k-$250k
11 projects
$250k-$500k
6 projects
$500k-$1mil
6 projects
$1mil+
Value Not Public: 112.0 projects
The typical size of their permits is approximately $51,906. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Building Permits by Macdonald-miller Facility Soluti

Sort by: Notable Notable | Date Date | Job Value Job Value
Mechanical permit
2025-03-24
The second phase of the willamette university campus heating decentralization project. the overall phase 2 will install two boiler plants to replace the remaining steam boiler system load. this permit scope is limited to the collins science center building demolition remove existing fluid coolers ct-1 2 and associated connection piping and accessories. dispose off site. remove existin... see more
Valuation:
$875,000
Permit #:
25 106644 00 M
Status:
plancheck
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical permit
2025-03-31
Remove: two existing steam converters one steam heating coil three heating hot water pumps 2 expansion tanks 2 air separators 17 steam convectors and associated piping replace with: one hydonic heating coil fifteen hydronic convectors and associated piping
Valuation:
$263,788
Permit #:
25 107144 00 M
Status:
issued
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical permit
2025-03-28
Demolition: remove existing steam heating coil and associated steam piping and accessories. new work: install new heat hot water coil. install new heating hot water piping from basement to mechanical room. install new ductwork connections to new coil. floor: 3
Valuation:
$135,000
Permit #:
25 107119 00 M
Status:
issued
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical permit
2024-06-20
Shut down and lockout chiller and all associated equipment including pumps. drain chilled water system. reclaim refrigerant and oil from chiller. disconnect water piping and structural tie-downs to prepare equipment for removal. disconnect existing 120v circuit save for reconnection. provide and install (1x) new 275-ton york air-cooled screw chiller model yvaa-0275.crane to lift equip... see more
Valuation:
$345,000
Permit #:
24 113464 00 M
Status:
issued
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical permit
2024-05-09
Scope of work: demolition of two existing steam to water converters condensate receiver and all associated piping in the boiler room. install new boilers and associated accessories. install all new piping in boiler room to connect all equipment and existing building piping. install new controls for new equipment. install new piping to connect to lausanne hall building
Valuation:
$1,200,000
Permit #:
24 110295 00 M
Status:
final
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical permit
2024-05-06
Install new secondary pumps serving heat exchangers. install new tertiary pumps serving building heating water systems. install new plate heat exchangers serving building heating water systems. install new expansion tanks and air separators serving building heat water systems. install all new piping to connect all equipment. install new controls for new equipment
Valuation:
$500,000
Permit #:
24 109976 00 M
Status:
final
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical permit
2024-01-23
Extend natural gas piping from new nw natural meter at each building to serve new boiler and water heaters. install new boilers and associated accessories. install new primary pumps serving boilers. install new secondary pumps serving heat exchangers. install new tertiary pumps serving building heating water systems. install new plate heat exchangers serving building heating water sys... see more
Valuation:
$2,000,000
Permit #:
24 102421 00 M
Status:
issued
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Commercial mechanical
2024-04-17
Rooftop make-up air unit. rooftop heat pump. energy recovery ventilators. ductless split systems. electric unit heaters. exhaust is provided by rooftop exhaust fans. mua-1—10, 000cfm make-up air remote terminal unit w heat recovery dx heat pump and roof curb. ef-1—15, 000cfm exhaust fan w roof curb motorized damper and tstat. ef-2—15, 000cfm exhaust fan w roof curb motorized damper an... see more
Valuation:
$336,029
Permit #:
877-24-000040-MECH
Status:
issued
Fee:
$1,144
Permit Type:
New
Building Type:
N/A
Commercial plumbing
2024-08-08
Plumbing systems - process waster sanitary waste vent domestic cold/hot/tempered water rainwater/overflow drains emergency shower catch basin (buried in slab) submersible sump pumps serving safety shower. plumbing fixtures - water closet lavatory kitchen sink janitor sink (mop basin) (3) emergency shower/eyewash stations floor drains trap primers for floor drains floor sinks ada two l... see more
Valuation:
$274,223
Permit #:
877-24-000031-PLM
Status:
issued
Fee:
$2,051
Permit Type:
New
Building Type:
N/A
Plumbing permit
2025-03-24
Install bypass line between the caf heat exchangers and the tower heat exchangers #1 and #2 the domestic water supply and the domestic water return. includes connections at the 140f dhw line the 120f dhw line and the 120f dhr line per the drawing detail. this work is to be performed after-hours during a planned shut-down coordinated with the hospital. new bypass lines to utilize exist... see more
Valuation:
N/A
Permit #:
25 106664 00 P
Status:
issued
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical (commercial) - mechanical commercial (insp workflow)
2024-12-12
Installationof (2) cleanrooms and (1) ante room. (1) new roof mounted chiller (2200 lbs) (2) roofmounted ef's (250 lbs each) (1) fan coil unit located in the ceiling space (1750 lbs) ductwork and piping modifications and additions
Valuation:
$622,240
Permit #:
MECHC-22-05728
Status:
complete
Fee:
$10,276
Permit Type:
N/A
Building Type:
N/A
Commercial medical gas
2025-03-31
Modify & extend med gas piping to accommodate a new or boom. also adding (4) wall outlets to or4. floor: 2 | suite: 200 *added electrical plan reviewer to this permit to review. electrical to be applied for separately spc 2/26/25
Valuation:
N/A
Permit #:
PLMBC-25-00959
Status:
complete
Fee:
$518
Permit Type:
N/A
Building Type:
N/A
Commercial mechanical
2023-01-03
Relocating 2 existing vav boxes and installing an vav additional box. installing new flex and grilles in the project space. reworking small areas of ductwork to accommodate the walls being shifted.- extending a 1 chilled water supply and return to cool a new piece of equipment (supplied and installed by others) (wvmc - cancer center expansion - see 569-22-000225-str for building permit)
Valuation:
$228,829
Permit #:
569-22-001228-MECH
Status:
issued
Fee:
$2,471
Permit Type:
Alteration
Building Type:
N/A
Mechanical permit
2023-12-30
Demolition: - remove boiler b-1 and all associated near-boiler steam and condensate piping and dispose off site. - cut and cap steam and pumped condensate piping serving boiler b-1 at the respective header connections. header system piping to remain. - remove near-boiler natural gas piping. new work - install two new shutoff valves in natural gas supply piping to existing boilers. - n... see more
Valuation:
$300,000
Permit #:
23 124900 00 M
Status:
expired
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Mechanical permit
2023-03-23
Demolish and remove existing cooling towers ct-1 and ct-2 and piping connections on roof of building c. overhead netting to be removed by others. provide and install (1x) new evapco at 212-3m24 cooling tower 2 cells 550-tons each. existing steel i-beam platform with spring isolators to be reutilized. install to be performed on a saturday. tie in new towers to existing building condens... see more
Valuation:
$292,000
Permit #:
23 106838 00 M
Status:
final
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
*eplans* hvac controls upgrade for office and lab spaces. new controllers actuators and sensors for better control and economic effects of the buildings hvac system. per osu letter applicant to pay fees. macdonald miller facility solutions llc license/registration no: c1584 expiration date: 07/01/2026 signing person information wesley n foley: 6407s
Valuation:
N/A
Permit #:
ELP25-00163
Status:
issued
Fee:
$302
Permit Type:
Commercial
Building Type:
N/A
Commercial mechanical
2024-07-19
Hvac piping - demolish existing undersized piping back to the main header. install new piping to the size stated in the drawings (exhibit g provided by mke &associates inc.) from main header to the units on the following: ahu-1 ahu-2 ahu-3 ahu-4. demolish and install new piping per plans for the boiler header repipe to heating coils insulation high and low point vents and drains. prov... see more
Valuation:
$100,000
Permit #:
489-24-000702-MECH
Status:
final
Fee:
$696
Permit Type:
Alteration
Building Type:
N/A
Plumbing permit
2025-03-28
Extend new sanitary drain lateral to serve new cooling tower ct-1 sump drain. primed p-trap at riser to area drain. concrete remove and replace as necessay. trench and backfill as necessary
Valuation:
N/A
Permit #:
25 107116 00 P
Status:
issued
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Commercial mechanical
2022-10-20
Fuel oil system: ast-1 above ground diesel storage tank (12, 000 gallon capacity) and accessories. dt-1, 2 – day tanks fuel piping and accessories. fmcp-1 fuel monitoring control panel. fps-1 fuel polishing system. ldp-1 & lds-1 leak detection and tank monitoring system. rffp1- remote fuel fill panel. sp-1 submersible pump (diesel). spcb-1 submersible pump control box. ts-1 ts-2 - tra... see more
Valuation:
$777,478
Permit #:
489-22-000810-MECH
Status:
issued
Fee:
$2,589
Permit Type:
Alteration
Building Type:
N/A
Plumbing (commercial) - plumbing interior (insp workflow)
2022-03-16
Demolish existing floor drain in vacated rm#2119 remove & reinstall sink. demolish and rework rough in piping for sink ice maker and floor drain in recovery rm#2059. remove existing scrub sink outside of or# 6 and modify plumbing for new scrub sink. modify and reroute existing storm drain piping in or#6 to accommodate new overhead boom
Valuation:
$1,500,000
Permit #:
PLMBC-22-01528
Status:
issued
Fee:
$438
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 173347
134
BZ Score
-
Avg Project
-
Projects
License # 216749
137
BZ Score
$750K
Avg Project
-
Projects
License # 203089
153
BZ Score
$101K
Avg Project
-
Projects

Macdonald-miller Facility Soluti Reviews

BuildZoom hasn't received any reviews for Macdonald-miller Facility Soluti. Click here to be alerted when reviews are posted about them.
Please write a review about Macdonald-miller Facility Soluti
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.