Share your project details and we'll reach out to
Twins Roofing Incorporated
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Twins Roofing Incorporated at 13328 GLENOAKS BL, Sylmar, CA 91342, held a Roofer license (#670381) with the California contractors license board with an expiration date of 06-30-2029. We last verified the license was inactive on 01-20-2026.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 336,931 California contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our project planner to be easily matched to qualified, licensed professionals in your area.
Location: irvine blvd. and magazine road - tying into existing 5 sce conduit and at&t vault within irvine blvd. at the intersection of magazine road. the trenching linear footage shown below is only for the work being done within the irvine blvd. street right-of-way
Re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement >50% of the total roof area apply cool roof product labeled and certified by cool roof rating council (crrc). cool roof may be required for non-residental buildings per title 24 part 6 section 149(b)
Re-roof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roofing council (ccrc). cool roof may be required for non-residential buildings per title 24 part 6 section 149(b)
Re-roof with class a or b material weighing less than 6 pound per sq. ft. reroof with class a or b material weighing less than 6 pounds per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roofing council (ccrc). cool roof may be required for nonresidential buildings per title 24 part 6 section 149(b)
Re-roof with class a or b material weighing less than 6 pound per sq. ft. for residential roof replacement > 50% of the total roof area apply cool roof product labeled and certified by cool roofing council (ccrc)
Residential reroof as follows:- class a garage - - this is a change of roofing material (y/n):n - proposed roofing material: built up roof - squares (100 sf) being installed: 3 squares - tear off existing (y/n):y - existing layers of roofing:2 - new sheathing being installed (y/n):n - high fire hazard zone (y/n):n - - note: all tear-offs require solid sheathing. install min. 3/8 struc... see more
Residential reroof as follows:- class a house - - this is a change of roofing material (y/n):n - proposed roofing material: built up roof - squares (100 sf) being installed: 14 squares - tear off existing (y/n):y - existing layers of roofing:2 - new sheathing being installed (y/n):n - high fire hazard zone (y/n):n - - note: all tear-offs require solid sheathing. install min. 3/8 struc... see more
Material: built up roof torch app. class a - no. of squares: 28 - tear off existing (y/n): y - existing no. of layers: 1 - new sheathing (y/n): n - note: all tear-offs require solid sheathing. install min. 3/8 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Material:25 yr shingle class a - no. of squares:22 - tear of existing (y/n):y - existing no. of layers: - new sheathing (y/n):y - note: all tear-offs require solid sheathing. install min. 1/2 structural wood panel with 6d common nails at 6:12. this may be installed over existing spaced sheathing. -
Tear off (e) roof and install 140 squares. of class a b.u.r. system over (e) sheathing. valuation to be verified by the field inspector. a cool roof labeled and certified by crrc is required for re-roofing of all non-residential buildings with roofs sloping 16.7% or less per section 149(b) of title 24
Tear off (e) roof and install 1/2 cdx plywood and 36 squares. of class a comparable. shingles. tear off (e) flat roof and install 4 squares. of class a b.u.r. system over (e) sheathing. smoke detectors required. valuation to be verified by the field inspector
Tear off (e) roof install 2-ply sheet with hot asphalt and 1-ply cap sheet with hot asphalt built up roof system class a 85sqs. a cool roof labeled and certified by crrc is required for re-roofing of all non-residential buildings with roofs sloping 16.7% or less per section 149
Tear off (e) roof and install 42 squares. of class a b.u.r. system over (e) sheathing. a cool roof labeled and certified by crrc is required for re-roofing of all non-residential buildings with roofs sloping 16.7% or less per section 149(b) of title 24
Supplemental permit for change of work description on original permit to include garage. new work description - tear off (e) roof and apply 1/2 cdx plywood and 33 squares of class a comparable. shingles. duplex and garage. smoke detectors required. valuation to be verified by the field inspector
Tear off (e) roof apply 1/2 cdx plywood on detached garage only. install 30 year composition shingles class a on sloped roof install torch down capsheet class a on flat roof house and detached garage. 27sqs. smoke detectors required
Tear off (e) roof. re-roof with 4x8 1/2 osb plywood apply 2x2 edge metal 15lb felt & 25yr composition shingles class a material aprox. 17sq house & att.garage. smoke detectors are required
According to the California Contractors State License Board, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
Check this license's status for Twins Roofing Incorporated at the California Contractors State License Board.
This is a sample of licensing data; click here to access a complete history.