Turner Tree Management LLC at 1634 N 19th Ave, Phoenix, AZ 85009, held a license (#244016) with the Arizona contractors license board. We last verified the license was expired on 09-23-2021.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 71,576 Arizona contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
Hospital - single story medical emergency facility w/med gas fire sprinklers/alarms fire access/signage landscaping/irrigation site lighting trash/decon enclosure
765 sq ft remodel of existing 29.987 sq ft hangar to expand 1st floor waiting area for intel.( a3/b/s2/f1 iib ) at phoenix mesa gateway. to include: demolish 1 hr partitions framing foundation doors window susp. clg conc. pad & finishes. modify mechanical, plumbing elect. power lighting and fire sprinklers and fire alarm
Providing new clsc/r loop for ch3 cvc lab from existing chws/r main. providing new chw filter station enclosing pumps and filters and controls equipment as necessary. utilities affected inlude chws/r clcs/r ofa indirect drain electrical power controls
C4 - cam04 installationinstall the cam04 link and associated globals. facilities affected include ofa gn2 photovoltaic pcws/r gex power and telecom. fees deferred to q1/2008 chandler payment per arrangement between city and intel
C4 aph01 - appv & cpv upgrades to hybridrelocate and upgrade aph01 and cpv01 tools. facilities affected include ofa pcws/r power and telecom. fees deferred to q3/2008 chandler payment per arrangement between city and intel
Reconfigure the existing cam08 link cam08 globals and cam06 globals. facilities affected include: ofa photovoltaic gn2 pcws/r gex power and telecom. fees deferred to q1/2009 per arrangement between city and intel
Reconfigure the existing cam206 link and cam206 globals. facilities affected include ofa photovoltaic gn2 pcws/r gex power and telecom.fees deferred to q2/2009 chandler payment per arrangement between city and intel
Demolish horizontal chase and utilities. demolish tps01 tool. relocate symtek and 200m saw tools. reconnect mechanical and electrical services for multiple tools in atrl area previously fed from horizontal chase. facilities affected include ofa photovoltaic gn2 di pcw gex power and telecom. fees deferred to q4/2008 chandler payment per arrangement between city and intel
Remove/replace existing pass-thru doors in c4 building 1st floor at 4 locations. expand pass-thru and install new doors. provide electrial/security as necessary. utilities affected inlude: architectural electrical/security.fees deferred to q3/2008 chandler payment per arrangement between city and intel
Intel - repair fire protection pipes at dobson rd - excavate to existing piv. remove piv and 18 of fireline. install new fireline and piv. replace riser and backfill and compact must notify fire dept. if fire sprinkler line will be temporarily out of service
Relocate dhg/vqe video lab from 4th floor to 1st floor and relocate ehs ergo lab from 1st floor to 4th floor. (the 2 labs will swap locations) utilities affected include: hvac fire protection electrical power telecom & lighting. fees deferred to q1/2009 chandler payment per arrangement between city and intel
Replace 1 existing lce tool with a new generation tool in the c3 cvc circuit edit lab. utilities affected include ofa n2 heat exhaust chilled water electrical power and tgms.fees deferred to q3/2009 chandler payment per arrangement between city and intel
Relocate shbi tool from c4 burn-in area to c3 burn-in lab. utilities/disciplines affected: ofa tvac pcws/r exhaust electrical power. fees deferred to q4/2008 chandler payment per arrangement between city and intel
Convert existing conference and storage area into 2 b type conference rooms. revise ductwork and addition an air terminal unit for improved air distribution and sound quality. revise fire protection sprinklers. utilities affected include: hvac fire protection electrical power lighting and telecom. fees deferred to q3/2010 chandler payment per agreement between city and intel
Upgrade the existing sihsm03 link to use a single utility chase along with some misc. tool upgrades. facilities affected include ofa photovoltaic gex power and telecom. fees deferred to q1/2009 chandler payment per arrangement between city and intel
Relocate 3 thermal station tools and install 2 additional thermal station tools in the c4 sttd lab. provide utilities for 5 thermal stations and 1 utility sink. utilities affected include: ofa pcws/r ro water aw drain electrical power. fees deferred to q3/2008 chandler payment per arrangment between city and intel
Reconfigure the existing exp05 link and addition 4 new tools. facilities affected include ofa gn2 gex bottled gases (ar and o2) power and telecom. fees deferred to q3/2008 chandler payment per arrangement between city and intel
C4 dag80 grinder and ngs80 saw lspdemo existing sw03 tool and install dag80 and ngs80 tools. facilities affected include ofa dis/r awn gex and power. fees deferred to q2/2009 chandler payment per agreement between city and intel
Upgrade the facilites for tst712 & tst721 to include the installation of a high speed tester and v8 handler. facilites affected include ofa photovoltaic pcws/r power and telecom. fees deferred to q3/2009 chandler payment per agreement between city and intel
Relocate veeco tool demolish existing utility chase and install mik01 tol with associated workstation. facilities affected include ofa photovoltaic dis/r awn power and telecom. fees deferred to q3/2008 chandler payment per arrangement between city and intel
According to the Arizona Registrar of Contractors, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.