Mighty Mo Electric

We are a small residential and light commerical electrical contracting company. We do remodeling, repair, replacement, and upgrade work. We work in Philadelphia and the townships bordering Philadelphia.

From BuildZoom: Mighty Mo Electric, 6 Pelham Rd, Philadelphia, PA holds a Renovation license and 3 other licenses according to the Environmental Protection Agency license board.

Their BuildZoom score of 107 ranks in the top 6% of 125,106 Pennsylvania licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Mighty Mo Electric, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Mighty Mo Electric Services

Start a project today:

Mighty Mo Electric Contact Information

Phone: (267) 307-2121
Address: 6 Pelham Rd, Philadelphia, PA 19119

Mighty Mo Electric Reviews
5 out of 5 stars, based on 1 review

  • By Rachel S.
    April 12, 2017
    several projects
    90 days

    Monika is an excellent electrician and she has worked on many of my projects. She is honest and hard-working, and will provide you with the best results. I highly recommend her!

Please write a review about Mighty Mo Electric
1 Rate this electrician
Click stars to rate
2 Provide a detailed review of this electrician.


Building Permits by Mighty Mo Electric

Sort by: Notable Notable | Date Date | Job Value Job Value
Electrical permit
2018-09-24
Service entrance upgrade to 200a. re-wire majority of property with 18- circuits keep existing 100a sub-panel correct bonding. hard-wired interconnected smoke alarms c/o detectors. work in accordance with 2008 nec for a one family building
Valuation:
N/A
Permit #:
907962
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2018-03-01
Re-wire property relocate service from back to front of building. new 200a service. bring property to code: kitchen laundry room bathrooms hardwired interconnected smoke & c/o detectors. in accordance with 2008 nec for a one family building
Valuation:
N/A
Permit #:
854577
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2018-03-01
Re-wire re-introduction of service. new service: 200a. bring property to code including kitchen laundry room bathrooms and hardwired interconnected smoke & co detectors. in accordance with 2008 nec for a one family building
Valuation:
N/A
Permit #:
854570
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2018-05-15
Re-wire property, main panel replacement (15-circuits). bring home to code including kitchen laundry room bathrooms and hardwired interconnected smoke and c/o detectors. per 2008 nec for a one family building
Valuation:
N/A
Permit #:
867412
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2018-06-28
Install 200amp service complete with ground wire throughout outlets, switches, lights, gfci and smoke detectors per 2008 nec (sfd)
Valuation:
N/A
Permit #:
889840
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2017-10-25
Install 42 recessed lights replace outlets w/tamper resistant outlets replace smoke/co's addition gfci receptacles upgrade service to 200a (replacing cable & panel install air conditioning circuit. in accordance with 2008 nec for a one family building
Valuation:
N/A
Permit #:
826374
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2016-05-17
Addition electric oven wiring replace cooktop and exhaust hood addition recessed lights move light fixtures ensuring small appliance lines and all kitchen and bathroom electric are to code. work in accordance with 2008 nec for a one family building
Valuation:
N/A
Permit #:
692104
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2016-08-16
Install (4) 120v hard-wired interconnected smoke alarms (4) hard-wired interconnected co/smoke alarms on a dedicated circuit. remodel kitchen and bathroom. replace any remaining knob-and-tube circuits on all floors as per 2008 nec. (south)
Valuation:
N/A
Permit #:
714374
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2017-12-15
Rewire 1st floor carriage house replace service entrance addition sub-panel- 2nd floor wire kitchen and bathroom living space outlets & lights hardwired interconn smoke & c/o detectors. per 2008 nec for a one family building
Valuation:
N/A
Permit #:
833692
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2017-04-21
Rewire property except incoming service which will remain as is. entire house to be brought to code and includes 2.5 bathrooms laundry room and kitchen. in accordance with 2008 nec for a one family building
Valuation:
N/A
Permit #:
776799
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2012-07-31
Install 9-2'x 4 lay-in flourescent fixtures & 8 recepts, lights wil be fed by 2-20a feeds recepts will be fed by 2-20a feeds wire is #12 awg m.c. cable w equip ground as per 2008 nec(strip mall space)
Valuation:
N/A
Permit #:
419340
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2019-03-19
Re-wire a one family dwelling as per 2008 nec
Valuation:
N/A
Permit #:
950746
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2013-01-15
Converting a 100amp service to a 200amp service per 2008 nec (sfd)
Valuation:
N/A
Permit #:
448049
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Electrical permit
2015-07-27
To change end box from an 18x18x4 to a 24x24x6 enclosure fro code sizing and change a 3 rmc nipple to a 4 rmc nipple per peco request. in accordance with 2008 nec
Valuation:
N/A
Permit #:
627357
Status:
expired
Fee:
N/A
Permit Type:
N/A
Building Type: