Updated: Dec 23, 2025
Location and Projects
Address
215 Tower Dr, Middletown, NY, 10941
Use our bidding system to
request a quote
Etak Systems Construction
Their BuildZoom score of 0 does not rank in the top 50% of New York contractors.
If you are thinking of hiring Etak Systems LLC, we recommend double-checking their license status with the license board and using our project planner to get competitive quotes.
Etak Systems LLC Services
Start a project today:
Etak Systems LLC Contact Information
Phone Number: (704) 398-9941
Edit
Address: 215 Tower Dr, Middletown, NY 10941
Edit
Do you work for this business? Unlock this free profile to update company info and see who's viewing your profile.
Etak Systems LLC Middletown
Quality
Alert*
Pro tip:
We generally recommend hiring a contractor with a score higher than 95.
*No active license on file. If you are Etak Systems LLC, click “This is My Business” to update your information.
Activity
|
4 projects
|
2025 |
|
6 projects
|
2024 |
|
10 projects
|
2023 |
Our building permit records indicate that Etak Systems LLC has worked on at least
20.0 projects over the past 3 years.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
This is an overview of this contractor's activity. Click here to access our complete licensing and building permit database.
Pricing
|
1 project
|
< $5k |
|
8 projects
|
$5k-$20k |
|
9 projects
|
$20k-$50k |
The typical size of their permits is approximately $20,000. This graph shows the distribution of these job values.
Pro tip:
For more details about their pricing, check out their recent activity to see how much they have charged for different types of work.
This is a sample of this contractor's permits. Click here to access their complete permit history.
Removal of existing ptac from shelter on grade. installation of new air handling unit and new condensing unit with wall repair for existing shelter on grade. one (1) ptac unit and one (1) dac unit to remain. no change to occupancy use or egress
Valuation:
$12,000
Permit #:
X00870772-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing units on roof. replacement of existing air handling units in existing equipment room in cellar. replacement of related lineset per plans. no change to occupancy use or egress
Valuation:
$20,000
Permit #:
M01017403-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing units on roof. replacement of existing air handling units in existing equipment room in basement. replacement of existing lineset per plans. no change to occupancy use or egress
Valuation:
$20,000
Permit #:
B01024669-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing unit on grade. replacement of existing air handling unit in existing equipment room on 4th floor. replacement of existing lineset per plans. no change to occupancy use or egress
Valuation:
$10,000
Permit #:
S01024707-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removal of condensing unit on grade. installation of new condensing unit on new steel dunnage on rooftop. replacement of air handling unit in equipment room on 1st floor. related condensate piping per plans. no change to occupancy use or egress
Valuation:
$25,000
Permit #:
M00593629-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing unit with mounting on grade. replacement of existing air handling unit with removal of ductwork patching of wall installation of damper and installation of dac on 1st floor. no change to occupancy use or egress
Valuation:
$25,000
Permit #:
B08051877-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing hvac system. replacement and relocation of condensing units on grade. replacement of air handling units in existing cellar equipment room. removal and installation of line sets per plans. no change to occupancy use or egress
Valuation:
$18,000
Permit #:
B00567294-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing units on roof. replacement of existing air handling units in existing equipment room on 6th floor. related mounting. no change to occupancy use or egress
Valuation:
$18,000
Permit #:
X01053834-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing units with related mounting modifications on roof. replacement of existing air handling units in existing equipment room in cellar. replacements of linesets per plan. no change to occupancy use or egress
Valuation:
$25,000
Permit #:
B00823063-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Modification to the existing hvac system as per plans (10074969 - at&t). no change to use egress or occupancy
Valuation:
$35,000
Permit #:
Q01074682-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing hvac system. installation of condensing units on roof. installation of related air handling units in existing equipment room in cellar. new lineset as per plan. no change to occupancy use or egress
Valuation:
$20,000
Permit #:
B00574156-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Application to obtain eup equipment use permit for dob completed application m00649858-i1. no change to use egress or occupancy. all in compliance with tppn 5/98. no proposed work in this application. please see attached ai1
Valuation:
$1
Permit #:
M00880033-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing unit on grade with related mounting. replacement of existing air handling unit in existing equipment room on 1st floor with related mounting. no change to occupancy use or egress
Valuation:
$10,000
Permit #:
M01053767-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
At&t - replacement of existing condensing units on the roof (10075235). no change to use egress or occupancy
Valuation:
$15,000
Permit #:
S01043339-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removal of existing condensing units. installation of new condensing units on existing shelter on grade. removal of existing air handlers in shelter. installation of new air handler and dac system in shelter on grade. no change to occupancy use or egress
Valuation:
$25,000
Permit #:
Q08023330-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing units on grade. replacement of existing air handling units in existing equipment room in cellar. replacement of existing line sets as per plans. related mounting per plans. no change to occupancy use or egress
Valuation:
$20,000
Permit #:
M00792713-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Removal of existing condensing unit and related steel on roof. replacement and installation of condensing units on grade. replacement and installation of related refrigerant lines as per plans. no change to occupancy use or egress
Valuation:
$35,000
Permit #:
Q00618312-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Modification at&t site. installing dac system with related louver. no change in use egress or occupancy. all in conformance with tppn 5/98
Valuation:
$15,000
Permit #:
M00408817-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of at&t (2) hvac & condensing units. no change to use egress or occupancy. paa to revise make model condenser units no change to quantities
Valuation:
$39,000
Permit #:
X00841337-I1-MS
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Replacement of existing condensing unit on grade with new roof curbs. replacement of existing air handling unit in existing equipment room in cellar. replacement of related condensate lines. no change to occupancy use or egress
Valuation:
$20,000
Permit #:
M00613167-I1-GC-CX
Status:
approved
Fee:
N/A
Permit Type:
N/A
Building Type:
N/A
Similar Contractors See more
147
BZ Score
$119K
Avg Project
-
Projects
154
BZ Score
-
Avg Project
-
Projects
162
BZ Score
$170
Avg Project
-
Projects
Etak Systems LLC Reviews
BuildZoom hasn't received any reviews for Etak Systems LLC. Click here to be alerted when reviews are posted about them.
Recent Buildzoom Projects
Etak Systems LLC License info
License Not Verified
| License # | 619213 |
| Status | Active |
| State | New York |
| Type | General Contractor Non Registered |
- When BuildZoom last verified this license, it had an expiration date of April, 2023. Check the current license status of Etak Systems LLC with the New York City Department of Buildings
This is a sample of licensing data; click here to access a complete history.
ALERT*
BuildZoom Score
- How the BuildZoom Score works
- *No active license on file. If you are Etak Systems LLC, click “This is My Business” to update your information.
Insured
| Insurer | Amco Insurance Co |
Insured
| Workers Comp Provider | Redwood Fire & Casualty |
35
Permits
- Building permit records show that Etak Systems LLC has worked on 35 permitted projects.