×

We'll help you find the right contractor.

Share your project details and we'll reach out to Taylor Brothers Fire and Safety Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
Is this your business? Claim now >
T

Location and Projects

Address
3604 S BANNER ST STE. 104, Boise, ID, 83709
Use our bidding system to request a quote

Taylor Brothers Fire and Safety Construction

Based in Boise, Taylor Brothers Fire and Safety Inc has provided fire protection services in Idaho for over 14 years. The company specializes in designing, installing, and servicing fire suppression systems for a range of property types, including commercial buildings and industrial facilities. Taylor Brothers Fire and Safety Inc offers expertise in fire alarm systems, sprinkler systems, fire extinguishers, and related safety solutions. Their service area includes Boise and the greater Treasure Valley, extending technical support to clients seeking reliable fire prevention strategies. The firm is equipped to handle both new system installations and routine maintenance, ensuring compliance with safety codes and regulations. Through a focus on fire safety for businesses and property managers, Taylor Brothers Fire and Safety Inc delivers system design, inspection, and emergency repair services tailored to the needs of each project.

Taylor Brothers Fire and Safety Inc Services

Start a project today:

Taylor Brothers Fire and Safety Inc Contact Information

Phone: (208) 344-8711 Edit
Address: 3604 S BANNER ST STE. 104, Boise, ID 83709 Edit

Building Permits by Taylor Brothers Fire and Safety Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
603-604-fire sprinklers
2021-01-27
System has been utilizing incorrect nozzle positions above the two vat fryer. this permit is to allow the correction of the nozzle placement to directly above the fryers
Valuation:
N/A
Permit #:
FIR20-00808
Status:
final
Fee:
$224
Permit Type:
Alteration
Building Type:
Commercial
605-cooking hood system
2021-09-20
Modification of an existing pyro chem system moving the control head and cylinder closer to the protected hood
Valuation:
N/A
Permit #:
FIR21-00295
Status:
final
Fee:
$175
Permit Type:
N/A
Building Type:
Commercial
605-cooking hood system
2021-10-27
Modification of an exisiting ansul r-102 to accomodate the appliances for the new restaurant
Valuation:
N/A
Permit #:
FIR21-00515
Status:
final
Fee:
$476
Permit Type:
N/A
Building Type:
Commercial
605-cooking hood system
2021-02-16
Modification of the ansul r-102 new customer with a new appliance line up will modify pipe and detection lines to accommodate
Valuation:
N/A
Permit #:
FIR20-00553
Status:
triage
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial
605-cooking hood system
2021-09-20
Modification of an existing pyro chem system to accommodate a new appliance line
Valuation:
N/A
Permit #:
FIR21-00294
Status:
final
Fee:
$219
Permit Type:
N/A
Building Type:
Commercial
605-cooking hood system
2021-08-03
Removal of the old obsolete ansul system addition of a new ansul r-102
Valuation:
N/A
Permit #:
FIR21-00251
Status:
final
Fee:
$214
Permit Type:
N/A
Building Type:
Commercial
Grand lodge is adding one new fryer one new 3n nozzle will be added above it. system is within the flow count requirements set by ansul
Valuation:
N/A
Permit #:
C-FHOOD-2020-0040
Status:
final
Fee:
$125
Permit Type:
N/A
Building Type:
N/A
Installation of a pyro chem monarch in the ope face spray booth prep deck
Valuation:
N/A
Permit #:
C-FHOOD-2020-0005
Status:
final
Fee:
$125
Permit Type:
N/A
Building Type:
N/A
Installation of dry chemical system in pain mix room
Valuation:
N/A
Permit #:
C-FHOOD-2020-0004
Status:
final
Fee:
$125
Permit Type:
N/A
Building Type:
N/A
Fire alarm permit
2015-10-28
Fire alarm/commercial/best bath systems/provide full area heat detection. future monitoring for fire sprinkler riser, use clients sound system for notification, turn off effect lights and turn on house lights on alarm
Valuation:
$0
Permit #:
FP15-00050
Status:
Approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
601-602-fire alarms
2014-07-05
This permit scope of work is to extend the existing manual system in to the new tenant space. this includes new ceiling mount notification placed on an existing spare nac on the existing remote power supply. associated with building permit bld13-03203
Valuation:
N/A
Permit #:
FIR14-00001
Status:
final
Fee:
$154
Permit Type:
Tenant improvemen...
Building Type:
Commercial
601-602-fire alarms
2016-02-17
This scope of work is to provide a conventional fire alarm panel for sprinkler system monitoring. scope includes providing a smoke above the facp a pull station and zones for monitoring the sprinkler system. associated with building permit bld15-01357. plan modification 9-1-15 for dry sprinkler system monitoring
Valuation:
N/A
Permit #:
FIR15-00354
Status:
final
Fee:
$304
Permit Type:
Tenant improvemen...
Building Type:
Commercial
601-602-fire alarms
2016-02-06
This scope of work is to replace an existing conventional fire alarm system with a new addressable fire alarm system. work to include a pull station a smoke detector above the facp sprinkler riser monitoring and hvac shutdown. not associated with a building permit
Valuation:
N/A
Permit #:
FIR15-00530
Status:
final
Fee:
$313
Permit Type:
Replacement
Building Type:
Commercial
601-602-fire alarms
2016-05-21
Replacement of old halon suppression system and installation of a new fm-200 clean agent suppression system. system will be installed per nfpa 2001 and manufacturers specifications. drawings and control calculations has been performed by fundamental alarm designs llc and the suppression system components have been designed by taylor brothers fire & safety per manufacturers specificati... see more
Valuation:
N/A
Permit #:
FIR15-00824
Status:
final
Fee:
$150
Permit Type:
New
Building Type:
Commercial
601-602-fire alarms
2016-06-12
This quick permit is to addition one notification device on the first floor to accommodate coverage issues due to a door that had been added previously. the new device shall be added to the first floor remote power supply circuit #1. this project is not associated with a building permit
Valuation:
N/A
Permit #:
FIR15-00874
Status:
final
Fee:
$154
Permit Type:
Alteration
Building Type:
Commercial
603-604-fire sprinklers
2016-12-30
[idaho state insurance fund] the fire protection scope of work consists of clean agent system for the server room. a new sapphire clean agent suppression system utilizing novec 1230 fluid will be installed per nfpa 2001 and manufacturers specifications. there does not seem to be an associated building permit at this time note: the clean agent system does not remove the requirement for... see more
Valuation:
N/A
Permit #:
FIR16-00086
Status:
final
Fee:
$150
Permit Type:
Alteration
Building Type:
Commercial
601-602-fire alarms
2017-01-30
This scope of work is to addition a new smoke detector with a relay to an existing system for flashing elevator hat light actuation. the new detector and relay will be located on the first floor mechanical room. this project is not associated with a building permit
Valuation:
N/A
Permit #:
FIR16-00501
Status:
final
Fee:
$154
Permit Type:
Alteration
Building Type:
Commercial
601-602-fire alarms
2017-04-02
This project is to provide a zone expander card (remote mounted in an sk-2190 accessory panel) via sbus to an existing silent knight 5208 facp to monitor alarm trouble and supervisory status of a co2 releasing panel. the installation of the releasing panel is under the co2 permit (fir16-00521) and not part of this scope of work
Valuation:
N/A
Permit #:
FIR16-00611
Status:
final
Fee:
$154
Permit Type:
Alteration
Building Type:
Commercial
601-602-fire alarms
2017-04-16
This scope of work is to extend the existing manual system in to the new expansion area warehouse and monitor a new sprinkler riser system being installed as well as fire pump monitoring functions. visual notification shall be provided in the restrooms while audible notification will be supplied in the warehouse areas. attached documentation supports the areas have been designed with ... see more
Valuation:
N/A
Permit #:
FIR16-00656
Status:
final
Fee:
$150
Permit Type:
New
Building Type:
Commercial
601-602-fire alarms
2016-12-05
This permit scope of work is to replace the existing dact with a cellular communicator for offsite monitoring of a fire alarm system being installed by others under fir16-00132 in a shell/core building. associated with building permit bld15-03583
Valuation:
N/A
Permit #:
FIR16-00375
Status:
final
Fee:
$154
Permit Type:
Replacement
Building Type:
Commercial

Similar Contractors See more

License # RCE-1954
121
BZ Score
$210K
Avg Project
-
Projects
License # RCE-57624
127
BZ Score
$193K
Avg Project
-
Projects
License # RCE-69636
121
BZ Score
$6.5K
Avg Project
-
Projects

Taylor Brothers Fire and Safety Inc Reviews

BuildZoom hasn't received any reviews for Taylor Brothers Fire and Safety Inc. Click here to be alerted when reviews are posted about them.
Please write a review about Taylor Brothers Fire and Safety Inc
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.