We'll help you find the right contractor.

Share your project details and we'll reach out to Western Allied Construction, Inc so you don't have to.

We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.

Get Started
W

Location and Projects

Address
8141 2nd St, Downey, CA, 90241
Use our bidding system to request a quote

Western Allied Construction HVAC/Mechanical Contractor

Western Allied Construction, Inc, 8141 2nd St, Downey, CA (Employees: Donald Edward Ellwanger Jr, Harold Waterman, and James Arthur Muscarella) holds a Plumbing, Warm Air Heating, Ventilating And Air Conditioning license and 5 other licenses according to the California license board.

Their BuildZoom score of 114 ranks in the top 2% of 336,931 California licensed contractors.

Their license was verified as active when we last checked. If you are thinking of hiring Western Allied Construction, Inc, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.

Western Allied Construction, Inc Services

Start a project today:

Western Allied Construction, Inc Contact Information

Phone: (650) 326-8290
Address: 8141 2nd St, Downey, CA 90241

Western Allied Construction, Inc Downey

Quality

114
98th percentile
Pro tip: We generally recommend hiring a contractor with a score higher than 95.
Western Allied Construction, Inc has a BuildZoom score of 114, which places them above 98% of 336,931 contractors in California.

Activity

58 projects
2025
44 projects
2024
28 projects
2023
Our building permit records indicate that Western Allied Construction, Inc has worked on at least 130.0 projects over the past 3 years.

This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.

Experience

27 projects
Commercial Renovations
9 projects
Home Additions
3 projects
New Constructions
78 projects
HVAC projects
32 projects
Mechanical projects
Analyzing permits over the last 4 years shows that Western Allied Construction, Inc mostly works on hvac project and mechanical project projects.

Pricing

2 projects
< $5k
6 projects
$5k-$20k
3 projects
$20k-$50k
18 projects
$50k-$100k
10 projects
$100k-$250k
8 projects
$250k-$500k
3 projects
$500k-$1mil
Value Not Public: 76.0 projects
The typical size of their permits is approximately $98,900. This graph shows the distribution of these job values.
Pro tip: For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.

Western Allied Construction, Inc Reviews
5 out of 5 stars, based on 1 review

  • By Anita G.
    March 24, 2017
    Verified Hire

    They did very good work and in a timely manner.

Please write a review about Western Allied Construction, Inc
1 Rate this contractor
Click stars to rate
2 Provide a detailed review of this contractor.


Building Permits by Western Allied Construction, Inc

Sort by: Notable Notable | Date Date | Job Value Job Value
Building permit revision
2025-04-14
No update to project scope. project update is to capture rfis with clarification details for city record. original scope of project is to replace (11) existing air conditioning units on the roof of the multipurpose building. this includes safe-off removing (11) existing air conditioning units upgrading the structural supports replacing (11) new air conditioning units and tying them in... see more
Valuation:
N/A
Permit #:
BLD2025-00440-001
Status:
triage
Fee:
$172
Permit Type:
N/A
Building Type:
N/A
Replacement of (e) ventilation (outside air) fan with new outside air fan. scope includes title 24 required interlocks and control for occupied use. provide new dedicated circuit to new ventilation fan (373w) and to new
Valuation:
$50,000
Permit #:
BS2400340
Status:
issued
Fee:
N/A
Permit Type:
Repair & maintenance
Building Type:
Office
Commercial/industrial
2024-10-29
Scope of work: like for like replacement of (2) rooftop hvac units and (1) split system. -demo existing two rooftop units and condensing unit for split system on roof. -demo existing ducted indoor ahu for split system on level 1 atm room. -install new rooftop units and condensing unit for split system on roof. -install new ducted indoor ahu for split system on level 1 atm room. -repla... see more
Valuation:
$95,000
Permit #:
2024 110663 CI
Status:
issued
Fee:
$1,831
Permit Type:
Bank
Building Type:
N/A
Building permit
2024-09-27
The scope of the project will be to replace (11) existing air conditioning units on the roof of the multipurpose building. this includes safe-off removing (11) existing air conditioning units upgrading the structural supports the new air conditioning units replacing (11) new air conditioning units and tying them into the system. gas piping will be rerouted on the roof. reuse duct smok... see more
Valuation:
$200,000
Permit #:
BLD2025-00440
Status:
issued
Fee:
$5,832
Permit Type:
Heating and/or ai...
Building Type:
N/A
(e-plan) renovations to an (e) commercial building major seismic strengthening improvements to the (e) main entrance exterior (n) entry canopy facade renovation (n) lobby interior alterations (n) tenant improvement common area upgrades (n) 6th floor roofing
Valuation:
$6,250,000
Permit #:
BS2005280
Status:
final
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial low gen
Tenant improvement - mechanical - finishes and hvac redistribution
Valuation:
$240,000
Permit #:
BS2408026
Status:
issued
Fee:
N/A
Permit Type:
Tenant improvement
Building Type:
Office
Building pre-application
2024-08-28
The least intrusive and most cost-effective way according to wa is to install 2 ductless split high wall fan coil units above the lockers. 2 condensers will be located outside on a wall mounted rack with stabilizing legs. the units will most probably be samsung. as determined western allied will install the inside and outside units. rymax will handle the electrical needs. facilities w... see more
Valuation:
$75,000
Permit #:
BPA24-2371
Status:
triage
Fee:
N/A
Permit Type:
Commercial
Building Type:
N/A
Building permit
2024-04-25
Replace existing rooftop component of hvac equipment and riser piping for a commercial building
Valuation:
$450,000
Permit #:
BLD2024-01137
Status:
final
Fee:
$3,066
Permit Type:
Repair
Building Type:
N/A
Commercial/industrial
2025-07-21
1) remove an existing rooftop unit 2) replace with a new like for like 50-ton unit at same location
Valuation:
$215,000
Permit #:
2025 120140 CI
Status:
issued
Fee:
$1,950
Permit Type:
Office
Building Type:
N/A
Commercial - combo
2025-09-02
T/i- replace (2) rooftop air conditioning (cooling-only) dx units like for like - 50-ton and 60-ton (elec mech)
Valuation:
$479,452
Permit #:
CB24-0329
Status:
final
Fee:
$17,041
Permit Type:
N/A
Building Type:
N/A
Building permit
2025-09-22
Addition of (1) chiller (1) ahu and (2) pumps with vfds
Valuation:
$741,869
Permit #:
BLD2025-02634
Status:
filed
Fee:
$1,967
Permit Type:
Alteration
Building Type:
N/A
Mechanical tenant improvement (non-structural) to addition private offices. no change of use. approx 2500 sqft
Valuation:
$93,750
Permit #:
BS2500864
Status:
issued
Fee:
N/A
Permit Type:
Tenant improvement
Building Type:
Office
Unit 300 - interior tenant improvement; office use. ductwork and diffusers
Valuation:
$155,000
Permit #:
BS2406293
Status:
issued
Fee:
N/A
Permit Type:
N/A
Building Type:
Commercial low gen
Remove and replace rooftop air conditioning units w/like for like capacity and in same location on the roof
Valuation:
$98,000
Permit #:
202501098011
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
31 - lending inst...
Building permit
2025-01-15
A tenant improvement to demolish interior to return to original shell. occupancy b. approx 11 755sf
Valuation:
$100,000
Permit #:
BLD2025-00127
Status:
final
Fee:
$1,105
Permit Type:
Demolition
Building Type:
N/A
Work category: 5p; - lab sinks and faucets - icemaker w drain - electric water heater with expansion tank mixing valve and circulation pump for tempered water loop - emergency eyewash showers - point-of-use sump pumps - extension of existing vac system to new csps and equipment - extension of existing co2 system to new incubators. - extending new tempered water loop to existing emerge... see more
Valuation:
N/A
Permit #:
PW20241016432
Status:
complete
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Building - pre application
2024-08-16
Replace (2) rooftop air conditioning (cooling-only) dx units like for like - 50-ton and 60-ton
Valuation:
$479,452
Permit #:
PREBLD24-0590
Status:
approved
Fee:
$94
Permit Type:
N/A
Building Type:
N/A
Mechanical tenant improvement - replace (e) co system wit22 new carbon monoxide sensors and 61 (e) co2 sensors & associated controls in parking garage
Valuation:
$93,000
Permit #:
BS2502067
Status:
issued
Fee:
N/A
Permit Type:
Repair & maintenance
Building Type:
Parking garage
Commercial hvac changeout
2025-02-06
Demolish rooftop package units (rtu-1 and rtu-2) and install with like-for-like units on existing adapter curbs. demolish outdoor condensing unit (cu-1) and and indoor fan coil unit (fcu-1) of ductless mini-split heat pump and install like-for-like units
Valuation:
$99,000
Permit #:
MECC-2023-0031
Status:
complete
Fee:
$315
Permit Type:
N/A
Building Type:
N/A
Commercial trade
2023-06-29
Remove and replace existing (4) commercial rooftop air conditioning units and replace with (4) new commercial air conditioning rooftop units. mount new rtu1 rtu2 rtu3 and rtu4 on existing adaptor curbs
Valuation:
$98,900
Permit #:
B23-1017
Status:
final
Fee:
$828
Permit Type:
N/A
Building Type:
N/A