United Fire Services Inc, Canoga Park, Po Box 9007, Canoga Park, CA (Employees: Aviva Shetrit, Aviva Shetrit, and Eli Shetrit) holds a Fire Protection license according to the California license board.
Their BuildZoom score of 94 ranks in the top 24% of 336,931 California licensed contractors.
Their license was verified as active when we last checked. If you are thinking of hiring United Fire Services Inc, we recommend double-checking their license status with the license board and using our bidding system to get competitive quotes.
Epc - installation of a hood fire suppression system revision com-2304208 - epc - customer changed the cooking equipment under the hood resubmitted plans show the changes in the nozzle coverage
Installation of 2 x pcl-300s to cover 10 hood with 1 duct 48 gas charbroiler and 60 gas charbroiler 6'-2 hood with 1 duct 16 fryer vertical broiler and 24 griddle 5'-5 hood with 1 duct and 2 rice cookers
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: install at pyrochem-pcl-460 to cover 12'0 hood with 1 duct 6 burner range 36 x 24 gas radiant charbroiler and 3 shawarma broilers 18 x 18 each remaining flow points is 3 flow points
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of pyro chem pcl-160 to cover 6'0 hood with 1 duct 2 burner range 24 charbroiler and 24 griddle no remain flow points
Epc - installation of a new fire suppression system for commercial kitchen hood. hood installation by others com-2308582 see revision com-2317473: nozzles and upgrade to the tank as a result of changes to the appliances
Scope change 10/4/2018. la jolla. building mechanical electrical plumbing permits for a tenant improvement in an existing commercial building. changing use from a education tutorial center to a pizza takeout. work to include new walls new walk-in cooler new type 1 hood new sinks. ljpd-3 geo haz 52 n-app-2 transit priority area
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of fire suppression system for 2 hoods in kitchen area. hood 1 with 2 stuck puts 4 flow points used 11 remaining. hood 2 with 48 diameter griddle 7 flow points used from task 4 remaining. box #279; item #6
Scope change 10/4/2018. la jolla. building mechanical electrical plumbing permits for a tenant improvement in an existing commercial building. changing use from a education tutorial center to a pizza takeout. work to include new walls new walk-in cooler new type 1 hood new sinks. ljpd-3 geo haz 52 n-app-2 transit priority area
Installation of hood or special extinguishing system in accordance with the glendale building and safety code:installation of pyro chem pcl 160 tank to existing pyro chem pcl 460 to cover two fryers. 0 remaining flow points from pcl 460tank 1 remaining flow point from pcl 160 tank box 284 item 5
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: installation of fire suppression system (3) gallon pyro chem system with 10 flow points (5) flow points going to hood #1 and 2 flow points going to hood #2. 3-flow points remaining from 3 gallon system box 280 item 9
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: install pyro chem pcl-160 system to cover 4'0 hood with 1 dict and 6 burner range. there are no flow points remain 5 available flow points 5 flow points used box 276 item 23
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: install pyro chem pcl-300 to cover 10'hood with 1 duct fryer 16"x18 6 burner range 36"x24 and charbroiler 48"x24. 10 flow points used 0 available. box #275; item #45
Installation of hood or special extinguishing system in accordance with the glendale building and safety code: adjust nozzles existing pyro chem 2xpcl-600s to cover (hoood#1) 12'-0 hood with 1 duct 20 wok 2 fryers over, (hood #2)4'-0 w/1 duct & pizza oven (hood #3)12'-0 hood w/1duct 12 burner range 36 slam-ander &24 gas rad. charbroiler (hood#4) 12'-0 hood with 1 duct 2-36 salamanders... see more