San Francisco Earthquake Retrofitting
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
San Francisco Earthquake Retrofitting Construction
San Francisco Earthquake Retrofitting, 221 Goodwin Dr, San Bruno, CA (Owned by: Aidan Gerard Leicester) holds a Painting And Decorating, General Building license according to the California license board.
Their BuildZoom score of 93 ranks in the top 27% of 336,931 California licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring San Francisco Earthquake Retrofitting, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Brace & bolt addition 5/8 anchor bolts with simpson set xp epoxy every 4 ft with 7 embedment to left rear and 20 ft of right wall addition 1/2 osb struct 1 to left rear and 10 ft of right side wall. 10d common at 6 e.n 12 field
Insulate front rear and right side perimter walls with woodrock insulation. addition 5/8 anchor bolts with simpson set xp epoxy every 4 ft with 7 embedment to left rear and 20 ft of right wall addition 1/2 osb struct 1 to left rear and 10 ft of right side wall. 10d common at 6 e.n 12 field
Brace & bolt existing foundation addition 5/8 anchor bolts (every 4 with epoxy 7 embedment use simpson uf plates where necessary. addition 1/2 struct 1 osb to rear crawl space. use either a35's or 1/4 sds screws to secure top plate to rim joist every 24 all work voltunary
# scanned # foundation work: install simpson universal connector plates every 4 feet to existing foundation. install a35 clips to rim joist and membrane every 2 feet. all retrofit work will be done in accordance with chapter a3 california brace and bolt program
Brace & bolt down walls to (e) foundation per prescriptive measures using simpson titen anchors 5/8-8 every 4ft install plywood bracing per required. this work performed in general conformance with ca existing building code appendix chpt a3 sfbc ab 108
Brace & bolt to (e) foundation for precriptive measures titen anchor 5/8-8 universal connectors plywood bracing every 4ft. this work performed in general conformance with ca existing building code appendix chpt a3 sfbc ab 108 5/8 x 10'@ 4 oc w tp 500 epoxy
Voluntary strengthening addition 5/8 anchor bolts every 4 ft with 7 embedment with epoxy.add 4d linear ft of osb struct 1 plywood addition 6 sos screw at top plate & rim joist where plywood is installed
Install 3 steel moment frames at 1st floor garage for soft storey seismic retrofit in accordance with sf mandatory soft storey program per sfbc chapter 34b; 2012 iebc appendix a-4
Brace and bolt perimeter walls per prescriptive measures. 5/8 threaded rod at 4 with 7 embedment. 1/2 osb struct 1 plywood bracing use expoxy to anchor
This permit is for work to be performed in general conformance with california existing building code appendix chapter a3 (s.f.b.c. ab-108) 5/8 x 10 @ 4'0 o.c. with tp-500 epoxy
Soft story seismic stregthening. new shearwall and anchors at perimeter and transverse walls. 2 new momentframes. 4 new grade beams. 2012 iebc appendix a-4
This permit is for work to be performed in general conformance with california existing building code appendix chapter a3 (s.f.b.c. ab-108)5/8"x10 @4'0 o.c. with tp-500 epoxy
Volatary strengtheing addition 40 simpson ulfp sds3 to existing mudslide crawl space every 3'0 addition 1/2 struct 1 cdx. plywood to existing criddle walls in basement addition 3by 4 studs where needed for nailing. use 6-12 patch
Addition 5/8 anchor bolts at 4 fl with expoxy 7 at east side of house addition plywood struct 1 osp to south east wall of house. voluntary strenghthening