Location and Projects

Address
PO BOX 12386, La Crescenta, CA, 91224
Use our bidding system to request a quote

Rex Fire Protection, Inc

Rex Fire Protection, Inc, La, Po Box 12386, La Crescenta, CA (Employees: Robert Asatryan, Robert Asatryan, and Violet Hovsepian) holds a Fire Protection, Electrical license and 1 other license according to the California license board.

Their BuildZoom score of 100 ranks in the top 13% of 336,931 California licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Rex Fire Protection, Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Rex Fire Protection, Inc Contact Information

Phone: (818) 248-0332 Edit
Address: PO BOX 12386, La Crescenta, CA 91224 Edit

Building Permits by Rex Fire Protection, Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Fire sprinkler
2025-11-21
Relocate 4 sprinkler heads
Valuation:
N/A
Permit #:
25043-90000-01773
Status:
final
Fee:
N/A
Permit Type:
1 or 2 family dwe...
Building Type:
N/A
Miscellaneous permit for fire sprinklers to verify no changes are needed
Valuation:
N/A
Permit #:
25043-40000-02595
Status:
issued
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Sprinkler system multi family and commercial - new
2022-10-15
Install (1) sprinkler head over trash bin (155 degrees pendant head)
Valuation:
N/A
Permit #:
FPSS2205607
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire sprinkler
2024-01-05
Lowering heads
Valuation:
N/A
Permit #:
23043-90000-04867
Status:
final
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Fire extinguishing system
2017-11-16
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: relocate existing ansul system nozzles per plan total 6 gallon ansul system flow max 22 using 20 charbroilder 22 x 60 6 burner 24x36 (2) single burner 18 x18 (2) fryer 14 x15 convention oven box 268 item 36
Valuation:
N/A
Permit #:
FPSE1727454
Status:
issued
Fee:
N/A
Permit Type:
Kitchen hood
Building Type:
N/A
Fire extinguishing system
2017-11-16
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: relocate existing ansul system nozzles per plan ansul system 6 gallon flow max 22 using 18 flow. 24x36 (1) 6 burner range 14 x15 fryer (1) (3) 18x 28 broiler 22s 60charbroiler 22x48gridale (1) box 268 item 37
Valuation:
N/A
Permit #:
FPSE1727453
Status:
issued
Fee:
N/A
Permit Type:
Kitchen hood
Building Type:
N/A
Fire extinguishing system
2016-11-07
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: install (2) 460 system tank to cover appliances, hood, duct, plenum new system box 260 item 2 **revision to original permit fpse-1626543 total 25-flow available using 19 6-avaliable (2) 6-burner, griddle, charbroiler, fryer, oven, salvander
Valuation:
N/A
Permit #:
FPSE1626543
Status:
issued
Fee:
N/A
Permit Type:
Kitchen Hood
Building Type:
N/A
Fire extinguishing system
2019-05-09
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installing 2-3 gallonpyro chem system to cover hood, plenum duct and appliances. (2)pizza conveyer electric, 2 single burne, 1-6burner stove. box #282; item #32
Valuation:
N/A
Permit #:
FPSE1909290
Status:
issued
Fee:
N/A
Permit Type:
Kitchen Hood
Building Type:
N/A
Fire extinguishing system
2017-06-06
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: install 1.6 gallon pyro-chem system to cover hood, duct plenum and 13" single burner range box 265 item 17
Valuation:
N/A
Permit #:
FPSE1711314
Status:
issued
Fee:
N/A
Permit Type:
Kitchen Hood
Building Type:
N/A
Fire extinguishing system
2016-11-16
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: 6 gallon asul system on pre- piped hood. total 10 nozzlesto cover hood duct appliances. box 260 line36
Valuation:
N/A
Permit #:
FPSE1627168
Status:
issued
Fee:
N/A
Permit Type:
Kitchen hood
Building Type:
N/A
Fire extinguishing system
2015-03-05
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of 3 gallon protex system to cover hood/duct and appliances. 2 burner range 12 x24/charbroiler 18x24 total nozzles 6 max allow 10 fc using gel box 243 item 3
Valuation:
N/A
Permit #:
FPSE1503925
Status:
issued
Fee:
N/A
Permit Type:
Kitchen hood
Building Type:
N/A
Extinguishing system - new kitchen hood system
2015-06-13
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of pcc600 pyro chem fire sstem to cover hood appliance duct and plenum fryer 6 burner double deck broiler. total 20 flow points 17 ansul box 241 item 25
Valuation:
N/A
Permit #:
FPSE1429284
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire extinguishing system
2016-08-09
Install 3 gallon pyro clam system to cover hood duct plenum and appliances. charbroiled (18x48) fyer (14x15) 2 burners (10x24) pizza oven. total 10 flow allowed using 9 flow. box 257 item 38
Valuation:
N/A
Permit #:
FPSE1620239
Status:
issued
Fee:
N/A
Permit Type:
Kitchen hood
Building Type:
N/A
Extinguishing system - new kitchen hood system
2014-09-28
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of ansul system 4.5 gallon to cover hood duct & appliances. 4-burner range 24x24 griddle 24x60 2-fryers 14x15 total flow allowed 16 used 14. box #234 item#31
Valuation:
N/A
Permit #:
FPSE1407043
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Extinguishing system - alteration to kitchen hood system
2014-10-26
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: install 3 gallon ansul system to protect hood appliances duct & plenum charbroiler (18 x 34) 4 burner range (24x24) fryer (24x 24) total 6 nozzles 10 flow point box 235 item 18
Valuation:
N/A
Permit #:
FPSE1409402
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire extinguishing system
2015-02-09
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of 3-gallon protex system to protect hood duct and appliances. 18x46 charbroiler vertical broiler fryer
Valuation:
N/A
Permit #:
FPSE1502265
Status:
issued
Fee:
N/A
Permit Type:
Kitchen hood
Building Type:
N/A
Extinguishing system - new kitchen hood system
2013-10-26
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installtioin of 6 gallon anul system. protect hood duct plenum & appliances. (2) fryers 14x15 (3) 4 burner ranges 24x24 (1) charbroilers 22x22 griddle (1) 24x24 griddle (1)24x36 stock pot (1) 18x18 salamander (1) 14x72 total of 19 flow points used. box 221 item 46
Valuation:
N/A
Permit #:
FPSE1234798
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Extinguishing system - alteration to kitchen hood system
2013-08-19
Installation of hood or special extinguishing system in accordance with the glendale building and safety code:3-gallon and 6-gallon ansul system to cover hood duct and appliances 4-burner range (24x24) (2) vertical broiler 12x18 salamandar 14x24 gas charbroiler (2) 20x72 6-burner range (24x36). (box224 item32)
Valuation:
N/A
Permit #:
FPSE1303221
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Fire extinguishing system
2017-01-18
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of 45 gallon ansel system to cover hood appliances total 10 nozzles 261 #15
Valuation:
N/A
Permit #:
FPSE1700840
Status:
issued
Fee:
N/A
Permit Type:
Alterations
Building Type:
N/A
Extinguishing system - new kitchen hood system
2022-05-21
Install two three gallon pyro chem chem tanks to cover appliances hood and duct (2) 6 burner rnage (1) 72 charboiler 1 fryer 14x15
Valuation:
N/A
Permit #:
FPSE2119539
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A

Similar Contractors

License # 861406
122
BZ Score
-
Avg Project
-
Projects
License # 1106404
119
BZ Score
-
Avg Project
-
Projects