Updated: Apr 04, 2026
Location and Projects
Address
3072 350th ave, Sandstone, MN, 55072
Use our bidding system to
request a quote
Maser Electric
Maser Electric, 3072 350th Ave, Sandstone, MN (Owned by: Maser Matthew K) holds a Electrical license and 3 other licenses according to the Minnesota license board.
Their BuildZoom score of 107 ranks in the top 6% of 77,973 Minnesota licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Maser Electric, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Maser Electric Contact Information
Phone Number: (320) 280-0783
Edit
Address: 3072 350th ave, Sandstone, MN 55072
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Maser Electric Reviews
5 out of 5 stars, based on
1
review
-
By Jodi H.June 13, 2025Move outside circuit breaker box, wire pole building, add additional outlets in our house.$7,800
This is a sample of this contractor's permits. Click here to access their complete permit history.
Upgrade service on yard pole to new 200 amp meter main overhead service with one gfci outlet below service equipment. also new underground power supply to existing barn use strictly for storage shed. install breaker panel in barn with gfci outlet and one light
Valuation:
N/A
Permit #:
ELE2505-05679
Status:
final
Fee:
$89
Permit Type:
One-family dwelling
Building Type:
N/A
Installed and wired 100 amp breaker panel in new shed north of house. installed new 90 amp underground power supply from house to shed panel. also installed and wired one gfci outlet at shed panel and one pull chain light at shed panel only. homeowner may do all other shed wiring
Valuation:
N/A
Permit #:
ELE2501-01370
Status:
final
Fee:
$48
Permit Type:
One-family dwelling
Building Type:
N/A
Installed 200 amp meter main on west exterior of house. replaced fusebox in hall with circuit breaker panel and reconnected existing circuits. replaced existing sub panel in basement with new 20 circuit breaker panel. reconnected existing circuits
Valuation:
N/A
Permit #:
ELE2503-00673
Status:
final
Fee:
$156
Permit Type:
One-family dwelling
Building Type:
N/A
Electric heat- dual fuel. wired all existing electric heat other than the crawl space onto dual fuel control and metering. also installed new fan forced wall heater in entryway and new toe kick space heater in kitchen island
Valuation:
N/A
Permit #:
ELE2503-12981
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Installed and wired 100amp site panel on post behind double wide wired 100amp feeder to double wide. wired septic mound well pump central air conditioning unit one gfci outlet on post panel. one surge protected. device on post panel. one 50-30-20 rv box on yard light pole-gfci protected outlets in rv box
Valuation:
N/A
Permit #:
ELE2412-00141
Status:
final
Fee:
$136
Permit Type:
One-family dwelling
Building Type:
N/A
New 200amp meter main service on utility pole. reconnect the existing trailer house and also new power supply to the existing trailer house. also a new power supply to the existing machine shed replacing overhead wire with underground
Valuation:
N/A
Permit #:
ELE2505-07761
Status:
final
Fee:
$171
Permit Type:
One-family dwelling
Building Type:
N/A
Installed new underground power supply to detached garage 120/240 volt power supply from house service panel. also reconnected existing power to pole shed into new exterior panel on garage. reconnected 2 existing garage circuits
Valuation:
N/A
Permit #:
ELE2407-10152
Status:
final
Fee:
$54
Permit Type:
One-family dwelling
Building Type:
N/A
New lighting. installed two new led strip lights in east voting room. extended existing circuit. also installed new exterior led flood light on west gable of building for illuminating flag. one new circuit. mc cable above dropped ceiling
Valuation:
N/A
Permit #:
ELE2412-00161
Status:
final
Fee:
$36
Permit Type:
Non-dwelling
Building Type:
N/A
Installed new 100amp outdoor service panel on yard pole with existing overhead service. also installed surge protective device in panel and one midwest 50 30 20 rv panel on pole
Valuation:
N/A
Permit #:
ELE2503-12283
Status:
final
Fee:
$66
Permit Type:
One-family dwelling
Building Type:
N/A
Wired and installed 40amp 120/240 power supply from house service panel to exterior sauna. installed exterior electric panel on exterior of sauna. wired 40 amp circuit to sauna. heater installed and wired one gfci outlet in sauna
Valuation:
N/A
Permit #:
ELE2412-08049
Status:
issued
Fee:
$48
Permit Type:
One-family dwelling
Building Type:
N/A
Wire new garage. 100 amp power supply from meter main and complete wiring of new garage. also installed generator inter lock on meter main with 50 amp power inlet
Valuation:
N/A
Permit #:
ELE2410-01910
Status:
final
Fee:
$90
Permit Type:
One-family dwelling
Building Type:
N/A
Install and wire new storage electric heat service parallel 4/0 ud from transformer to 320 meter 250 kcmil to panels. wiring of existing storage heaters and new heaters. total potential heat load- 57.6 k.w
Valuation:
N/A
Permit #:
ELE2412-08048
Status:
issued
Fee:
$108
Permit Type:
Non-dwelling
Building Type:
N/A
Remodel of exterior. install new recess type led lighting in south and west soffit areas of existing building. primarily fishing wires. one new circuit
Valuation:
N/A
Permit #:
ELE2412-08576
Status:
final
Fee:
$71
Permit Type:
Non-dwelling
Building Type:
N/A
Installed and wire 120/240 volt underground power supply from house panel to garage panel. also installed and wired one gfci outlet below garage panel one exterior service door light and 2 switches at service door only. homeowner states that he will do all other wiring
Valuation:
N/A
Permit #:
ELE2411-08024
Status:
final
Fee:
$48
Permit Type:
One-family dwelling
Building Type:
N/A
Reaplce damaged overhaead service conductors with new 100 amp underground and install service disconnect on exterior of house refed house panel with ser cable all other wiring existing also from outdoor disconnect. new power supply to storage shed installed breaker panel in shed with one light by panel and one exterior light at service door and one gfci outlet by panel
Valuation:
N/A
Permit #:
ELE2411-02193
Status:
final
Fee:
$118
Permit Type:
One-family dwelling
Building Type:
N/A
Install 100 amp service disconnect on power pole below existing 100 amp meter loop on pole. reconnect double gfci outlet box on pole. install 100 amp underground power supply to existing dwelling and install install electric panel in bedroom install one gfci outlet below panel on arc fault 20 amp circuit also. reconnected 3 existing circuits that were previously powering dwelling to n... see more
Valuation:
N/A
Permit #:
ELE2407-00659
Status:
final
Fee:
$105
Permit Type:
One-family dwelling
Building Type:
N/A
Replaced 2 existing sub-panels with one 30 circuit sub-panel and reconnect existing circuit that were in 2 sub-panels into new 30 circuits sub-panel. also wired 3 new gfci protected post outlets at pond location west exterior of house gfci protected by circuit circuit breakers in sub panel. also installed surge productive device in new sub panel
Valuation:
N/A
Permit #:
ELE2407-05515
Status:
expired
Fee:
$80
Permit Type:
One-family dwelling
Building Type:
N/A
Wired one new 240 volt 20amp circuit to air conditioning disconnect for mini-split on north exterior of house. installed 15 amp fuses in air conditioning disconnect as per nameplate. replaced existing outdoor outlet by mini-split with gfci outlet and in use cover as per code
Valuation:
N/A
Permit #:
ELE2406-04466
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Wired new 240 volt 15 amp circuit to new control air conditioning union on south exterior of house. replaced existing exterior outlet by air conditioning unit to gfci receptacle outlet. also installed 50 amp 4 wire range outlet below garage sub-panel outlet is gfci protected by gfci circuit breaker
Valuation:
N/A
Permit #:
ELE2406-04458
Status:
final
Fee:
$36
Permit Type:
One-family dwelling
Building Type:
N/A
Installed and wired underground 30amp 120/240volt tap power supply from 50 amp on meter pedestal to 30 amp main breaker outdoor panel on bunk house. also installed on gfci outdoor outlet by outdoor electric panel. all other wiring by property owner
Valuation:
N/A
Permit #:
ELE2406-04453
Status:
final
Fee:
$42
Permit Type:
One-family dwelling
Building Type:
N/A
Similar Contractors See more
111
BZ Score
$2K
Avg Project
-
Projects
License # EA002027
North Branch, MN
111
BZ Score
$750
Avg Project
-
Projects
111
BZ Score
$1.3K
Avg Project
-
Projects
Recent Buildzoom Projects
Let us find you an electrician in your area today
We'll search our vast network of Electricians and connect
you with one that meets your needs today.
Verified License
BuildZoom confirmed this contractor's license
Maser Electric License info
Verified License
| License # | AM005273 |
| Status | Active |
| State | Minnesota |
| Type | Electrical |
| Business Type | Individual Proprietorship |
- BuildZoom verified this license was active as of March 2026.
Verify this license's status for Maser Electric at the Minnesota Department of Labor & Industry.
This is a sample of licensing data; click here to access a complete history.
Verified License
| License # | EA004523 |
| Status | Active |
| State | Minnesota |
| Type | Electrical |
| Business Type | Individual Proprietorship |
- BuildZoom verified this license was active as of April 2026.
Verify this license's status for Maser Electric at the Minnesota Department of Labor & Industry.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | 20632717 |
| Status | Inactive |
| State | Minnesota |
| Type | Independent Contractor |
| Business Type | Individual Proprietorship |
- According to the Minnesota Department of Labor & Industry, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Maser Electric at the Minnesota Department of Labor & Industry.
This is a sample of licensing data; click here to access a complete history.
Inactive License
| License # | CA04523 |
| Status | Inactive |
| State | Minnesota |
| Type | Class A Electrical Contractor |
| Business Type | Individual Proprietorship |
- According to the Minnesota Department of Labor & Industry, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Maser Electric at the Minnesota Department of Labor & Industry.
This is a sample of licensing data; click here to access a complete history.
107
BuildZoom Score
747
Permits
- Building permit records show that Maser Electric has worked on 747 permitted projects.
Maser Electric Employees
MK
Maser Matthew K
Owner
MK
Maser Matthew Ken
Owner
MK
Maser, Matthew K
Owner
MM
Matthew K. Maser
We had a pole building wired for electric, an outside circuit breaker box moved, and additional outlets added in our house. Maser Electric provided a very positive experience. Quality work was completed at reasonable rates. Matt Maser was very friendly and a pleasure to work with!