Don't wait to get a Solar Pro

We make finding a solar contractor fast, easy, and commitment-free.

Call now (623) 303-4802
  • Local & Qualified
  • Rapid Connection by Phone
  • Commitment-Free Calls
Is this your business? Claim now >
o

Location and Projects

Address
Phoenix, AZ, 85281
Use our bidding system to request a quote

on Point Renovation Solar Contractor

Their BuildZoom score of 89 does not rank in the top 50% of Arizona contractors.

If you are thinking of hiring on Point Renovation, LLC, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

on Point Renovation, LLC Services

Start a project today:

on Point Renovation, LLC Contact Information

Phone: (623) 294-7083 Edit

on Point Renovation, LLC Phoenix

Quality

89
30th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
on Point Renovation, LLC has a BuildZoom score of 89, which places them above 30% of 71,576 contractors in Arizona.

Activity

127 projects
2025
384 projects
2024
472 projects
2023
Our building permit records indicate that on Point Renovation, LLC has worked on at least 983.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

13 projects
Home Additions
3 projects
Commercial Renovations
894 projects
Solar installations
Analyzing permits over the last 4 years shows that on Point Renovation, LLC mostly works on solar installation and home addition projects.

Pricing

119 projects
< $5k
80 projects
$5k-$20k
59 projects
$20k-$50k
28 projects
$50k-$100k
1 project
$100k-$250k
Value Not Public: 721.0 projects
The typical size of their permits is approximately $9,965. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

on Point Renovation, LLC Reviews
1 out of 5 stars, based on 1 review

  • By Roland I.
    May 17, 2023
    SOLAR PANELS

    in september of 2022 we started the process of choosing and installing a solar panel system on the house.. we chose OnPoint we were told it will be about a 3 month process(verbally not in writing).. we chose a 22kw at about $100k they worked out a financing deal as well. after many months the system was finally installed. there were many electrical inspections revisions and adjustments.. inmay of 2023 finally the system was turned on.. it is producing a respectable 16kw.. 72% of what we agreed and was to be installed.. we looked into it and called the manufacturer SolarEdge.. they told us that the system only has a 16kw invertor and will need additional invertors,(additional cost.. lots of it). contacted OnPoint and they will not get back to us. we also noticed that WE HAVE CRACKED ROOF TILES and SOME ARE CAULEKD some SOLAR PANELS ARE NOT PROPERLLY INSTALLED and aprear TO BE WORPPED CLAMPS ARE NOT IN LINES and PANELS ARE LOOSE..... please DO NOT USE THIS COMPANY
    OnPoint is a joke. AVOID THE PAIN/HEADECHS.. DO NOT CALL OR USE THEIR SERVICES

Please write a review about on Point Renovation, LLC
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.


Building Permits by on Point Renovation, LLC

Sort by: Notable Notable | Date Date | Job Value Job Value
Addenda deferred code modification
2025-02-20
Revise plan has been received updating label to (e) 60a utility air conditioning disconnect switch (1 of 2) on the site plan and three line diagram. update (n) utility air conditioning disconnect switch (2 of 2) in site plan and three line diagram. remove (1 of 3) from the (n) der meter disconnect switch on the site plan
Valuation:
$35,000
Permit #:
PMT24-19024A
Status:
complete
Fee:
$250
Permit Type:
Residential - add...
Building Type:
N/A
Addenda deferred code modification
2025-04-01
Addenda - the modifications for this project are: • moving forward with a new mpu 200a rated 240v • installing a new bi-directional tesla backup switch. • relocating some equipment such as moving the fused disconnect next to the pw3 and installing a new der meter
Valuation:
$25,000
Permit #:
PMT24-19024B
Status:
complete
Fee:
$250
Permit Type:
Residential - add...
Building Type:
N/A
Construction and trades residential
2025-07-02
Derate main breaker from 200a rated to 175a effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code scope of work: derate (e) 200a main breaker to be derated to (n) 175a hillside: no flood plain: no historic: no reviewers:
Valuation:
$5,000
Permit #:
CTR-102502521
Status:
final
Fee:
$372
Permit Type:
Service upgrade -...
Building Type:
Single family
Electrical/mechanical permit
2025-10-10
New photovoltaic roof mounted system - 9.60 kw dc 12.00kw ac1820w liddell dr tucson az85704 derate: (e) 200a main breaker to be derated to(n) 175a to allow backfeed of 50a and rev1: equipment location change 60a disco to be non-fused remove 200a main breaker in critical load panel 200a main breaker in grid boss where critical load panel is connected
Valuation:
N/A
Permit #:
P25BP00347
Status:
final
Fee:
$261
Permit Type:
N/A
Building Type:
N/A
Building revision
2025-06-06
05/16/2025 revision to bld24-2466 revised plans to show the correct wiring per srp powerwall 3 connecting to the top of the meter. revised plans to reverse the polarity on the der meter so that the der is feeding to the line side and the grid is on the load side der meter wired backwards
Valuation:
N/A
Permit #:
BLDREV25-0180
Status:
triage
Fee:
$60
Permit Type:
N/A
Building Type:
N/A
Electrical/mechanical permit
2025-07-09
Photovoltaic roof mount system17 modules-roof mounted - 6.205 kw dc 7.600 kw air conditioning line side tap interconnection at meter socket -p25bp01153 approval-document rev1-sa20250211-6-94-1944-b
Valuation:
N/A
Permit #:
P25BP01153
Status:
final
Fee:
$308
Permit Type:
N/A
Building Type:
N/A
Addenda deferred code modification
2025-09-03
Addenda - the modifications for this project are: - use of eaton b-line meter 011 - doing a regular mpu 225amp rated bus & 200amp main breaker and adding a non-fused disconnect between the powerwall 3 and the production meter
Valuation:
$25,000
Permit #:
PMT25-15678
Status:
applied
Fee:
$120
Permit Type:
Residential - add...
Building Type:
N/A
Construction and trades residential
2024-05-28
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code description of work: (n) 225a mpu this is actually a 200 amp ses changeout for a photovoltaic installation on a separate photovoltaic permit reviewer: glimo contact your electric service provider to verify any additional panel requirements
Valuation:
$53,274
Permit #:
CTR-102404372
Status:
canceled
Fee:
N/A
Permit Type:
Service upgrade -...
Building Type:
Single family
Building revision
2025-02-21
02/10/2025 - revision #1 to bld24-2466 \ clouding per given existing plan changes have been made on pv-1 pv-2 pv-3 pv-4 pv-4.1 pv-6 pv-7 pv-7.1 pv-7.2 pv-8 pv-8.1 pv-9
Valuation:
N/A
Permit #:
BLDREV25-0057
Status:
triage
Fee:
$60
Permit Type:
N/A
Building Type:
N/A
Building permit
2025-06-04
Photovoltaic roof mount system15 modules-roof mounted - 6.075 kw dc 11.500 kw air conditioning. tesla backup switch will be pcs to be 160a
Valuation:
$18,000
Permit #:
BLD25-0609
Status:
complete
Fee:
$150
Permit Type:
N/A
Building Type:
N/A
Residential utility repair permit
2024-07-25
Replacement of 200 amp (or less) electric panel - no plans required. installation shall comply with city of mesa codes and servicing electric utility requirements. do not disconnect utility wires or meters. schedule disconnect/reconnect with the serving utility and obtain utility service requirements specific to your permit. failure to schedule disconnect may result in additional util... see more
Valuation:
N/A
Permit #:
PMT24-13604
Status:
issued
Fee:
$229
Permit Type:
Replacement of 20...
Building Type:
N/A
Residential utility repair permit
2024-08-28
Replacement of 200 amp (or less) electric panel - no plans required. installation shall comply with city of mesa codes and servicing electric utility requirements. do not disconnect utility wires or meters. schedule disconnect/reconnect with the serving utility and obtain utility service requirements specific to your permit. failure to schedule disconnect may result in additional util... see more
Valuation:
N/A
Permit #:
PMT24-13464
Status:
final
Fee:
$229
Permit Type:
Replacement of 20...
Building Type:
N/A
Construction and trades residential
2024-05-28
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code service upgrade per current electrical code reviewer: tdonc (no plans required) contact your electric service provider to verify any additional panel requirements description of work: new msp 200a/200a rated siemens mc4040s1200 solar ready panel
Valuation:
N/A
Permit #:
CTR-102405571
Status:
issued
Fee:
$168
Permit Type:
Service upgrade -...
Building Type:
Single family
Residential utility repair permit
2024-11-19
Replacement of 200 amp (or less) electric panel - no plans required. installation shall comply with city of mesa codes and servicing electric utility requirements. do not disconnect utility wires or meters. schedule disconnect/reconnect with the serving utility and obtain utility service requirements specific to your permit. failure to schedule disconnect may result in additional util... see more
Valuation:
N/A
Permit #:
PMT24-09628
Status:
final
Fee:
$229
Permit Type:
Replacement of 20...
Building Type:
N/A
Residential utility repair permit
2024-05-13
Installation of roof-mounted utility interactive photovoltaic system 10 kw dc & 7.25 kw air conditioning photovoltaic solar array (new) utility air conditioning disconnect switch (new) srp 1-phase 3-wire (new) 125a | 120/240v enphase iq combiner x-iq-am1-240-4 photovoltaic air conditioning combiner panel
Valuation:
N/A
Permit #:
PMT24-09013
Status:
canceled
Fee:
$229
Permit Type:
Construction nois...
Building Type:
N/A
Electrical/mechanical permit
2024-07-03
New photovoltaic roof mounted system - 8.030 kw dc/6.000 kw air conditioning (n) gb41040 meter socket adapter w 40a/2p breaker (located on the inside bottom of adapter) (n) 60a fused visible lockable labeled utility dg disconnect switch eaton dg222nrb or equivalent with (2) 40a fuses 240v nema 3r ul listed (n) utility dg meter socket 100a milbank u5929-xl-ins or equivalent form 2s 120... see more
Valuation:
N/A
Permit #:
P24BP04619
Status:
final
Fee:
$81
Permit Type:
N/A
Building Type:
N/A
Construction and trades residential
2024-04-29
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code service upgrade per current electrical code. reviewer: gbald contact your electric service provider to verify any additional panel requirements description of work: (n) 175a derate (n) 175a derate
Valuation:
$750
Permit #:
CTR-102401229
Status:
final
Fee:
$300
Permit Type:
Service upgrade -...
Building Type:
Single family
Construction and trades residential
2024-06-11
Effective building codes: 2018 ibc 2018 irc 2018 imc 2018 ipc 2018 upc 2018 ifgc 2018 ispsc 2017 nec 2018 phx fire code service upgrade per current electrical code. reviewer: lkoll (no plans required) contact your electric service provider to verify any additional panel requirements description of work: upgrade ses to 200amp; 120/240volt; 1 phase; 3 wire service **********************... see more
Valuation:
$2,500
Permit #:
CTR-102404036
Status:
final
Fee:
$168
Permit Type:
Service upgrade -...
Building Type:
Single family
Construction and trades residential
2024-05-01
Effective building codes: 2018 irc 2017 nec. description of work: main panel upgrade 200a (225a bus 1ph) for photovoltaic install service upgrade per current electrical code contact your electric service provider to verify any additional panel requirements
Valuation:
$750
Permit #:
CTR-102403730
Status:
final
Fee:
$168
Permit Type:
Service upgrade -...
Building Type:
Single family
Residential solar permit
2024-04-10
Void - we are not able to accept the application address (443 w. 38th st. tucson az 85713). it is in the pima county jurisdiction. please contact pima county development services at 520-724-9000. new photovoltaic roof mounted system - 9.750 kw dc/7.600 kw air conditioning
Valuation:
N/A
Permit #:
TC-RES-0424-02125
Status:
canceled
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors See more

License # 333565
116
BZ Score
$17.9K
Avg Project
-
Projects
License # BL-2026-018
117
BZ Score
$26.6K
Avg Project
-
Projects
License # 334566
122
BZ Score
$2.8K
Avg Project
-
Projects