Share your project details and we'll reach out to
Western Systems Inc
so you don't have to.
We'll also connect you with other vetted professionals who are a strong match for your project. That way, you can compare quotes, meet different contractors, and make the choice that feels right for you.
Western Systems Inc at 1203 TWIN PEAKS CL, Longmont, CO 80503, held a Roofer license (#) with the Denver contractors license board with an expiration date of 12-31-2014. We last verified the license was expired on 08-26-2024.
Their BuildZoom score is 0 because we haven’t been able to verify an active license. As a result, they’re not ranked in the top 50% of 55,949 Colorado contractors.
If you’re thinking about hiring them, we recommend double-checking their license status with your local licensing authority. Alternatively, use our bidding system to be easily matched to qualified, licensed professionals in your area.
Tenant finish and facade change for goodyear service center formerly foothills theatre minor amendment 69-00 for change of use and facade remodel requires backflow preventers on domestic & fire lines
New single family residence with 1359 sq. ft. basement. building height is 39.5 based on average of the height of all 4 sides. basement finish added 11/28/00 - bedroom bathroom gameroom
Reroof over existing asphalt roof with 1 1/2 foam insulation (min r-11) & duro-last membrane per mfg specs for high wind installation. utilize existing slope to drain. roof contains internal & overflow drains. provide manufactured installation requirements at time of inspection
Reroof existing church/school building - remove rock ballast install 1/4 densdeck gyp fire board & duro-last membrane roof mechanically fastened to decking - usr-1492 - new hope christian fellowship ref: bcn-050025 & bcn-050094 04/26/06 - letter to remind of 05/28/06 expiration date (pjg)
Reroof over existing asphalt roof with insulation & duro-last membrane to ul class a fire rating & fm high wind rating. 12 separate buildings - storage units (roofer did not tell us that there were separate buildings)
Remove rock ballast from roof. reroof with insulation board & duro-last single ply membrane to u.l. class a fire rating per manufacturers installation recommendations and high wind rating. roof has positive slope verify slope at drains
Remove river rock reroof over epdm with insulation and bondcote membrane to mfg specs (provide specs @ installation inspection) new roof to be class a firerated and installed to high wind specs. roof is sloped to gutter at rear underlying metal deck & insulation approx 82.5 squares
Fill flutes of existing metal roof with eps & 1 iso. install rond cote to manf. installation requirments (provide for review during inspection) for high wind rating. provide adequate drainage to existing roof gutters (2/12 min)
Overlay existing b.u.r. with 3/8 recovery board install bond cote single ply roofing to mfg specifications maintaining a class a roof roof slopes to drains. provide 1/4 per ft drainage roof drains & overflows
Reroof over existing metal roof with eps strips to fill flutes 1 1/2 iso insulation board and mechanically attached durolast single ply membrane class a roof slopes 1/12 to gutters. installed as per mfg specs
Remove rock ballast. install insulation & duro-last membrane over existing epdm to mfg specs ul class a and high wind rating. deck sloped to drain. roof to be inspected and warranted by duro-last
Remove rock from roof. reroof over existing rubber roof with insulation & mechanically attached duro-last membrane to u.l. class a fire & high wind rating. verify postive roof drainage
Cover existing metal roof with eps to fill flutes 1 iso over top and install class a bondcote single ply membrane per mfg specifications for high wind areas 2/12 pitch minimum slopes to gutters on both sides
Tear off existing epdm & wood fiber board install 3/8 insulation boards & mechanically attach stevens single ply membrane per mfg specs. also addition taper where needed for drainage 1/4 slope class a
Tear off existing roof to concrete deck. install r-19 insulation & duro-last membrane roofing system conforming to ul class a fire rating and fm high wind rating
Provide duro last roof on recovery board over existing tar & gravel roof. install per duro last specifications and provide during inspection. provide adequate slope to drains. approx 13 squares
Reroof with 2 r-14 insulation & duro-last membrance to mfg specifications over ixisting single layer of modified bitumen existing roof slopes to gutter on 2 sides. verify adequate drainage
Reroof with insulation & duro-last mechanically fastened membrane over existing roof to u.l. class a fire rating & high wind ratings per manufacturers recomendations. verify adequate roof drainage
Reroof 2 existing commercial lab buildings - duro last single p/4 membrane over existing commerical metal roof - warren analytical labs/swift & co - usr-864/spr-160
According to the City and County of Denver Community Planning and Development, the status of this license was at one point cancelled. However, this information may have changed. If this is your business, please update your license status.
This is a sample of licensing data; click here to access a complete history.