Native Technology Solutions Inc, Chandler, AZ (Employees: Clarice Sue Chiago Jones, Daniel Joseph Reynolds, and Darrell Wayne Yazzie) holds a Specialty Dual license and 1 other license according to the Arizona license board.
Their BuildZoom score of 0 does not rank in the top 50% of Arizona contractors.
Their license was verified as active when we last checked. If you are thinking of hiring Native Technology Solutions Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
**tcp page 13**heading south on the west side of park avenue and continuing west on the north side of valencia road install aerial and underground 288 count fiber and conduit. strand from pole to pole; building riser up pole and place anchor; place sidewalk down-guy; place locate wire; install junction box and place slack in vault; place locate marking post; directional bore; install ... see more
Beginning on the north side of valencia avenue and crossing to the south side of valencia avenue just west of commerce court install aerial and underground fiber. place 288 fiber and conduit and locate wire. directional bore; install junction box and place slack in vault; place locate marking post. removal and replacement of concrete. (permit 2 of 7) plan sheets 48-50
Install aerial and underground fiber on the south side of valencia road. place conduit and 288 count fiber; place locate wire; directional bore; install junction box; place fiber slack in vault and place locate marking post. removal and replacement of concrete. (permit 1 of 7) plan sheets 45-47 10/2/25- renewal request for 90 days as of 10/5/25
Place conduit and fiber in conduit directional boring; building rise up to pole place anchor and down-guy; place locate wire; strand from pole to pole; building rise up to pole; place anchor and sidewalk down-guy; install on each pole install ground wire assembly; removal and replacement of concrete. (permit 6 of 7) plan sheets 60-62
Place conduit fiber and locate wire. directional boring a hole.build rise up to pole place anchor and down-guy. install one utility pole: install ground wire assembly; remocal and replacement of concrete. (permit 3 of 7) plan sheets 51-53
Install 3 hdpe 1.25 conduit heading west along valencia road. place 288 fiber in conduit with locate wire. direction bore install junction box removal and replacement of concrete. starting at 4850 s park ave through fremont av & pennsylvania st. (permit 7 of 7) plan sheets 63-65
Install 3 hdpe 1.25 conduit heading west along valencia road (from s missiondale rd to s park ave). place 288 fiber in conduit with locate wire. directiong bore install junction box removal and replacement of concrete
Install 3 hdpe 1.25 conduit heading west along valencia road. place 288 fiber in conduit with locate wire. directiong bore install junction box removal and replacement of concrete
Install 3 hdpe 1.25 conduit heading west along valencia road (at s. headly rd). place 288 fiber in conduit with locate wire. directiong bore install junction box removal and replacement of concrete
Install 3 hdpe 1.25 conduit heading north along park ave. place 288 fiber in conduit with locate wire. directiong bore install junction box removal and replacement of concrete
Install 3 hdpe 1.25 conduit heading north along park ave. place 288 fiber in conduit with locate wire. directiong bore install junction box removal and replacement of concrete. starting from 6302 s park av through park/drexel rd. (permit 5 of 7) plan sheets 57-59
Alluvion is installing underground conduit and fiber optic cable from a zayo tie-in junction box on the nec of 56th st and chandler blvd to a grti tie-in junction box on the swc of pecos rd and 56th st. total installation distance is 11, 100 feet
Alluvion is installing underground conduit and fiber optic cable from an alluvion junction box on the nwc of price rd and queen creek rd to a zayo tie-in junction box on the swc of price rd and wells fargo pl. total installation distance is 1300 feet
To get fiber optics routed from tortosa down murphy road to farrel road for new high school internet feed. first section out of tortosa southeast will be underground to first ed-3 pole on murphy
To bore from an existing vault in the middle of the drive into laquinta off of martin luther king blvd to our conduit next to ed-3's transformer just to the southeast approximately 200 feet